EVD-145mm
Cooling Tower
ISO, CE
New
Mixing Ventilation
Wet
Open
Square
Low
PVC
Cooling Tower
145mm
25 mm
One Year
Cooling Tower
Replace for Cooling Tower
NEWIN
Wood Packing
customized
China
84195000
Product Description
EVD Drift Eliminator For Cooling Tower

Newin EVD celluar drift eliminator removes small droplets of water that are entrained in the exhaust air to minimize the nuisance and health issues that they create if allowed to escape through the top of the tower along with the heated air. EVD series drift eliminators are designed to create a tortuous path for the air stream. When the water droplets move through them, they are forced to change direction and impact the drift eliminator side walls, coalescing and draining back into the wet section of the cooling tower.
FEATURES
-Anti-aging, high water absorption.
-low airflow resistance, high strength.
-easy installation and long service life.
-can be the replacement of air inlet louver.
PROPERTIES
With different request in EVD drift eliminators, like length and width, materials or thickness, etc, please inform us your detailed request to get correct solution and offer. Newin could cover all customer requirements. Fill media in flame retardant or anti-bacterial execution are also available on request.
Packing and Loading: LCL shipment: by plywood pallet/case/carton, FCL shipment: by container
Trade Terms: EXW, FOB, CFR,CIF, DDU.
Payment term: T/T, L/C, West Union
Minimum Order Quantity: 1000pcs
EVD drift eliminator Pictures --- cooling tower drift eliminator


You may be also interested in some related parts, for your reference.

Contact person
May zhou

Newin EVD celluar drift eliminator removes small droplets of water that are entrained in the exhaust air to minimize the nuisance and health issues that they create if allowed to escape through the top of the tower along with the heated air. EVD series drift eliminators are designed to create a tortuous path for the air stream. When the water droplets move through them, they are forced to change direction and impact the drift eliminator side walls, coalescing and draining back into the wet section of the cooling tower.
FEATURES
-Anti-aging, high water absorption.
-low airflow resistance, high strength.
-easy installation and long service life.
-can be the replacement of air inlet louver.
PROPERTIES
With different request in EVD drift eliminators, like length and width, materials or thickness, etc, please inform us your detailed request to get correct solution and offer. Newin could cover all customer requirements. Fill media in flame retardant or anti-bacterial execution are also available on request.
Module Length (Max) | mm | 2440 |
Module Width | mm | 500 |
Module Depth | mm | 145 |
Flute Height | mm | 25 |
Flute Corrugation Angle | degrees | - |
Surface Area | m2/m3 | 125/142 |
Sheet Thickness - Before Forming | mm | 0.45 |
Sheet Thickness - After Forming | mm | 0.40 |
Max. application temp. (short time) - PVC | °C | 60 |
Max.operating temp. (short time) - High temp. | °C | 80 |
Customized size and thickness available for special request. Contact Newin for details! |
Trade Terms: EXW, FOB, CFR,CIF, DDU.
Payment term: T/T, L/C, West Union
Minimum Order Quantity: 1000pcs
EVD drift eliminator Pictures --- cooling tower drift eliminator


You may be also interested in some related parts, for your reference.

Contact person
May zhou