Henan Energy Electric Equipment Co., Ltd. was established in 2011 and is an excellent and reliable power equipment manufacturer in China. The company mainly develops and produces oil-immersed transformers, dry-type transformers, box-type substations, high-voltage switches, and medium and low voltage complete sets of equipment. The equipment put into production and operation of the project advocates energy saving, intelligence, informatization, and mechanization. The company has established the Henan Triangle Energy-saving Transformer Engineering Technology Research Center, with 71 utility model patents and 15 invention patents. With years of accumulation in the transformer industry and strong technological innovation capabilities, HZEC products are sold to the Middle East, North America, South America, Europe, Southeast Asia, Africa, and other regions, covering more than 40 countries.
The concept and principle of reactors
The reactor is a passive electronic component that is equally important as a capacitor and an inductor. Its function is similar to that of a capacitor, but it stores electromagnetic energy rather than electrical energy. It can adjust the voltage and current of the AC circuit to achieve the purpose of energy saving, voltage stabilization and noise reduction.
The principle of the reactor is based on the inductive properties of the steel core and coil, which realizes the adjustment of the circuit by hindering the speed and direction of the electronic flow. When the alternating current passes through the reactor, due to the change of the current in the circuit, an induction voltage perpendicular to the direction of the flow will be generated, thus adjusting the current in the circuit.
Product Application
XKGKL,,,.
XKGKL series current-limiting reactors are connected in series with the system circuit to strengthen the system impedance.Reduce the short-circuit current in case of malfunction with the system, which will lower the fault current to the allowable value.
Model Definition


Ordering Information
Nominal system voltage
Rated continuous current
Rated reactance rate
Rated reactance
Rated short-time current
Mode of installation (horizontal or vertical)
Working environment (indoors or outdoors)
Angle between inlet and outlet
Other special requirement
Product Standard
GB/T 1094.6-2011 IEC 60076-6:2007
GB/T 1094.1-2011 IEC 60076-1:2011
GB/T 1094.3-2017 IEC 60076-3:2013






Dry-type air-core current-limiting reactor 10kV
Part No. | Rated current A | Rated reactance rate | Rated reactance Ω | Short- time current kA | Single- phase power kvar | Single- phase loss75C kW | Overall dimension | Pitch diameter Dc mm | Weight (per phase) kg | Suggested arrangement mode | |
Ds mm | H mm | ||||||||||
XKGKL-10-800-5 | 800 | 5% | 0.361 | 16.00 | 230.9 | 4.6 | 1270 | 770 | 1170 | 350 | side by side |
XKGKL-10-800-8 | 8% | 0.577 | 10.00 | 369.5 | 5.7 | 1380 | 840 | 1280 | 420 | ||
XKGKL-10-800-10 | 10% | 0.722 | 8.00 | 461.9 | 6.5 | 1480 | 890 | 1380 | 490 | ||
XKGKL-10-800-12 | 12% | 0.866 | 6.67 | 554.3 | 7.7 | 1530 | 940 | 1430 | 547 | ||
XKGKL-10-1000-5 | 1000 | 5% | 0.289 | 20.00 | 288.7 | 6.0 | 1330 | 710 | 1240 | 370 | |
XKGKL-10-1000-8 | 8% | 0.462 | 12.50 | 461.9 | 7.2 | 1480 | 820 | 1380 | 530 | ||
XKGKL-10-1000-10 | 10% | 0.577 | 10.00 | 577.4 | 8.7 | 1670 | 760 | 1480 | 580 | ||
XKGKL-10-1000-12 | 12% | 0.693 | 8.33 | 692.8 | 9.8 | 1670 | 820 | 1480 | 630 | ||
XKGKL-10-1500-5 | 1500 | 5% | 0.192 | 30.00 | 433.0 | 8.1 | 1380 | 730 | 1200 | 477 | |
XKGKL-10-1500 8 | 8% | 0.308 | 18.75 | 692.8 | 9.4 | 1590 | 780 | 1320 | 662 | ||
XKGKL-10-1500-10 | 10% | 0.385 | 15.00 | 866.1 | 11.3 | 1590 | 850 | 1330 | 718 | ||
XKGKL-10-1500-12 | 12% | 0.462 | 12.50 | 1039.3 | 12.8 | 1700 | 880 | 1430 | 857 | ||
XKGKIA0-2000/5 | 2000 | 5% | 0.144 | 40.00 | 577.4 | 9.1 | 1710 | 600 | 1580 | 544 | |
XKGKL-10-2000-8 | 8% | 0.231 | 25.00 | 923.8 | 11.6 | 1770 | 700 | 1590 | 746 | ||
XKGKL-10-2000-10 | 10% | 0.289 | 20.00 | 1154.7 | 13.5 | 1870 | 730 | 1680 | 778 | ||
XKGKL-10-2000-12 | 12% | 0.346 | 16.67 | 1385.7 | 14.9 | 1860 | 800 | 1680 | 1000 | ||
XKGKL-10-2500-5 | 2500 | 5% | 0.115 | 50.00 | 721.7 | 10.2 | 1544 | 790 | 1280 | 678 | |
XKGKL-10-2500-8 | 8% | 0.185 | 31.25 | 1154.7 | 13.7 | 1600 | 960 | 1330 | 946 | ||
XKGKL-10-2500-10 | 10% | 0.231 | 25.00 | 1443.4 | 15.3 | 1740 | 980 | 1480 | 1085 | ||
XKGKL-10-2500-12 | 12% | 0.277 | 20.83 | 1732.1 | 18.1 | 1730 | 1000 | 1460 | 1200 | ||
XKGKL-10-3000-5 | 3000 | 5% | 0.096 | 60.00 | 866.0 | 11.2 | 1620 | 830 | 1440 | 733 | |
XKGKL-10-3000-8 | 8% | 0.154 | 37.50 | 1386.0 | 15.1 | 1720 | 930 | 1540 | 975 | ||
XKGKL-10-3000-10 | 10% | 0.192 | 30.00 | 1732.0 | 17.5 | 1750 | 1130 | 1650 | 1103 | ||
XKGKL-10-3000-12 | 12% | 0.231 | 25.00 | 2079.0 | 19.1 | 1760 | 1030 | 1500 | 1253 | ||
XKGKL-10-3500-5 | 3500 | 5% | 0.082 | 70.00 | 1010.0 | 12.7 | 1700 | 800 | 1440 | 980 | |
XKGKL-10-3500-8 | 8% | 0.132 | 43.75 | 1617.0 | 15.7 | 1820 | 880 | 1710 | 1322 | ||
XKGKL-10-3500-10 | 10% | 0.165 | 35.00 | 2021.0 | 18.9 | 1820 | 950 | 1710 | 1500 | ||
XKGKL-10-3500-12 | 12% | 0.198 | 29.17 | 2425.0 | 20.1 | 1820 | 1020 | 1710 | 1700 | ||
XKGKL-10-4000-5 | 4000 | 5% | 0.072 | 80.00 | 1155.0 | 12.1 | 1750 | 800 | 1640 | 1058 | |
XKGKL-10-4000 8 | 8% | 0.115 | 50.00 | 1848.0 | 17.8 | 1880 | 880 | 1700 | 1461 | ||
XKGKL-10-4000-10 | 10% | 0.144 | 40.00 | 2309.0 | 20.7 | 1970 | 880 | 1700 | 1687 | ||
XKGKL-10-4000-12 | 12% | 0.173 | 33.33 | 2771.0 | 22.6 | 2010 | 930 | 1740 | 1833 |
35kV series
Part No. | Rated current A | Rated reactance rate | Rated reactance Ω | Short- time current kA | Single- phase power kvar | Single- phase loss75C kW | Overall dimension | Pitch diameter Dc mm | Weight (per phase) kg | Suggested arrangement mode | |
Ds mm | H mm |
XKGKL-35-200-4 | 200 | 4% | 4.042 | 5.00 | 161 | 3.8 | 1590 | 600 | 1130 | 340 | side by side |
XKGKL-35-200-5 | 5% | 5.052 | 4.00 | 202 | 4.7 | 1640 | 630 | 1180 | 410 | ||
XKGKL-35-200-6 | 6% | 6.062 | 3.33 | 242 | 5.2 | 1700 | 630 | 1180 | 480 | ||
XKGKL-35-200-8 | 8% | 8.083 | 2.50 | 323 | 6.3 | 1760 | 650 | 1570 | 560 | ||
XKGKL-35-400-5 | 400 | 5% | 2.256 | 8.00 | 404 | 6.7 | 1780 | 730 | 1330 | 670 | |
XKGKL-35-400 8 | 8% | 4.042 | 5.00 | 646 | 8.4 | 1700 | 690 | 1510 | 880 | ||
XKGKL-35-400-10 | 10% | 5.052 | 4.00 | 808 | 9.6 | 2000 | 680 | 1810 | 970 | ||
XKGKL-35-400 12 | 12% | 6.062 | 3.33 | 970 | 10.7 | 2000 | 730 | 1810 | 1050 | ||
XKGKL-35-600-5 | 600 | 5% | 1.684 | 12.00 | 606 | 8.2 | 1680 | 650 | 1550 | 850 | |
XKGKL-35-600-8 | 8% | 2.694 | 7.50 | 970 | 10.5 | 1980 | 700 | 1790 | 1120 | ||
XKGKL-35-600-10 | 10% | 3.368 | 6.00 | 1212 | 12.9 | 1980 | 780 | 1790 | 1340 | ||
XKGKL-35-600-12 | 12% | 4.042 | 5.00 | 1454 | 13.8 | 2030 | 800 | 1840 | 1520 | ||
XKGKL-35-800-5 | 800 | 5% | 1.263 | 16.00 | 808 | 9.4 | 1800 | 650 | 1600 | 980 | |
XKGKL-35-800-8 | 8% | 2.021 | 10.00 | 1293 | 13.3 | 2100 | 650 | 1920 | 1420 | ||
XKGKL-35-800-10 | 10% | 2.526 | 8.00 | 1616 | 14.9 | 2100 | 830 | 1920 | 1650 | ||
XKGKL-35-800-12 | 12% | 3.031 | 6.67 | 1939 | 16.5 | 2100 | 760 | 1920 | 1720 | ||
XKGKL-35-1000-5 | 1000 | 5% | 1.010 | 20.00 | 1010 | 10.2 | 1670 | 700 | 1540 | 1270 | |
XKGKL-35-1000 8 | 8% | 1.617 | 12.50 | 1616 | 14.2 | 1870 | 800 | 1680 | 1620 | ||
XKGKL-35-1000-10 | 10% | 2.021 | 10.00 | 2020 | 16.9 | 1940 | 800 | 1750 | 1740 | ||
XKGKL-35-1000 12 | 12% | 2.425 | 8.33 | 2424 | 18.6 | 2070 | 880 | 1880 | 1870 | ||
XKGKL-35-1500-5 | 1500 | 5% | 0.674 | 30.00 | 1515 | 13.8 | 1700 | 750 | 1510 | 1550 | |
XKGKL-35-1500-8 | 8% | 1.078 | 18.75 | 2424 | 17.9 | 1820 | 800 | 1620 | 1910 | ||
XKGKL-35-1500-10 | 10% | 1.347 | 15.00 | 3031 | 20.7 | 1800 | 900 | 1600 | 2200 | ||
XKGKL-35-1500-12 | 12% | 1.617 | 12.50 | 3637 | 23.2 | 2300 | 900 | 2110 | 2380 |
The reactor is mainly used in the power system, to adjust the reactive power distribution in the system, reduce the power frequency voltage, and suppress the harmonic current and flicker. The following are some common applications:
2. In the motor system: the reactor can be used during the starting and braking of the motor to reduce the starting current and the impact current during the braking process. In addition, it can also be used to prevent the self-excited magnetic phenomenon of the motor under light or no-load.
3. In electronic equipment and communication systems: reactors can be used to suppress the high-order harmonic components in the power supply and reduce the impact on electronic equipment. For example, high-frequency reactors are used in switching power supplies, inverters, communication equipment, etc.

1.Our company provides you with project design and process design, and designs and manufactures products according to your equipment purchase plan and specific needs. And train technical and operating personnel for you.
2.The newly purchased products are provided with online assistance for installation and debugging. The products are under the lifelong service system. If problems occur in normal use, we will provide solutions within one working day after receiving user's feedback. We will try our best to get the product up and running as soon as possible. And there are regular visits by professional technicians to ensure the long-term, safe and reliable use of our products.
3.We use quality authentic materials, process and manufacture in strict compliance with ISO9001:2000 international quality management to ensure the quality of excellence and the smooth installation!