Product Description
Specifications
Input type: NTC10K (B=3380)
Refrigeration meter
Temperature range: -50~150c
External dimension (mm): 76x34x72
Hole size: 70x28mm

The meter has international standard External dimension and 3-key gentle push-switch setting, single row, 3-LED display, temperature error can correct, the meter has heating or cooling function,
you can choice freely. It adopts ON/OFF adjustment, return difference can be adjusted,control
precision is high.
Technical specification
1,Input type:NTC10K (B=3380)
2,Temperature display range: -50~150ºC
3,Relay output contact capacity:7A 240VAC
4,External dimension(mm):76×34×72 hole size(mm):70×28
5,Working power:AC110~242V,50/60HZ, power dissipation is less than 3W
6,Working environment:temperature 0~50.0ºC, relative humidity≤85%RH, without corrode and strong electric radiation.
The inner parameters
Input type: NTC10K (B=3380)
Refrigeration meter
Temperature range: -50~150c
External dimension (mm): 76x34x72
Hole size: 70x28mm

The meter has international standard External dimension and 3-key gentle push-switch setting, single row, 3-LED display, temperature error can correct, the meter has heating or cooling function,
you can choice freely. It adopts ON/OFF adjustment, return difference can be adjusted,control
precision is high.
Technical specification
1,Input type:NTC10K (B=3380)
2,Temperature display range: -50~150ºC
3,Relay output contact capacity:7A 240VAC
4,External dimension(mm):76×34×72 hole size(mm):70×28
5,Working power:AC110~242V,50/60HZ, power dissipation is less than 3W
6,Working environment:temperature 0~50.0ºC, relative humidity≤85%RH, without corrode and strong electric radiation.
The inner parameters
Series | Prompt | Name | Setting range | Remark | Ex- Factory | |
- | 0 | SP | Temperature set value | - | Press orkey 3 second can revised the set value, the setting range be determined by SPL and SPH . | 50 |
The second menu | 1 | Loc | Electronic lock | 0~50 | When Loc =18, all parameters can be revised; When Loc ≠18, all parameters can not be revised. | 18 |
2 | Hy | Control return difference | 1~20 | 1 | ||
3 | SC | Measurement error modifier | -20~20 | The measured value can be modified through increasing or decreasing this data. | 0 | |
4 | SPL | Range lower limit | The starting point to | SPH≥SPL , The setting range: -50~150ºC | -50 | |
5 | SPH | Range upper limit | to full range | 150 | ||
6 | COL | System function choice | - | H_t: Reverse control (heating ); C_t: Positive control(cooling ). | H_t | |
7 | T | Delay time | 0~60 minutes | When refrigeration control, it is effective; it is 0, turn off delay feature | 2 |