Eaton 93E UPS
Three Phase
On-line
Short Circuit
Communication
Lighting/Power
Standard Machine
Sine Wave Output UPS
Large Type
Decentralized/Centralized Model
Eaton
100kVA-500kVA
380VAC/220VAC
Tower UPS
50/60Hz
55-73dB
3:01
98%
0~40ºC
-25~55ºC
380VAC/220VAC
380VAC/220VAC
380VAC
VRLA, AGM, Gel Batteries, or Eaton Lithium Batteri
8 Hours to Reach 90% of Full Capacity
RS-232, Mini-Slot Communication Slot
Eaton
China
8504402000
Product Description

TECHNICAL SPECIFICATIONS1 | ||
Power | ||
Ratings | 80kVA/72kW, 100kVA/90kW, 120kVA/108kW 160kVA/144kW, 200kVA/180kW 300kVA/270kW, 400kVA/360kW | |
Topology | Double-conversion online UPS | |
Electrical Input | 400/230V,4 wire (380/415V selectable) | |
Input Voltage Range | -15%, +20% from nominal (400V) at 100% load without depleting battery | |
Operating Frequency | 50/60 Hz(40 to 72 Hz) | |
Input Power Factor | >0.99 typical | |
Input Current Distortion | ≤5%THD | |
Electrical output | ||
Nominal Output Voltage | 400/230,4 wire (380/415V selectable) | |
Output Voltage Regulation | ±1% Static;±5% dynamic at 100% resistive Load change,<20 ms response time | |
Battery | ||
Battery | 216/240 Cells (Selectable) | |
Charging Method | ABM Cyclic Charging | |
General | ||
Efficiency | Up to 98.5%High-efficiency mode Up to 94%Double-conversion mode | |
UPS Bypass | Automatic on overload or UPS failure | |
Dimensions Wx Dx H | 600x800x1876(mm)80-200kVA 1600x820x1880(mm)300/400kVA | |
Cabinet rating | P20 with standard washable dust filters | |
Weights | 80/100kVA-283 kg,120kVA-311 kg 160/200kVA-457 kg.300/400kVA-1090 kg | |
Overload | 150%for 1 minute,125%for 10 minutes >150%for 150ms | |
Communications | ||
Display | Graphical LCD with blue backlight | |
LEDs | (4)LEDs for notice and alarm | |
Audible Alams | Yes | |
Communication Ports | (1)RS-232,(1)USB,(1)EPO | |
Communication Slot | (2)Mini-slot communication bays | |
Environmental | ||
Operating Temperature | 0ºCto+40ºC; Batteries recommended max.+25ºC | |
Storage Temperature | -25ºC to +55ºC without batteries +15ºC to+25ºC with batteries | |
Relative Humidity | 5-95%,non-condensing | |
Audible Noise | 80-120kVA≤65 dBA at 1m typica 160-200kVA≤70 dBA at 1m typica 400kVA≤73 dBA at 1m typica | |
Altitude | <1000m at+40ºC | |
Certifications | ||
EMI Standards | EN55022/EN55024 | |
FMC Compliance | EC 62040-2 | |
Quality | S09001:2000 and ISO 14001:1996 | |
Accessories | ||
Top Cable Entry (80-200kVA,standard on 300-400kVA | ||
Maintenance Bypass Switches and System Parallel Modules | ||
Battery Cabinets &Battery Circuit Breakers,IP21 hood (80-200kVA) |













Yes, we can offer sample testing for you to verify product quality and performance.
2. What is the warranty?
We support 1 years warranty.
3.What can you buy from us?
Eaton, Vertiv, APC, Santak, Vesion & OEM/ODM UPS; Cooling, MDC, PDU and so on.
4. What payment methods does your conmpany support?
We could accept T/T, credit card, Alipay or L/C at sight.
5. What are the terms can you offer for us?
We could offer EXW, FOB, CIF, DDP and so on.