Electricity Acquisition and Control Terminal

Price $100.00 Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 356 people viewed
Quantity
+-
 

Nanjing Linkelec Technology Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
LINK913T
Two Years
Two Years
Digital
Direct Connected
Three-phase Four-wire
Electronic Meter
Feed-through Type
Energy Meter
ISO
Customized
Linkelec
Carton
Made in China
90283012
Product Description
                                          Three phase intelligent color screen terminal electric meter
 
Product profile
Intelligent full-color digital power instrument is a new generation of intelligent digital power grid front-end acquis ition device of our company, which is widely used in various power distribution Internet of Things sys tems. This terminal has high-precis ion measurement and comprehensive power quality monitoring functions. It has thecharacteristics of convenient installation, simple wiring, convenient maintenance, small engineering quantity, and can flexibly network with all kinds of communication software. All electrical parameters in the power grid can be measured, and data is exchanged with the system platform through communication.

LINK913T Product advantages
Users can flexibly set the internal parameters of the product according to the actual situation on the site, with complete functions and integrate various measurement parameters, power quality parameters, temperature, zero order, etc. The structural modular design can be easily installed in various distribution boxes. It is a comprehensive power monitoring device.
 
 
Qualification
 Performance Parameter 
Performance Index 
Accuracy Class U, I: 0.2;   P, Q, PF: 0.5;   F: ± 0.01 HZ;   Active Power: 0.5S;   Reactive Power: 2
Display ModeTFT Show
Mode Of Connection Three phase three wire, Three phase four wire
Rated Voltage AC57.5V,AC100V,AC400V,AC690V
Frequency Range 45~65Hz
Overload Capacity1.2Un (continuous); 2Un (10s allowed)
Measuring Range 5V~1.2Un
Functional ConsumptionAnd 0.1VA per phase
Rated Current AC1A ,AC5A
Frequency Range 1.2In (continuous); 20In (allowed 1S)
Overload Capacity5 mA to 6 A (Rated 5A);1mA~1.2A (rated 1A)
Measuring Range And 0.2VA per phase
Operating Voltage RangeAC/DC 85V~265V
Interface FormRs 485, Radio frequency (optional)
Protocol The Modbus-RTU, DL 645, et al
Working Temperature Ambient temperature: 25ºC ~70ºC, relative humidity: 95%, no corrosive gas site, altitude of 2500m
Storage Temperature -35ºC~80ºC
High * Wide * Deep100mm*100mm*67.5mm
Open Hole Size90±0.5mm*90±0.5mm
Way To InstallGuide rail installation and embedded installation

Selection specifications
functional moduleSerial numberFunction pointsFunction point descriptionElectricity measurement and control terminal
Real-time measurement1Phase voltagePhase voltage:Ua,Ub,Uc
2Line voltageLine voltage:Uab,Ubc,Uca
3Voltage sequence componentVoltage sequence component:U1,U2,U0
4Phase currentPhase current:Ia,Ib,Ic
5Current sequence componentCurrent sequence component:I1,I2,I0
6Active powerActive power:Pa,Pb,Pc,P
7Reactive powerReactive power:Qa,Qb,Qc,Q
8Apparent powerApparent power:Sa,Sb,Sc,S
9Power factor Power factor :Pfa,Pfb,Pfc,Pf
10PhaseVoltage/Current:∠Ua,∠Ub,∠Uc,∠Ia,∠Ib,∠Ic
11FrequencySystem frequency:F
Electricity metering12Active energyBidirectional active power of phase separation and phase combination
13Reactive powerPhase separated and combined bidirectional reactive power
14Apparent electrical degreePhase separation and combination are considered as electrical energy
Frozen15Monthly freezeThe monthly freeze date can be set from 1st to 28th, and the electric energy of the current month will be automatically recorded at midnight on each set date. It can record for 36 consecutive months
16Daily freezeCan be frozen continuously for 365 days, with cyclic coverage
17Freeze by hourCan be frozen continuously for 31 days and 744 hours, with cyclic coverage
Graphic display18Historical electricity consumptionHourly, daily, and monthly historical electricity consumption bar chart
19Total active powerTrend chart, capable of recording historical waveforms of data for 31 days
20Positive active energyPie chart, for 12 consecutive months
Power quality21Harmonic contentThe harmonic content of three-phase voltage and current is 2-31 times
22Harmonic distortion rateTotal, odd, and even harmonic distortion rates
23Out-off-balanceVoltage and current imbalance
24crest factor Peak coefficient of three-phase voltage
25Telephone harmonic factorTelephone harmonic factor THF
26K coefficientThree phase current K coefficient
27Frequency deviationSystem frequency deviation
Remote signaling28Entering and exitingHaving remote signaling status for input and output
29Over limit alarmHas a remote signaling status of level 8 over limit alarm
Exceed the time limit30Over limit alarmLevel 8 over limit alarm function, capable of monitoring power parameters and remote signals, generating alarms when conditions are met, and can be linked with the output for alarm export linkage
Event record31SOE recordIt has 64 SOE record functions, including switch displacement, remote control, over limit alarm, etc., and is accompanied by time stamp records
32Maximum value recordCapable of real-time statistics of the maximum and minimum values of relevant parameters (phase/line voltage, current, active power, reactive power, apparent power, power factor, frequency, demand), and recording them with time stamps
Clock33ClockEquipped with hardware precision clock
Input/Output34Switching input2-channel switch input, selectable as active node input
35Switching output2-channel switch output, supports level/pulse type, supports remote control or serves as a local over limit alarm outlet
36Pulse outputEquipped with an active power pulse output port, used for accuracy detection of electric energy meters
Communication interface 37RS485 communicationStandard configuration includes 1 RS485 communication channel, supporting MODBUS-RTU protocol; Support online program upgrade through RS485 interface
38Wireless Radio FrequencySupport wireless communication
Current transformer39Small current transformer5/2.5mA, equipped with 3 small current transformers
Note: Blank indicates that this function is not available, "√" indicates that this function is standard, and "○" indicates that this function is optional                                                                                                                                                                                        

Product installation and schematic diagram

Solution


About our service           
*  We could provide 7* 24-hour phone call after-sales service. 
*  We provide a 2-year guarantee time and will change the meter for you within 1 year if there's something wrong with the product. Except for natural disasters or man-made reasons.
*  Recommend the most advanced application technology and management model in the industry to customers, and provide customers with detailed solutions.


Package and ship
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA