Dry-Type Transformer Three Phase Pouring Type Dry Transformer 2500kVA

Price $200000.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 452 people viewed
Quantity
+-
 

Shenda International Engineering Co., Ltd.

VIP   Audited Supplier 12 years
Profile Certified by SGS/BV
S9, S10, S11, S9-M, S10-M, S11-M, SG(B)10, SG(B)11
Power, Electronic, Instrument, Lighting, Rectifier, Audio
Three
Core-type Transformer
Dry-type Transformer
Two-winding Transformer
Power
Other
Sea Worthy Packing
Toroidal
Ctqc, CE, ISO9001, ISO14001, Cesi
EACHER
Sea Worthy Packing
CE, ROHS, SGS, GMP, CTQC, ISO, CESI
Zhejiang, China (Mainland)
Product Description
Specifications

Dry type transformer 1) Certificates:CTQC, ISO9001, ISO14001, CE 2) Apply for IEC, GB, ANSI 3) Up to 35kV, 2500kVA 4) Low losses

Application Of Products
Our SC(B) series epoxy resin cast dry transformer is cast under vacuum with thin insulating bands automatically.The core is made of high-permeable grain-orientated silicon sheet and cast with imported epoxy resin.Thanks to advanced technology, quality raw materials, scientific management, and perfect inspection means, our products have the following features:
The coil is reinforced with glass fiber and cast under vacuum with filler epoxy resin.It has good mechanical properties, is free of crack and inner bubble and has low local discharge, high reliability, and long service life.
The high-and low-voltage systems are cast under vacuum, thus the coil will not absorb moisture;The clamps of core are subjected to corrosion-resistant treatment and it may run under high temperature or other serious environments.
Flame retardancy, explosion-proof and no environmental contamination.The insulating materials in the coil such as glass fiber are self-extinguishing and they will not cause fire by the arc resulted from short-circuit.The resin will not generate toxic or harmful gas under high temperature.

Gas duct is embedded inside it to enhance the radiation power and over-load capacity.
Low loss and low noise.The core is lapped with 45 full-miter and the step-type lamination effectively improves distribution of magnetic flux at core corners, and greatly reduces the no-load loss and the nose level.
It highly withstands short-circuit and lightning impact.
Small in volume, light in weight, safe in running and free of maintenance.
As per users' requirements the transformer may be provided with casing and blower fan.
 Rated Power (kVA) High Voltage (kV) H.V. Tap Range Low Voltage (kV)Connection Symbol  Short-Circuit Impedance (%) No-Load Loss (W)  On-Load Loss (W)   No-Load Current  (%)Insulation Class Noise (dB) Weight (kg) Overall Dimension L*W*H  (mm)
 50 20/22/24  ±5%  or   ±2*5%0.4  Yyn0    Dyn11 6 340 12402.4  F 2.4560  1080*660*830
 100 20/22/24   ±5%  or   ±2*5%  0.4   Yyn0    Dyn11 6   540 20002.2    F 2.2 690 1160*760*900
160   20/22/24   ±5%  or   ±2*5%  0.4    Yyn0    Dyn11   6  680  24701.8  F   1.8 8101190*760*950 
 200  20/22/24   ±5%  or   ±2*5%  0.4   Yyn0    Dyn11 6   740 2950 1.8  F 1.8 1030 1200*760*990
 250  20/22/24   ±5%  or   ±2*5%  0.4   Yyn0    Dyn11  6 8503420  1.6  F 1.6 1280 1220*760*1160
 315  20/22/24   ±5%  or   ±2*5% 0.4    Yyn0    Dyn11    6970  40901.6   F 1.6 1530 1250*760*1210
 400  20/22/24   ±5%  or   ±2*5%  0.4   Yyn0    Dyn11 6   1150 4850 1.4  F 1.4 1660 1390*920*1470
 500  20/22/24   ±5%  or   ±2*5%  0.4  Yyn0    Dyn11    6 1350 58001.4  F  1.4  2010 1420*920*1360
 630  20/22/24   ±5%  or   ±2*5%  0.4   Yyn0    Dyn11  6 1530 68401.2   F 1.22390  1510*920*1460
 800  20/22/24   ±5%  or   ±2*5% 0.4     Yyn0    Dyn11  61760  8270 1.2  F1.2  3060 1660*920*1510
 1000  20/22/24   ±5%  or   ±2*5%  0.4  Yyn0    Dyn11    6 20709790  1.0  F 1.0 3410 1740*960*1660
 1250  20/22/24   ±5%  or   ±2*5% 0.4     Yyn0    Dyn11 6   2390 11540 1.0  F 1.0    40101930*960*1760 
 1600 20/22/24   ±5%  or   ±2*5% 0.4     Yyn0    Dyn11  6 2790 13870 1.0 F    1.0 5030 2040*960*1960
 2000  20/22/24   ±5%  or   ±2*5%  0.4   Yyn0    Dyn11  6 3240 16390 0.8  F 0.8 5980 2040*1255*2030
 2500  20/22/24   ±5%  or   ±2*5% 0.4    Yyn0    Dyn11    6 3870 19380 0.8 F   0.86160  2060*1255*2200
Certifications


Certificates owned by shenda:
100MVA/220kv power transformer short circuit test report
-issued by CESI Italy&CTQC China

120MVA/33KV oil EAF transformer
50MVA/69KV oil power transformer
10MVA/33kv dry-type transformer
Type test report
-issued by KEMA Netherlands

63MVA/110KV Power transformer short circuit test report
-issued by CTQC China

12.5MVA/22KV Rectifier transformer routine test
-issued by V-Check korea

ISO 9001&ISO14001&OHSAS 18001
CE-POWER TRANSFORMER&FURNACE TRANSFORMER&DRY-TYPE TRANSFORMER&REACTOR

Transformer Characteristics

Winding .
The winding must be especially protected - both against high electrical stress due to
external over voltages and against mechanical overloads by short circuits. They are made of copper or aluminum. Low-voltage windings are made of strip or flat wire while
high voltage windings are manufactured from round or profile wire. ("diamond-dotted paper") bonds the winding into a compact block
while drying and increases the short-circuit capacity additionally.


Magnetic Core lamination.
The three-limb iron core is made of oblique cut Grain-oriented, seven-step silicon steel lamination insulated on both sides,
guaranteeing low losses and low noise. These values are even improved by laser treatment. It is protected on the surface with a
flash-proof varnish in order to prevent the sheet from corrosion and to reduce the noise.


Oil tank.
Whether during transport or operation -the tank must be absolutely tight under mechanical stress. We have vast constructional experience, the most modern calculation methods and high-quality welding work. Special attention is paid to
corrosion protection. Pretreatment of the surface is processed by phosphating pickling, contributes to corrosion protection, just
like multi-coating with preset drying times for each layer. On request, hot-dip galvanization provides for even better protection


Test lab
Testing are conducted for every transformer before delivery.Tests are classified to be routine tests and type test.
A - Routine tests: According to IEC 60076 standard , the following tests must be carried out for all units of the transformers
a- Measurement of winding resistance .
b- Measurement of voltage ratio and check of phase displacement.
c- Measurement of short circuit impedance and load losses.
d-Measurement of no-load losses and current .
e-Dielectric routine tests including the separate source AC voltage withstanding test and short duration induced over voltage withstanding test ( ACSD ) .

B - Type tests :
The following tests shall be carried out
a- Temperature rise test
b- Lightning impulse test

C - Special tests :
a- Determination of noise level according to IEC 60551 .
b- Oil leakage test
c- Overload test at 150 % rated current for one hour after temperature rise test ( top oil temperature rise and winding temperature rise must be measured and recorded in the report test also hot spot temperature rise must be calculated and recorded on the report test ) .
d- Short Circuit Dynamic stability Test (test report from independent and accredited laboratory for similar transformer will be accepted).


Packaging and transportation



Company Introduction
SHENDA electric group is a manufacturer and wholesale company that manufactures good & high quality electric transformers from 2000. The company provides the customized products and OEM service. The factory own the 3 production base worldwide,2 in China and 1 in USA.We also own a transformer research institute with more than 30 electric engineers .

Our Services
1. Pre-Sale Service
- Quick response: reply you within 8 hours, to save your time.
- Professional solution: supply professional completed solution base on your technical requirements,  to complete your technical plan.
- Quoataion: submit a competive price within 2 days, to promote your business

2. In Sale Service
- Supplying stipulated completed drawings
- Supplying manufacturing plan and processing photos
- Making the test plan and book hotel for the witness person
- Making good arrangement of the delivery and shipment

3. Afer Sale Service
- Supplying professional supervision and commissioning within 15 days
- Training the workers
- Providing 12 months waranty of quality and perforance



RFQ
1,Q:
Are you manufacturer?
 
   A:
Yes, we are manufacturer. Our factory is in JiangShan City, zhejiang  Province.
 
2,Q:
What is your delivery time ? 
 
   A:
Depend on the type of transformer.
 
3,Q:
What is your payment term?
 
  A:
30% advance by T/T , 70% before delivery by T/T or L/C or we can discuss about it.
 
4,Q:
Are your transformers supported for customization ?
 
  A:
Yes, of course. We can design and produce accroding to the technical requirements and parameters of customers.
 
5,Q:
Do you offer guarantee for the products?
 
   A:
Yes. Different transformers is different. We offer at least one year guarantee for all of our transformers.
 
6,Q:
Do you accept Factory Acceptance Test?
 
   A:
Yes. It's available. And we are responsible for each set transformer's testing (ICE).
 
7,Q:
Do you assign engineer for after-sale service?
 
   A:
Yes. For our products,we all provide after-sale installation instructions service
 
 
Message Type