Factory Direct Supply Cheap Price Long Life Solar Cross Flow Fan Heater for Electrical Appliance
Model:PC40B24160C
Low noise with high air flow rates and low back pressures, compact slim design with anti-vibration rubber mechanical soft connection system, moisture proof and water proof versions are available for entire range tangential blowers with integrated and intelligence EC technology motor with PWM signal and 0~10V analog voltage to adjust power, and ErP2015 (Energy-related Products) directive conformity.

Impeller Sizes: from 30mm to 80mm diameter;
Sound Level: from 32dBA to maximum 48dBA according different rotation speed;
Airflow: maximum to 600CMH, Cubic Meter per Hour, equal to approx. 353CFM , Cubic Feet per Minute;
Air Pressure: Maxim to 80Pa, equal to 8.16mm H2O and to 0.32 inches H2O;
Power: Maximum motor input power goes to 100W motor diameter 80mm.
General Characters:
1-1 | Rated Voltage | 24 VDC |
1-2 | Operating Voltage | 16 ~ 28 VDC |
1-3 | Rated Speed | 2600 RPM |
1-4 | Input Current | 0.11 A |
1-5 | Input Power | 2.64 W |
1-6 | Acoustical Noise | 33 dB(A) |
1-7 | Life Expectance | 50,000Hours(L10) At 40ºC room, humidity 15%~65%RH. |
1-8 | Direction of Rotation | Clockwise seen on motor |
1-9 | Insulation Class | Class B |
1-10 | Insulation Resistance | 50 Mega Ohm minimum at 500VDC Between frame and (+) terminal |
1-11 | Motor Protection | Locked rotor protection Polarity protection Automatic restart capability |
1-12 | Speed Control | Control input 0~10VDC |
1-13 | Dielectric Strength | 5mA maximum at 500VAC 50Hz five second Between frame and (+) terminal |
1-14 | Air Flow | 38.25 CFM / 65 m3/H |
1-15 | Static Pressure | 2.04 mmH2O / 20 Pa |
1-16 | Protection Type | IP44 |
Environmental Characters:
2-1 | Dimension | 61 x 63 x 229 (see dimension drawing) |
2-2 | Material of Impeller | Aluminum alloy |
2-3 | Number of Blades | 22 |
2-4 | Bearing System | NMB ball bearing |
2-5 | Mounting Position | Any |
2-6 | Lead Wire | Red , Black, White AWG22# |
2-7 | Package | Standard |
Electrical Protection
3-1 | Locked-rotor Protection | Over-current limiting circuit protects motor from damage at least for 72 hours of locked rotor condition at rated voltage. |
3-2 | Reverse Polarity Protection | No damage if the positive and negative leads are reversed under maximum operation voltage conditions. |
3-3 | Over Voltage Protection | The circuit will be shut down automatically when input voltage over 15VDC. And re-started when Voltage down to 15VDC below. |
3-4 | Soft Start | In 5 seconds after power on and speed control voltage gets to 1.5V. |
3-5 | RoHS | All the material meets RoHS standard. |
Environmental Characters
4-1 | Operating Temperature | -25ºC to 60ºC |
4-2 | Storage Temperature | -40ºC to 75ºC |
4-3 | Operating Humidity | 5% to 90% RH |
4-4 | Storage Humidity | 5% to 95% RH |
4-5 | RoHS | All the material meets RoHS standard. |
Performance Curve:
Testing Condition
Input Voltage----Operating voltage (24 VDC)
Temperature-----Room temperature
Humidity---------65%RH
Test distance-----1m
Outline Drawing
Note
1. Connection line 3X (Red, Black, White AWG22#);
Red=+24VDC, White=0-10VDC, Blue=GND.
Safety Requirements
- Make sure that the metal casing of the stator connected to the ground before being powered on.
- If the fan doesn't work after been powered on, please check the speed control input voltage, it may not be well connected. To prevent the suddenly start of the fan to hurt hands or other personal injury; do not touch the impellers or rotor when the power is on.
- Fan needs a few seconds to start after being powered on. To prevent personal injury, do not touch the impellers or rotor when the power is on or in a low speed.
- Unless they are instructed by the person(s) responsible for their safety, those who are lack of physical, mental or sensory capacities and proper practical experience or expertise cannot use this appliance. Please do not let the children play with this product.
- If the power cord be damaged, the power cord must be replaced by the manufacturer in order to avoid accident of the proxy service personnel or the equivalent qualification maintenance personnel.
- As an integral part of the fan, this DC motor cannot be used alone without impeller or load.
- Please carefully read this technical specification before using the product.
Products of the same series
Model Part No. | Rated Voltage VDC | Air Flow M3/H | Air Pressure Pa | Rated Speed RPM | Sound Level dB(A) | Total Length mm |
PC40B1298C | 12 | 30 | 15 | 2600 | 30 | 145 |
PC40B2498C | 24 | 30 | 15 | 2600 | 30 | 145 |
PC40B12160C | 12 | 65 | 20 | 2600 | 33 | 207 |
PC40B24160C | 24 | 65 | 20 | 2600 | 33 | 207 |
PC40B12198C | 12 | 92 | 25 | 2600 | 34 | 245 |
PC40B24198C | 24 | 92 | 25 | 2600 | 34 | 245 |
PC40B12250C | 12 | 116 | 27 | 2600 | 35 | 295 |
PC40B24250C | 24 | 116 | 27 | 2600 | 35 | 295 |
PC40B12300C | 12 | 138 | 29 | 2600 | 36 | 347 |
PC40B24300C | 24 | 138 | 29 | 2600 | 36 | 347 |
PC40B12348C | 12 | 162 | 32 | 2600 | 37 | 399 |
PC40B24348C | 24 | 162 | 32 | 2600 | 37 | 399 |
PC40B12420C | 12 | 195 | 34 | 2600 | 38 | 467 |
PC40B24420C | 24 | 195 | 34 | 2600 | 38 | 467 |
Q:How about the delivery time ?
A:Within 25 days after we receive the order.
A:T/T & L/C, other types please contact us.
A: Generally speaking, the MOQ is 100 pieces. Different products have different MOQ. Please contact us.
A: All available shipping ways could be applied, by courier, air or sea. Appointed shipping company or our own forwarders all could be used in shipment Full-way tracking the cargos for you before the goods arrive.