Environmental Climate Temperature Shock Chamber with Cold and Heat Two Chambers Structure

Price $102000.00 Compare
Min Order 1 Set
Shipping From Shanghai, China
Popularity 244 people viewed
Quantity
+-
 

Shanghai Atec Laboratory Equipment Co., Ltd.

VIP   Audited Supplier 3 years
Profile Certified by SGS/BV
JTSM-B/S/E Series
After-Sales Service Available
380V±10%/50Hz±1(3p+N+G)
CE
1 Year
+50ºC~+150ºC
± 0.5 ºC
± 2 ºC
2 ºC
Jupiter
Wood Case
50L / 100L /150L / 200L / Customized
China
8514199000
Product Description
Temperature Shock Chamber with Two Chambers
Product Description

Introduction
Such a series of impact test chamber adopts a structure of cold and thermal chambers and utilizes a bucket rapidly transforming specimens to the test area, so as to conduct cold and thermal shock tests.

This impact mode reduces thermal load during cold and thermal impact and shortens temperature recovery time to the greatest extent.

Feature

  • This series chamber using cold and heat two chambers structure, mainly used for hot and cold temperature impact test material in an instant, in a very short period of time test caused by heat bilges cold shrink can bear by chemical or physical damage.
  • 7 inches large color touch screen program control, running status be clear at a glance.
  • The user can save 50 to edit test procedure, also has a record of 365 days parameter function (equipped with paperless recorder).
  • In accordance with the requirements of recovery time, automatic equipment precooling, preheating temperature, adjust the working status of test cases to be the best.
  • Low error, the wind speed is high, the uniform sample exposure.
  • Province energy consumption, low noise design.
  • Shopping basket conversion time is less than 10 seconds, temperature recovery time for 5 minutes.
  • High temperature and low temperature zone can be independently controlled respectively, three with a chamber.
  • GJB150.3, GJB150.4, GJB150.5 ...
Product Parameters
Parameters for all models 
Temperature Shock Chamber(Two Chamber)
ModelJTS50M-B/S/ETS100M-B/S/EJTS150M-B/S/EJTS200M-B/S/EJTS320M-B/S/EJTS500M-B/S/EJTS1000M-B/S/E
Nominal inside volume(L)50L100L150L200L320L500L1000L
Performance ParameterHeating chamberTemperature exposure range+50ºC~+150ºC
Upper limit of preheating temperature200ºC
Heating timeRT~+200ºC, B type: ≤ 50min; S type: ≤ 40min; E type: ≤ 30min
Cooling chamberTemperature exposure rangeB type: 0~-40ºC; S type: 0~-55ºC; E type: 0~-65ºC
Lower limit of pre cooling temperature-75ºC
Cooling timeRT~+70ºC, B type: ≤ 60min; S type: ≤ 50min; E type: ≤ 40min
Hand basketTemperature shock rangeB type:-40ºC~+150ºC; S type: -55ºC~+150ºC; E type: -65ºC~+150ºC
Temperature fluctuation≤±0.5
Temperature uniformity≤2ºC
Temperature deviation≤±2ºC
Conversion time≤10s
Temperature recovery time5 min
Load (steel)3kg5kg7kg10kg15kg20kg40kg
Optional: High and low temperature test functionTemperature range-65ºC~+150ºC
Temperature rise and fall rateB type nearly 2ºC/min; S type nearly 4ºC/min; E nearly 6ºC/min
RemarksAbove indicators are measured in no load at ambient temperature of 20±2°C(According to GB/T 5170.2-2017)
Inner dimensionsD3504005006006508001200
W350500600600600700800
H4005005005505509001000
External dimensionsD2000225023502550195022002650
W1400157016701670270030003000
H1950215021502250230024002600
Caster4, 6 for over 500L (caster dimension is not included in above overall dimension,caster rises by 60-120mm)
Test holeOneΦ50OneΦ100
Stainless steel shelf (2 pcs in standard configuration)Bearing 15kg/pcBearing 30kg/pcBearing 50kg/pc
Using environment temperature0~+40ºC
ShellSprayed steel plate
InteriorSUS304 stainless steel
Cooling modewater-cooling, (water temperature 7~28ºC, hydraulic pressure 0.2~0.4Mpa,To ensure cooling performance)
Controller7′ Color touch screen Controller
Communication functionRS485 or standard RJ45 network interface, standard USB interface
Power supply380V+10%/50HZ+1,three-phase-five-wire system (3P+N+G)
Meet the testing methodGJB150.5-2009, GB/T 2423-2008;
The optional high and low temperature test function also meets the requirements of GB2423.1-2008, GB2423.2-2008, GJB150.3-2009, GJB150.4-2009.
Safety precautionsPower supply undervoltage, overvoltage, phase loss, and phase sequence error protection; Triple over temperature protection; Heater short circuit protection, refrigeration unit overpressure/ overload/ oil shortage protection; humidifier fault protection; Overload/overheating protection for blower motor, overcurrent protection and leakage protection for control board; Cooling water shortage protection, gas source undervoltage protection, etc.
Optional1.Optional high and low temperature testing function; 2. Optional special test holes and special shelves; 3. Optional liquid nitrogen function.
Centralized Control

 
Our Services

Pre-sales Service
We can provide samples to help our customers evaluate our products. Our professional sales team offers comprehensive pre-sales support, including detailed product information and tailored solutions to meet customer requirements.

After-sales Service
We offer a one year warranty for our products, during which we provide free spare parts and video guidance for installation and maintenance. Our team is available to assist with any issues that arise. If the product is damaged due to manufacturing defects, we will provide free repair or replacement. However, if the damage is caused by improper handling by the customer, the associated costs must be covered by the customer.

Customization Service
We support customization, including functionality, structure, style, and color, to meet the specific requirements of different customers. For detailed information, please feel free to contact us.

Partnership Opportunities
We welcome collaboration with local agents and distributors to expand our market reach and support mutual growth.

Certifications

Company Profile

Other Products

Cooperation Cases

Packaging & Shipping
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA