BIM-CH1
Self-Test
Temperature Monitoring
Soe Fault Record
One or Two Channel
AC/DC System
DIN Rail
Blue Jay
Carton
10*19*10
Chongqing
Product Description
The BIM-CH1 monitors the insulation resistance of DC systems (IT systems) devices up to DC 0- 1000V. BIM-CH1 has insulation monitoring start and stop functions. After insulation monitoring is turned on, the insulation resistance of the positive and negative poles to the ground can be monitored in real-time. The monitoring results are not affected by DC voltage fluctuations and the symmetry of the insulation resistance of the positive and negative poles.
BIM-CH1 is equipped with RS485 /Modbus communication to remotely monitor the system status. BIM-CH1 uses two working principles for monitoring: the unbalanced bridge method and the balanced bridge method, allowing continuous monitoring of voltage and resistance values. Optional current sensors or temperature sensors can be configured for current and temperature measurements.

BIM-CH1 is equipped with RS485 /Modbus communication to remotely monitor the system status. BIM-CH1 uses two working principles for monitoring: the unbalanced bridge method and the balanced bridge method, allowing continuous monitoring of voltage and resistance values. Optional current sensors or temperature sensors can be configured for current and temperature measurements.



- Adaptive capacitance to ground;
- Widely insulation monitoring range (100V~1000VDC);
- Monitoring the insulation resistance for unearthed DC systems: 1KΩ~10MΩ;
- Measured value indication via a multi-functional LCD;
- Automatic device self-test with disconnection monitoring;
- DC voltage reverse connection alarm function;
- RS485 communication, MODBUS RTU protocol;
- Selectable N/C or N/O relay operation;
- Password protection to prevent unauthorized parameter changes;
- Optional temperature sensor for system temperature measurement.
Parameter | Value | |||
Power supply | 10-30VDC, Power 3w | |||
DC voltage range | 100V~1000V | |||
DC voltage measurement accuracy | ≤2V+0.3% | |||
Insulation resistance measurement range | 1KΩ~10MΩ (DC System voltage:100V~1000V) | |||
Insulation monitoring accuracy ((When :DC voltage:100V-1000V) | CY range | Resistance range | Accuracy | |
0~0.8μF | ≤60kΩ | ≤3kΩ | ||
60kΩ<R≤1MΩ | ≤5% | |||
0.8μF ~3μF | ≤60kΩ | ≤6kΩ | ||
60kΩ<R≤1MΩ | ≤20% | |||
Insulation resistance value update time after turning on | After insulation monitoring is turned on, the time until the effective resistance value can be read for the first time | 0.7s~2s | ||
Insulation resistance value update time | Switch the insulation resistance until the module can read the switched insulation resistance value. | 0.5s~3s | ||
Insulation monitoring function switching times | 50*105 times | |||
Off-line pressure test | <2mA | |||
Standard | IEC 61557-8:2018 | |||
Humidity | 85% | |||
Storage temperature | - 40°C ~125°C | |||
Operating temperature | - 40°C ~75°C |
- DC charging systems;
- DC system up to 1000 V;
- AC Systems
- Railway vehicle, electric vehicle (EV/HEV);
- Photovoltaic solar systems, energy storage systems;
- Substation DC panels, UPS power supply system;
- Medical fields and others;