TPAS-040ASH
Air-Cooled
Air-cooled
Integral
380V/50HZ
2
Low
Heating and Cooling
Combination machine
RoHS, ISO, CE
New
a Class Energy Efficiency Air Cooled Scroll Compre
Cooling System
Instant / Tankless
3pH-380V-50Hz(200V/220V/415V 50Hz/60Hz)
R22 or Another
Freestanding
Thermostatic Expansion Valve
Screw
1300kg
Shanghai China (Mainland)
Shenglin
Customized Packing
CE, ISO9001
Shanghai, China
841950009
Product Description
A CLASS ENERGY EFFICIENCY AIR COOLED SCROLL COMPRESSOR LIQUID CHILLER
What is a chiller? How chillers work?
A chiller is a machine that removes heat from a liquid via a vapor-compression or absorption refrigeration cycle. This liquid can then be circulated through a heat exchanger to cool air or equipment as required. As a necessary byproduct, refrigeration creates waste heat that must be exhausted to ambient or, for greater efficiency, recovered for heating purposes. Concerns in design and selection of chillers include performance, efficiency, maintenance, and product life cycle environmental impact.

These systems have these important elements:
Compressor :Provides the energy system.
Condenser :Rejects heat gained by the gas using ambient air or cooling tower water to condense the gas back to a liquid for use again by the evaporator. The condenser is a heat exchanger, which dissipates the heat absorbed in the evaporator.
System Expansion :The liquid refrigerant enters the expansion device which reduces pressure. By reducing its pressure abruptly decreases its temperature.
Evaporator :Cools the water, water/glycol or air by transferring the heat to the refrigerant which is turned into a gas. Compressor - takes this gas and increases its pressure so that ambient air or water can remove the heat. The coolant at low temperature and pressure through the evaporator, which like the condenser is a heat exchanger and absorbs heat.
Holding Tank :holds the circulating coolant, usually water (can be water/glycol), tank is sized large enough to prevent turbulent flow in tank causing pump cavitation.
Pump :Circulates coolant from the holding tank to the evaporator and from the evaporator to the machine or process being cooled and back to the tank.
Control Panel :Houses temperature controller, compressor contactor, pump starter, 3-phase fuses, control transformer, safety controls, run and fail lights.
In SHENGLIN, we have the best solutions and advice to assess what type of chiller you need because we have equipment type air-cooled, water cooled, screw, scroll from 1 to 3000 tons.


Contact person:
Iris Qian
Tei: 0086 21 35324169 ext 204
What is a chiller? How chillers work?
A chiller is a machine that removes heat from a liquid via a vapor-compression or absorption refrigeration cycle. This liquid can then be circulated through a heat exchanger to cool air or equipment as required. As a necessary byproduct, refrigeration creates waste heat that must be exhausted to ambient or, for greater efficiency, recovered for heating purposes. Concerns in design and selection of chillers include performance, efficiency, maintenance, and product life cycle environmental impact.

These systems have these important elements:
Compressor :Provides the energy system.
Condenser :Rejects heat gained by the gas using ambient air or cooling tower water to condense the gas back to a liquid for use again by the evaporator. The condenser is a heat exchanger, which dissipates the heat absorbed in the evaporator.
System Expansion :The liquid refrigerant enters the expansion device which reduces pressure. By reducing its pressure abruptly decreases its temperature.
Evaporator :Cools the water, water/glycol or air by transferring the heat to the refrigerant which is turned into a gas. Compressor - takes this gas and increases its pressure so that ambient air or water can remove the heat. The coolant at low temperature and pressure through the evaporator, which like the condenser is a heat exchanger and absorbs heat.
Holding Tank :holds the circulating coolant, usually water (can be water/glycol), tank is sized large enough to prevent turbulent flow in tank causing pump cavitation.
Pump :Circulates coolant from the holding tank to the evaporator and from the evaporator to the machine or process being cooled and back to the tank.
Control Panel :Houses temperature controller, compressor contactor, pump starter, 3-phase fuses, control transformer, safety controls, run and fail lights.
In SHENGLIN, we have the best solutions and advice to assess what type of chiller you need because we have equipment type air-cooled, water cooled, screw, scroll from 1 to 3000 tons.
Item | Model | TPAS-040ASH | TPAS-050ASH | TPAS-060ASH | TPAS-075ASH | TPAS-085ASH | TPAS-100ASH | TPAS-120ASH | |
Nominal cooling capacity | kcal/h | 90128 | 114724 | 130290 | 178020 | 214140 | 249400 | 291540 | |
kw | 104.8 | 133.4 | 151.5 | 207 | 249 | 290 | 339 | ||
Total input power | kw | 39.7 | 49.7 | 56.3 | 75.3 | 88.3 | 103.4 | 118.2 | |
Max.Running current | A | 86 | 108 | 128 | 162 | 180 | 216 | 246 | |
Power | 3PH-380V-50HZ(200V/220V/415V 50HZ/60HZ) | ||||||||
Refrigerant | Type | R22 | |||||||
Refrigerant charge | kg | 28 | 35 | 43 | 53 | 60 | 72 | 86 | |
Control method | thermostatic expansion valve | ||||||||
Compressor | Type | Semi-hermetic screw | |||||||
Power | kw | 37.3 | 46.1 | 51.9 | 69.9 | 81.7 | 96.2 | 109.4 | |
Start-up mode | Y | ||||||||
Capacity control | % | 0-25-50-75-100 | |||||||
Evaporator | Type | Shell and Tube | |||||||
Chilled fluid flow | m3/h | 18.0 | 22.9 | 26.0 | 35.5 | 42.7 | 49.7 | 58.1 | |
Inlet/outlet pipe diameter | Inch | 3" | 3" | 3" | 3" | 4" | 4" | 4" | |
Condenser | Type | Air cooled high-efficient inner threaded copper-tubing aluminum fin type | |||||||
Fan | Type | Low noise outer rotor fan | |||||||
Power | kw | 2.4 | 3.6 | 4.4 | 5.4 | 6.6 | 7.2 | 8.8 | |
Chilled fluid flow | m3/h | 40000 | 48000 | 55000 | 71000 | 82000 | 95000 | 115000 | |
Safety protectio | Compressor over temperature,over current,high and low pressure,over temperature,flow switch, phase sequence,phase-missing,exhaust Overheating,antifreezing. | ||||||||
Dimension | Length | mm | 2000 | 2200 | 2500 | 3200 | 3500 | 4000 | 4800 |
Width | mm | 1500 | 1700 | 1850 | 1950 | 1950 | 1950 | 1950 | |
Height | mm | 2000 | 2000 | 2150 | 2200 | 2200 | 2200 | 2200 | |
Net weight | kg | 1300 | 1620 | 1930 | 2260 | 2420 | 2860 | 3250 | |
Running weight | kg | 1390 | 1870 | 2210 | 2420 | 2680 | 3020 | 3460 |


Contact person:
Iris Qian
Tei: 0086 21 35324169 ext 204