Factory Price 12V Regulated 60W DC12V 5AMP SMPS Power Supply

Price $4.60 Compare
Min Order 100 Pieces
Shipping From Guangdong, China
Popularity 478 people viewed
Quantity
+-
 

Shenzhen Mingwei Electric Power Co., Ltd.

VIP   Audited Supplier 8 years
Profile Certified by SGS/BV
S-60-12
Single
2 Years
51 - 100W
110-220V
Series Switching Power Supply
Self-excited Switching Power Supply
Frequency Modulation Type
Terminal Power Distribution Equipment
Two-way Transmission
PWM
CE, RoHS, ISO, CCC, CB
Mwish
MWISH
Export Package
159*98*38 30PCS/CTN
China
8504401990
Product Description
*Low price and high reliablity
*105ºC Ootput capacitor
*AC input power suitable for the world
*High efficiency and low operation tenperature
*Sofft-start current can reduce the AC input impact effecticly
*With short-circuit and overload protection
*Compact size,light weight
*100%full-load bum-in test
*Installed with EMI filter, mlnlmum wave
Specification                            ModelNo.    S-60-5    S-60-12   S-60-15   S-60-24
DC output voltage5V   12V15V24V
Output voltage range (Note:2)     ±2%     ±1%     ±1%     ±1%
Rated output current12A5A4A2.5A
 output  current range   0~12A0~5A0~4A0~2.5A
Wave and noise (Note:3)75mVp-p 60mVp-p60mVp-p   50mVp-p
Inlet stability (Note:4)     ±0.5%     ±0.5%      ±0.5%     ±0.5%
Load stability (Note:5)     ±1%     ±0.5%      ±0.5%     ±0.5%
DC output power60W60W60W60W
Efficiency  80%83%        84%      85%
Adjustable range for DC voltage      ±10%     ±10%     ±10%     ±10%
AC input voltage range  85-132VAC/170-264VAC  47-63Hz  240~370VDC
output current1.3A/115V 0.65A/230V
AC rush current15A/115V 36A/230V
Leakage current<0.5mA/240VAC
Overload protection          105%-150% hiccup mode,auto-recovery
Over-Voltage protection     115%-135% rated output voltage
High-temperature protection -10ºC~+60ºC,20%~90%RH
Temperaut re cofficient ±0.03%/ºC(0~50ºC)
Setup,rise,hold up time 200ms,100ms,30ms
Vibration 10~500Hz, 2G 10min,1 cycle Pariod for 60min, Each axes
Withstand voltage   I/P-O/P:3Kv    I/P-FG:1.5KV   O/P-FG:0.5KV   1minute
Insulation resistance  I/P-O/P   IP/FG   OP-FG:500VDC/100MΩ 
Working temperature and humidity -10ºC~+60ºC,20%~90%RH
Overall dimension 159*98*38 mm
Safety StandardsMeeUL 1012 requirement
EMC Standards Design refer to GB9254,EN55022 ClassA
Weight0.5Kgs
Note:
1.The testina condition for The Paramenter is:230VAC input,rated load, 25ºC 70% RH Temperature
2.Error incude the seting error, line stability and load stability
3.Wave test:adopt in "A12"double wire for 20MHz,and 0.1 UF capacitor short-circuit for interrupt bug 
4.Inlet voItage stability test:When is over load,the lowest voItage of inlet is up to the hiqhest voltaqe
5.Load stability test:the load is from 0% to 100%
6.C3,4 must be knocked down