AMC16-DETT
2years
Digital
Indirect Connected
Meter for Industry and Home Use, Reactive Energy Meter, Base Station Energy Meter
Single-phase
Electronic Meter
Terminal
Pulse Peak
Energy Meter
RoHS, ISO, CE
Non-Customized
Base Station Power Meter
OEM ODM
1 Channel: -48VDC
Power Supply Output:+12V/100mA, -12V/50mA
-40V~-60VDC
IP20
ACREL
Fob Shanghai
89.7*87.8*52mm
China
9028301300
Product Description

Product Description
AMC16-DETT Base Station DC Energy Meter
General

Base station dedicated DC energy meter AMC16-DETT is specially designed for base stations where have sharing requirements, and switch power supply is without the function of sub-user metering. The meter could measure 6 circuits DC energy, and supply working current to the matched hall sensors. Meanwhile, it can realize zero drift calibration by upper computer software. have the functions of telemetering,teleindication,teleadjusting, metering at real time, energy quality abnormal alarm, data storage and processing, data interaction. This meter can measure  DC power consumption of three operators, providing detail datas for base station.

6 Channels DC Energy Meter for Communication Base Station Tower



Features
1.DC rated voltage: 1 channel: -48VDC
2.Accuracy:1%In≤I≤10%In error±2.5%; I>10%In error±2%
3.RS485(MODBUS-RTU)
4.LED display
5.DIN 35 mm
6.Rated U and I:Total 200A/5V


Technical Parameters
Technical parameterIndex





input
DC rated voltage1 channel: -48VDC

DC current
6 channels hall sensors: total 200A/5V, China Telecom, China Mobile, China Unicom and the 1st channel reserve 50A/5V, 2nd
channel reserve 100A/5V.
Commercial power
monitoring

1 channel: 0-5VDC

Overload capacity
Voltage:1.2times continued,2 times continued 1s;
Current: 1.2 times continued,10 times continued 1s.
Accuracy (superposition hall sensors)1%In≤I≤10%In error±2.5%; I>10%In error±2%

Measurement resolution
Voltage output accuracy 0.01V;   current output accuracy 0.01A;
power output accuracy 0.01kw; energy output accuracy 0.01kwh









functions

Basic function
Monitor device system time, total voltage, output total current, power, energy, each channel voltage, current, power, energy; LED
indicator display;485 communication




Metering function
Start current: under rated voltage, when the load current value of the meter doesn't exceed 1% of the max. current, the meter starts.
Shunt running current: when there is no current in the current circuit of the meter, and 85%-125%of the rated voltage is applied on the voltage circuit, the calculator shall not have more than
one digital change


Alarm function
DC voltage output low alarm,DC voltage output high alarm,one power down alarm, module voltage loss alarm, metering branch error alarm, internal program error alarm, clock error alarm,
memory failure alarm, AC input power failure alarm

Function





Dimension
Wiring



6 Channels DC Energy Meter for Communication Base Station Tower

Quotation

 

Recommend Hall Sensor
 

6 Channels DC Energy Meter for Communication Base Station Tower

Networking

6 Channels DC Energy Meter for Communication Base Station Tower

 

6 Channels DC Energy Meter for Communication Base Station Tower






Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA