ETCR-5000 3 Phase Power Quality Analyzer Power Quality Data Logger
Introduction:
ETCR-5000 3 Phase Power Quality Analyzer Power Quality Data Logger is specially designed for comprehensive analysis and diagnosis on all the voltage, current, power, harmonic, and phase electric parameters.
It applies to the electricity industry, petrochemical, metallurgy, railway, mining enterprises, scientific research institutions, and metrological departments.
ETCR-5000 3 Phase Power Quality Analyzer Power Quality Data Logger is suitable for field tests of three phases, and it is multi-functional and intelligent, with a concise man-machine operation.
Parameters:
Functions:
Waveform real-time display (4 channels voltage/4 channels current).
True RMS values of voltages and currents.
The DC components of voltages.
Peak current and voltage values.
Minimum and maximum half-cycle RMS current and voltage values.
Phasor diagram display.
Measurement of each harmonic up to order 50.
Bar charts show harmonic ratios of the current and voltage of each phase.
Total harmonic distortion (THD).
Active, reactive, apparent power, by phase, and cumulative.
Active, reactive, apparent energy, by phase, and cumulative.
Transformer K factor.
Power factors (PF) and displacement factors (DPF or COSΦ).
Short-term voltage flicker (PST).
Three phase unbalance(current and voltage).
3 Phase Power Quality Analyzer Power Quality Data Logger:






Introduction:
ETCR-5000 3 Phase Power Quality Analyzer Power Quality Data Logger is specially designed for comprehensive analysis and diagnosis on all the voltage, current, power, harmonic, and phase electric parameters.
It applies to the electricity industry, petrochemical, metallurgy, railway, mining enterprises, scientific research institutions, and metrological departments.
ETCR-5000 3 Phase Power Quality Analyzer Power Quality Data Logger is suitable for field tests of three phases, and it is multi-functional and intelligent, with a concise man-machine operation.
Parameters:
Influence factor | Test item | Base condition | Working condition |
Environment temperature | All parameters | (23±2)°C | -10°C~ 40°C |
Relative humidity | All parameters | 40%~ 60% | <80% |
Phase-to-neutral voltage | All parameters | (100±1%)V | 1.0V~ 1000V |
Phase-to-phase voltage | True RMS phase-to-phase voltage | (200±1%)V | 1.0V~ 2000V |
Current | True RMS current | (5±1%)A | 10mA~ 1000A |
Network frequency | All parameters | 50Hz±0.1Hz | 40Hz~ 70Hz |
Phase shift | Active power and active energy | Cosφ=1 | Cosφ: 0.2~ 1.0 |
Reactive power and reactive energy | Sinφ=1 | Sinφ: 0.2~ 1.0 | |
Harmonic | All parameters | <0.1% | 0.0%~ 100% |
Voltage unbalance | All parameters | <10% | 0.0%~ 100% |
Working voltage of device | All parameters | DC9.8V±0.1V | DC9.5V~ 10.5V |
External electric field, magnetic field | All parameters | Should be avoided | |
Test position | Measured related parameters of current | Tested wire at the center of clamp. |
Power supply | Rechargeable lithium-ion battery pack 9.6V, backup charger. |
Battery indicator | The battery symbol shows dumped energy. When the voltage is too low, automatic shutdown after 1 minute. |
Power consumption | The current consumption of a normal test is 490 mA, continuous working for 8 hours. |
Display mode | LCD color screen, 640dots×480dots, 5.6 inches, display domain: 116mm×88mm. |
Size of clamp | 008 small sharp current clamp: 7.5mm×13mm; 040 circle current clamp: 35mm×40mm; 068 circle current clamp: 68mm×68mm; |
Instrument dimensions | L×W×H: 240mm×170mm×68 mm. |
Number of channels | 4U/4I. |
Phase-to phase voltage | 1.0V~2000V. |
Phase-to-neutral voltage | 1.0V~1000V. |
Current | 008 current clamp: 10mA~10.0A; 040 current clamp: 0.10A~100A; 068 current clamp: 1.0A~1000A; Optional current transformer: instrument input current 1mA~500mA. |
Frequency | 40Hz~70Hz. |
Parameters of electricity | W, VA, Var, PF, DPF, cosφ, tanφ. |
Energy parameters | Wh, Varh, Vah. |
Harmonic | Order 0~50. |
Total harmonic distortion | Order 0~50, each phase. |
Expert mode | Yes. |
Number of Transient records | 150 sets. |
Voltage flicker | Yes. |
Starting current mode | Yes, 100 seconds. |
3 phases unbalance | Yes. |
Record | 300 days(simultaneous recording 20 parameters, record one point every 5 seconds). |
Min/Max recorded value | Measurement of maximum and minimum values over a period of time. |
Alarm | 40 different types of parameter selections, 12,800 sets alarm logs. |
Peak | Yes. |
Phasor diagram display | Automatically. |
Capacity of Snapshots | 60. |
Menu language | English/Chinese. |
Communication | USB. |
Automatic switching off | When an alarm campaign is initiated or a search for transients, an inrush current capture, or a trend recording is pending or in progress, the device does not automatically switch off. |
In another test mode, 15 minutes without keystrokes and automatic shutdown after prompt 1 minute. | |
Backlight function | Yes, suitable for use at night and in dark places. |
Weight | Host: 1.6kg (with battery). |
008 small sharp current clamp: 170g×4; | |
040 circle current clamp: 190g×4; | |
068 circle current clamp: 510g×4; | |
Test wires and power adapter: 900g; | |
Total weight: about 10.5kg (with packaging). | |
Length of voltage test wire | 3m. |
Length of current sensor wire | 2m. |
Working temperature and humidity | -10°C~40°C; below 80%Rh. |
Storage environment | -10°C~60°C; below 70%Rh. |
Input impedance | Input impedance of test voltage: 1MΩ. |
Withstand voltage | Withstand 3700V/50Hz sinusoidal AC voltage for 1 minute between instrument wiring and shell. |
Insulation | Between instrument wiring and shell ≥10MΩ. |
Structure | Double insulation, with insulation vibration-proof sheath. |
Safely rules | IEC 61010 1000V Cat III / 600V CAT IV, IEC61010-031, IEC61326, Pollution degree: 2. |
Packing Size | 400*270*270(mm) (L*W*H) |
Weight | 8Kg |
Functions:
Waveform real-time display (4 channels voltage/4 channels current).
True RMS values of voltages and currents.
The DC components of voltages.
Peak current and voltage values.
Minimum and maximum half-cycle RMS current and voltage values.
Phasor diagram display.
Measurement of each harmonic up to order 50.
Bar charts show harmonic ratios of the current and voltage of each phase.
Total harmonic distortion (THD).
Active, reactive, apparent power, by phase, and cumulative.
Active, reactive, apparent energy, by phase, and cumulative.
Transformer K factor.
Power factors (PF) and displacement factors (DPF or COSΦ).
Short-term voltage flicker (PST).
Three phase unbalance(current and voltage).
3 Phase Power Quality Analyzer Power Quality Data Logger: