EH
AC
3
3
380V
80A, 90A, 120A, 145A, 185A, 210A, up to 800A00A
Ac Contactors
IEC947
40kw, 45kw, 55kw, 75kw, 90kw, up to 400kw
3no
2no+2nc, 4no+4nc
as Per Customer's Requirement
Own brand
Carton
Please refer to the attachment
China
8536490090
Product Description
EH series of AC contactorsEH series AC contactors is mainly used in the electric power circuit of AC 50Hz or 60HZ, rated voltage to 660V, current to 880A for making and breaking circuit. and It can be formed into motor starter with thermal relay or electronic protector for protecting from overload circuit.
Model: EH80, EH90, EH100, EH145, EH175, EH210, EH260, EH300, EH370, EH450, EH550, EH700, EH800, EH1200
3NO main contact (power contact)
Auxiliary contact: 1NO, or 1NC, or 1NO+1NC, or 2NO+2NC, 4NO+4NC.




Model: EH80, EH90, EH100, EH145, EH175, EH210, EH260, EH300, EH370, EH450, EH550, EH700, EH800, EH1200
3NO main contact (power contact)
Auxiliary contact: 1NO, or 1NC, or 1NO+1NC, or 2NO+2NC, 4NO+4NC.
EH | 80 | 90 | 100 | 145 | 175 | 210 | 260 | 300 | 370 | 550 | 700 | 800 | ||
Ui (V) | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | 690 | ||
Ith (A) | 145 | 160 | 200 | 230 | 260 | 300 | 400 | 445 | 550 | 800 | 1000 | 1000 | ||
Ue (V) | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | 220 | ||
380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | 380 | |||
660 | 660 | 660 | 660 | 660 | 660 | 660 | 660 | 660 | 660 | 660 | 660 | |||
Rated current Ie (A) Under interrupted duty | AC-1 | 145 | 160 | 200 | 230 | 260 | 300 | 400 | 445 | 550 | 800 | 1000 | 1000 | |
AC-3 | 220V | 80 | 90 | 120 | 145 | 185 | 210 | 260 | 305 | 400 | 550 | 700 | 750 | |
380V | 80 | 90 | 120 | 145 | 185 | 210 | 260 | 305 | 400 | 550 | 700 | 750 | ||
660V | 65 | 70 | 120 | 120 | 170 | 210 | 250 | 280 | 370 | 550 | 700 | 750 | ||
AC-4 | 220V | 80 | 80 | 117 | 125 | 146 | 175 | 250 | 250 | 350 | 450 | 630 | 630 | |
380V | 80 | 80 | 117 | 125 | 146 | 175 | 250 | 250 | 350 | 450 | 630 | 630 | ||
660V | 30 | 35 | 47 | 55 | 66 | 75 | 95 | 95 | 117 | 140 | 185 | 185 | ||
Controlled motor power, AC-3 (KW) | 220V | 22 | 22 | 30 | 45 | 55 | 59 | 80 | 90 | 110 | 160 | 220 | 220 | |
380V | 40 | 45 | 55 | 75 | 90 | 110 | 140 | 160 | 200 | 280 | 370 | 400 | ||
660V | 45 | 59 | 110 | 110 | 132 | 160 | 200 | 250 | 355 | 500 | 600 | 650 | ||
Rated current Ie (A) Under non-interrupted duty | 145 | 160 | 200 | 230 | 260 | 300 | 400 | 445 | 550 | 800 | 1000 | 1000 | ||
Winding power(VA) | keep | 22 | 35 | 40 | 45 | 130 | 130 | |||||||
Close | 360 | 570 | 800 | 1050 | 2100 | 3160 |