DMV5065/11ECO DC24-28V
Gas
-15 °c to +60 °c
Electric
Flange
Direct Acting
Stainless Steel
500 Mbar (50 Kpa)
Direct Action Diaphragm Structure
AC Solenoid Valve
Safety, Emptying, Drain, Temperature Control, Flow Control, Gas Burners Industrial Accessories
DIN
Industrial Usage, Water Industrial Usage, Household Usage, Industrial Gas Burners
Solenoid Valve
Dmv5065/11eco DC24-28V
Dungs
DC24-28V
500 Mbar (50 Kpa)
12kg
IP 54 / 100 %
< 1 S
-15 °c to +60 °c
Video Technical Support
Gas Burners Industrial Accessories
Dungs
Carton Box Packing
45X37X42 cm
Germany
8481100090
Product Description
Dungs DMV5065/11ECO DC24-28V 256297 DN65 Double High Pressure Gas Air Solenoid Valve Electromagnetic For Burner

Technology :
DUNGS gas multi-function combination regulator is tightly combined with filter, regulator, valve and pressure monitor. Dirt Depositor: Fine sieve One regulator and two valves: B01 - One stage valve, one second stage valve - One fast opening valve, one fast or slow opening valve Solenoid valve up to 360 mbar according to DIN EN 161 class A class 2 Sensitively adjustable with proportional regulators according to DIN EN 88 Class A class 2 - Output pressure -Achieves high flow values with low differential pressure - DC solenoid valve drive with interference degree N - Main flow restrictor and partial flow restrictor for valve V2 - Hydraulic opening hysteresis - Pipe threaded flange connection in accordance with ISO7/1 -Easy installation, small size and light weight By means of an external ignition gas tap connected to a separately regulated valve and by installing a valve detection system max/min pressure monitor with valve V2, Pressure limiters and end switches, this combined system offers special solutions.
DUNGS gas multi-function combination regulator is tightly combined with filter, regulator, valve and pressure monitor. Dirt Depositor: Fine sieve One regulator and two valves: B01 - One stage valve, one second stage valve - One fast opening valve, one fast or slow opening valve Solenoid valve up to 360 mbar according to DIN EN 161 class A class 2 Sensitively adjustable with proportional regulators according to DIN EN 88 Class A class 2 - Output pressure -Achieves high flow values with low differential pressure - DC solenoid valve drive with interference degree N - Main flow restrictor and partial flow restrictor for valve V2 - Hydraulic opening hysteresis - Pipe threaded flange connection in accordance with ISO7/1 -Easy installation, small size and light weight By means of an external ignition gas tap connected to a separately regulated valve and by installing a valve detection system max/min pressure monitor with valve V2, Pressure limiters and end switches, this combined system offers special solutions.

Application
Double solenoid valves are used where two single valves were mounted previously. In connection with DUNGSgas regulators and additional components, a wide variety of regulating tasks can be performed. It does not contain any non-ferrous metals, suitable for gases of up to max. 0.1 vol.% H2 S, dry. Suitable for gases of families 1, 2, 3 and other neutral gaseous media.
Approvals EC type test approval as per EC Gas Appliance Directive: DMV-…525-5125/11 eco CE-0085 AN 2801 EC type test approval as per EC Pressure Equipment Directive: DMV-…525-5125/11 eco CE0036 Approvals in other important gas consuming countries.
Approvals

DMV/11 eco
Two single stage solenoid valves, de-energised in absence of current, fast-opening, fast-closing.
DMV-D/11 eco Two
single stage solenoid valves, de-energised in absence of current, fast-opening, fast-closing. Manual limitation of gas flow is possible with main load adjustment (D) at valve 1 (V1).
single stage solenoid valves, de-energised in absence of current, fast-opening, fast-closing. Manual limitation of gas flow is possible with main load adjustment (D) at valve 1 (V1).
DMV-DLE/11 eco
Two single stage solenoid valves, de-energised in absence of current, slow-opening (L), fastclosing. Adjustment of opening time (E) with fast stroke range at valve 2 (V2). Manual limitation of gas flow is possible with main load adjustment (D) at valve 1 (V1).

item | value |
Warranty | 1.5 years |
Type | Kitchen Gas Shut-Off Valves, Emergency Shut-Off Valves, Truck Shut-Off Valves, AXIAL VALVES, Backwater Valves, Pressure Vacuum Breaker, Atmospheric Vacuum Breaker, Safety Relief Valves, Adjustable Relief Valves, Pressure Regulators, Boiler Feed Valves, VENT Valves, Mixing Valves, Temperature Regulating Valves, SOLENOID VALVES, Globe Valves, PLUG VALVES, Drain Valves, Air Valves & Vents, Faucet Valve, Flush Valves, REVERSING VALVE |
Customized support | OEM |
Place of Origin | Germany |
Brand Name | Dungs |
Model Number | DMV 5065/11 eco DC 24-28V |
Application | Gas Burner Accessories |
Power | Solenoid |
Media | Gas |
Port Size | DN 65 |
Structure | Plug |
Product name | Dungs DMV 5065/11 eco DC 24-28V 256296 DN65 GAS Solenoid Control Valves |
Model | DMV 5065/11 eco DC 24-28V |
Brand | Dungs |
Power Supply | 250 V AC,50 - 60 Hz, |
Max. operating pressure | 500 mbar (50 kPa) |
Ambient temperature | -15 °C to +60 °C |
Closing time | < 1 s |
Color | Grey And Sliver |
After Warranty Service | Video technical support |
Usage | Gas Burner Accessories |
Dungs DMV5065/11ECO DC24-28V 256297 DN65 Double High Pressure Gas Air Solenoid Valve Electromagnetic For Burner