GF102
24 Hour Service
3 Years
Digital
Direct Connected
Multi-Functional Energy Meter, Watt-Hour Meter, Meter for Industry and Home Use, Standard Electric Energy Meter, Prepayment Meter, Reactive Energy Meter, Multi-rate Watt-hour Meters, Maximum Demand Meter
Single-phase
Electronic Meter
Feed-through Type
Pulse Peak
Energy Meter
ISO, CE
Customized
0.1%, 0.2%
220V±10% 50/60Hz±2Hz
0-300V
Max. 30va, 15va
0.02%/120s, 0.05%/120s
<0.3% for Linear Resistance Load
1mA-100A, 1mA-60A
Max. 100va, 30va
45-70Hz
Max. 100kHz
GFUVE
Standard Export Box
445X440X180 (three meter positons)
Beijing, China
Product Description
GF102 meter test equipment mte ag bench suppliers manufacturers in europe
GF102 meter test equipment mte ag bench suppliers manufacturers in europe used to test single phase energy meter. Adopt mature signal synthetic and power amplifier technology, high precision voltage and current output. Widely used in lab and field, and then as single phase standard source.
Features
1. Meter under testing: 1P2W.
2. Testing mode: active power, reactive power.
3. Test 3pcs or 2pcs meter synchronously.
4. Start testing and creep testing.
5. Reference standard and power source integrated, easy to carry.
6. Measuring mechanical meter and electric meter.
7. Operating by manual keyboard or PC software.
8. With keyboard shortcuts.
9. Internal large capacity storage device for mass memory.
10. Local checking the testing result.
11. Overload, short circuit, open circuit protection.
12. With self-checking function.
Electrical parameters | |
---|---|
Accuracy class | 0.05%, 0.1% |
Power supply | One Phase AC 100-265V, frequency 50/60Hz. |
AC Voltage Output | |
Range | 57.7V, 100V, 220V, 380V; max 500V |
Adjustment range | (0-120)%RG(1) |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | 0.01%/120s |
Distortion | 0.1% (Non-capacitive load) |
Output load | max 25VA |
Measuring accuracy | 0.05%RG |
AC Current Output | |
Range | 200mA, 1A, 5A, 20A, 100A; max 120A |
Adjustment range | (0-120)%RG |
Adjustment fineness | 0.01%RG, 0.1%RG, 1%RG, 10%RG as optional. |
Stability | <0.01%/120s |
Distortion | ≤0.1% (Non-capacitive load) |
Output load | max 50VA |
Accuracy | 0.05%RG |
Power Output | |
Active power output stability | <0.01%RG/120s |
Reactive power output stability | <0.02%RG/120s |
Active power measuring accuracy | 0.05%RG |
Reactive power measuring accuracy | 0.1%RG |
Phase Output | |
Output adjustment range | 0°-359.999° |
Output adjustment fineness | 10, 1, 0.1, 0.01 as optional. |
Resolution | 0.01° |
Accuracy | 0.05° |
Power Factor | |
Adjustment range | -1 ~ 0 ~ 1 |
Resolution | 0.0001 |
Measurement accuracy | 0. 0005 |
Frequency Output | |
Adjustment range | 40Hz-70Hz |
Output adjustment fineness | 5Hz, 1Hz, 0.1Hz, 0.01Hz as optional. |
Resolution | 0.001Hz |
Accuracy | 0.005Hz |
Voltage /Current/Harmonic Setting | |
Harmonic number | 2-51times |
Harmonic content | 0-40% |
Harmonic phase | 0-359.99 |
Harmonic setting accuracy | (10%±0.1%)RD(2) |
Power Energy Measurement Error | |
Active power energy | 0.05%RG |
Reactive power energy | 0.1%RG |
Power Pulse Output | |
Power pulse type | active pulse, reactive pulse |
Active power pulse output | 5V,10mA |
Power Pulse Input | |
Energy pulse type | support active and reactive pulse, the highest frequency power pulse input is 180K. |
Mechanical parameters | |
Dimensions (W×D×H) (mm) | 455x440x150 |
Weight (kg) | 12 |
Environmental conditions | |
Ambient temperature | -10°C to +40°C |
Relative humidity | 35%-85% |
(1)RG means range, the same as below; (2)RD means the setted harmonic content, harmonic can be a single output,also multiple output. |