Electrochemical Workstation Potentiostat Galvanostat with Eis Model CS310m

Price $5400.00 Compare
Min Order 1 set
Shipping From Hubei, China
Popularity 478 people viewed
Quantity
+-
 

Wuhan Corrtest Instruments Corp., Ltd.

VIP   Audited Supplier 7 years
Profile Certified by SGS/BV
CS310M
Free
3 Years
Customized
Desktop
CE, ISO
School, Hospital, Lab
Measurement Type
Wuhan Corrtest Instruments
±2A
±10V
Yes
10μHz~1MHz
CV, Lsv, Eis, Tafel, Charge and Discharge, etc
Support 2, 3, 4, 5-Electrodes System
Corrtest
Standard Carton
36*30*16 cm
China
9027899090
Product Description
Model CS310M EIS potentiostat /galvanostat / electrochemical workstation consists of DDS arbitrary function generator, high power potentiostat/galvanostat, dual-channel correlation analyzer, dual-channel high-speed 16bit/high-precision 24bit AD converter and extension interfaces. Max. current is ±2A, potential range is ±10V. EIS frequency range is 10uHz~1MHz. It can be used for various electrochemical fields such as corrosion, energy, material and electroanalysis. The current can be boosted up to 20A/40A with a current booster CS2020B/ CS2040B.


Applications
- Study of Energy materials (Li-ion battery, solar cell, fuel cell, supercapacitors), advanced functional materials
- Electrocatalysis (HER, OER, ORR, CO2RR, NRR)
- Corrosion study and corrosion resistance evaluation of metals; quick evaluation of corrosion inhibitors, coatings, and cathodic protection efficiency
- Electrosynthesis, electroplating/electrodeposition, anode oxidation, electrolysis


Specifications
 
Specifications
Support 2-, 3- or 4-electrode systemPotential and current range: Automatic
Potential control range: ±10VCurrent control range: ±2A
Potential control accuracy: 0.1%×full range±1mVCurrent control accuracy: 0.1%×full range
Potential resolution: 10μV (>100Hz),3μV (<10Hz)Current sensitivity:1pA
Rise time: <1μS (<10mA), <10μS (<2A)Reference electrode input impedance:1012Ω||20pF
Current range: 2nA~2A, 10 rangesCompliance voltage: ±21V
Maximum current output: 2ACV and LSV scan rate: 0.001mV~10,000V/s
CA and CC pulse width: 0.0001~65,000sCurrent increment during scan: 1mA@1A/ms
Potential increment during scan: 0.076mV@1V/msSWV frequency: 0.001~100 kHz
DPV and NPV pulse width: 0.0001~1000sAD data acquisition:16bit@1 MHz,20bit@1 kHz
DA Resolution:16bit, setup time:1μsMinimum potential increment in CV: 0.075mV
IMP frequency: 10μHz~1MHzLow-pass filters: covering 8-decade
Operating System: Windows10/11 Interface: USB 2.0
Weight / Measurements: 6.5kg, 36.5 x 30.5 x16 cm
EIS (Electrochemical Impedance Spectroscopy)
Signal generator
Frequency range:10μHz~1MHzAC amplitude:1mV~2500mV
DC Bias: -10~+10VOutput impedance: 50Ω
Waveform: sine wave, triangular wave and square waveWave distortion: <1%
Scanning mode: logarithmic/linear, increase/decrease
Signal analyzer
Integral time: minimum:10ms or the longest time of a cycleMaximum:106 cycles or 105s
Measurement delay: 0~105s
DC offset compensation
Potential automatic compensation range: -10V~+10VCurrent compensation range: -1A~+1A
Bandwidth: 8-decade frequency range, automatic and manual setting

Techniques- Model CS310M
 The comparison of the models among single-channel potentiostat: 
 
TechniquesCS300MCS310MCS350M
w/o EISwith EISwith EIS
Stable
polarization
Open Circuit Potential (OCP)
Potentiostatic (I-T curve)
Galvanostatic
Potentiodynamic(Tafel plot)
Galvanodynamic
Transient
polarization
Multi-Potential Steps
Multi-Current Steps
Potential Stair-Step (VSTEP)
Galvanic Stair-Step (ISTEP)
Chrono
methods
Chronopotentiometry (CP)
Chronoamperometry (CA)
Chronocoulometry (CC)
VoltammetryCyclic Voltammetry (CV)
Linear Sweep Voltammetry (LSV)(I-V)
Staircase Voltammetry (SCV) # 
Square wave voltammetry (SWV) # 
Differential Pulse Voltammetry (DPV)#  
Normal Pulse Voltammetry (NPV)#  
Differential Normal Pulse Voltammetry (DNPV)#  
AC voltammetry (ACV) # 
2nd Harmonic A.C.Voltammetry (SHACV) 
AmperometryDifferential Pulse Amperometry (DPA)  
Double Differential Pulse Amperometry (DDPA)  
Triple Pulse Amperometry (TPA)  
Integrated Pulse Amperometric Detection (IPAD)  
EISPotentiostatic EIS (Nyquist, Bode) 
Galvanostatic EIS 
Potentiostatic EIS (Optional freq.) 
Galvanostatic EIS(Optional freq.) 
Mott-Schottky 
Potentiostatic EIS vs. Time (Single freq.) 
Galvanostatic EIS vs. Time (Single freq.) 
Corrosion
 test
Cyclic polarization curve (CPP)
Linear polarization curve (LPR)
Electrochemical Potentiokinetic Reactivation (EPR)
Electrochemical Noise (EN)
Zero resistance Ammeter (ZRA)
Battery testBattery charge and discharge
Galvanostatic charge and discharge (GCD)
Potentiostatic Charging and Discharging(PCD)
Potentiostatic Intermittent Titration Technique(PITT)
Galvanostatic Intermittent Titration Technique(GITT)


SOFTWARE FEATURES
Cyclic voltammetry: CS studio software provides users a versatile smoothing/differential/ integration kit, which can complete the calculation of peak height, peak area and peak potential of CV curves. In CV technique, during the data analysis, there is function of selecting exact cycle(s) to show. You can choose to see a cycle or some cycles as you want. You can also export data or vector graph of an exact cycle or several cycles.


Tafel plot and corrosion rate:

Corrtest potentiostat includes all the electrochemical techniques for corrosion measurement such as OCP, polarization curve (potentiodynamic), EIS, Cyclic polarization CPP (passivation curve), Electrochemical Potentiokinetic Reactivation (EPR), Hydrogen diffusion test, ZRA, Electrochemical noise, etc. It can be used to study metal corrosion mechanism and corrosion resistance, and evaluate the coating durability and sacrificial anode current efficiency. It can also be used for rapid screening of corrosion inhibitors, fungicides, etc.

Battery Test and analysis:
With techniques LSV, CV, galvanostatic charge and discharge (GCD), Constant potential/ current EIS, and precise IR compensation circuit, Corrtest potentiostats are widely used in supercapacitor, Li-ion batteries, sodium-ion batteries, fuel cell, Li-S batteries, solar cell, solid-state batteries, flow batteries, metal-air batteries etc. It is an excellent scientific tool for researchers in the fields of energy and materials. 



EIS analysis: Bode, Nyquist, Mott-Schottky plot
During EIS data analysis, there is built-in fitting function to draw the custom equivalent circuit.


Real time saving of data:
The data can be automatically saved even in case of sudden power off.


Combination test: it can facilitate the automation of experiments and save time. With the unique function of combination test, you can choose several techniques, and set the wait time, the start time, and the cycles. Choose the experiments you want to run. Then you can make auto measurement of the set experiments as you want without having to wait in the lab. This function is especially useful if you have multi experiments to run and save your time greatly.
Combination Test: corrosion tests

Combination Test: Pseudo capacitor tests

Data open: You can open the data files by txt format in notepad. Data can also be opened in Origin

TECHNICAL ADVANTAGES
1. Impedance (EIS)
CS310M EIS potentiostat applies correlation integral algorithm and dual-channel over-sampling technique, and has strong anti-interference ability. It is suitable for EIS measurements of high-impedance system (>109Ω, such as coating, concrete etc.). It can also be used to obtain Mott-Schottky curve and differential capacitance curve. During test, the software can display real-time open circuit potential (OCP) without entering.
EIS of AA6063 Al alloy in Ce3+ containing 3% NaCl solution

2. Polarization curve
It can complete linear polarization curve and Tafel plot measurements. The user can set the anodic reversal current (passivation film breakdown current) of the cyclic polarization curve to determine material's pitting potential and protection potential and evaluate the its susceptibility to intergranular corrosion. The software employs non-linear fitting to analyze polarization curve, and can make fast evaluation of material's anti-corrosion ability and inhibitors.


Polarization curves of Ti-alloy & stainless steel in 3%NaCl solution

3. Voltammetry
It can do the following electroanalysis methods: Linear Sweep Voltammetry (LSV), Cyclic Voltammetry(CV).It integrates calculation of peak area, peak current and standard curve analysis.


LSV curve: mesoporous carbon material in 0.1M KOH

CV curves of PPy supercapacitor in 0.5 mol/L H2SO4

4. Electrochemical Noise
With high-resistance follower and zero-resistance ammeter, it measures the natural potential/current fluctuations in corrosion system. It can be used to study pitting corrosion, galvanic corrosion, crevice corrosion, and stress corrosion cracking etc. Through noise spectrum, we can evaluate the inducement, growth and death of metastable pitting and crack. Based on calculation of noise resistance and pitting index, it can complete localized corrosion monitoring.
Electrochemical noise of low-carbon steel in 0.05mol/L Cl-+0.1mol/L NaHCO3

5. Full floating measurement
CS310M potentiostat /galvanostat is designed as full-floating, and can be used for electrochemical study of working electrode connecting to earth, such as autoclave, metal part in bridge, concrete


6. Software development kit (SDK)
  We can provide secondary development interfaces,API general interfaces and development examples, and can realize data call for Labview, C, C++, C#, VC and other program, which is convenient for secondary development and test methods customization.

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA