FKS-Y300
Global
1000 Hours or 1 Year
Basic Diesel Generator
Fixed
Four Stroke
Water Cooling
AC Three Phase
HSS
Land Use
Common Units, Standby Unit, Emergency Crew
Low Noise
AC Rotating Exciter
Diesel
<2700 Asl
Yuchai
Dynamic
Container
China
85021100
Product Description
Diesel GeneratorTechnical Parameters
Unit model | FKS-Y300 |
Power (KW) | 300 |
Rated voltage (v) | 440 |
Rated current (A) | 492 |
Rated frequency (Hz) | 60 |
Rated speedr/min | 1800 |
Speed control system | Electronic speed |
Power factor | 0.8 |
No-load voltage distortion (≤%) | 3% |
Steady-state voltage deviation (≤%) | 0.5% |
Transient voltage deviation (≤%) | +20% ~ -15% |
Voltage stabilization time (s) | 5.0S |
Voltage regulation (≤%) | 0.5% |
Frequency drop(≤%) | 3% |
Transient frequency deviation (≤%) | +10% ~ -7% |
Frequency recovery time (s) | 5.0S |
Steady-state frequency (≤%) | 0.5% |
Alarm temperature | 95ºC |
Shut down temperature | 102ºC |
Standard atmospheric conditions | GB1105, ISO3046 |
Atmospheric pressure | 100Kpa(altitude400m) |
Ambient temperature (ºC) | 40 |
Relative humidity (%) | 80 |