Material(s) Description
Warp material: Polyester
Weft material: Irradiated, modified polyolefin
Coating: Modified polyolefin
Operating temperature range (3000 hours): -40°C to 125°C
Operating temperature range (1000 hours): -40°C to 150°C
Minimum recovery temperature: 110°C
Recommended recovery temperature :150°C to 200°C
Maximum storage temperature: 50°C 
Standard:TL52668    TL52361    D44 1959   GMW14327
Testing organization:CTI  PONY

Product description   (CL-KSD)Inside diameter (mm)
 D (min.) expanded as supplied d (max.) recovered after heating
φ6/3-B63
φ8/4-B84
φ10/5-B105
φ12/6-B126
φ16/8-B168
φ20/10-B2010
φ25/12-B2512
φ30/15-B3015
φ35/17.5-B3517.5
φ40/20-B4020
φ50/25-B5025
φ60/30-B6030
φ70/35-B7035
φ80/40-B8040
φ100/50-B10050
B:black
Other specifications can be customized

 

PropertyTest condition(s)Performance
Thermal ageing168 hrs at 125°CNo deterioration in abrasion resistance at 23°C
24 hrs at 125°CNo deterioration in abrasion resistance at 23°C
FlammabilityMVSS 302Burning rate≤100 mm/min
Low temperature flexibility 4 hours at -40°C,10X  diameter mandrelNo cracking
Abrasion resistance
(1.5N load, 0.3mm radius metal blade,60 cpm,50mm stroke, 144 000 cycles)
 
Environmental Chamber Temperature: -35°C No wear to underlying rubber hose
Environmental Chamber Temperature: 140ºC
Temperature resistance
1) Test temperature 140 ºC, for 500 hours
2) Remove the sample and cool it to room temperature..Then place the sample at -35°C for 22 hours.
3) Then bend the sample 180 degrees around a cylinder with a radius of 30mm
Test temperature 140 ºC, for 500 hours
 
The protection tube is not damaged
Standard: TL52668











 

 