Factory Price Diesel Genset Cummins/Perkins/Mtu/Mitsubishi/Sme 2000kw 2250kVA 2500kVA 2750kVA 3000kVA 3750kVA 3000kw Standby Electric Power Generator

Price $200000.00 Compare
Min Order 1 SET
Shipping From Fujian, China
Popularity 319 people viewed
Quantity
+-
 

Mecca Power Co., Limited

VIP   Audited Supplier 7 years
Profile Certified by SGS/BV
MC
Responsible
12 Months/1000 Hours Maintenance
Self-Starting Diesel Generator
Fixed
Four Stroke
Water Cooling
AC Three Phase
Low Speed
Land Use
Common Units, Standby Unit, Emergency Crew
Automation Type
Static Exciter
Mitsubishi/Sme/Mtu/Baudouin, Optional
Stamford/Leroy Somer/Marathon/Mecca, Optional
Deepsea/Comap/Deif/Smartgen, Optional
50Hz/60Hz, 1500rpm 1800rpm
230/400V, 220-480V
3.3kv-13.8kv Generator
Silent Sound Proof/Containerized/Open
Prime Power/Standby Power/Continues Operation
Tool Kit, General Introduction Manual
Mech./Elec.
Global Service
CE, ISO, OEM Authorization etc.
Data Center/Building/Power Plant/Construction
Diesel Generator Sets
Mtu 2500kVA Generator
Mecca
Both Standard Marine Packing or Compact Packing.
As below Spec. with details
China
85021
Product Description
Mecca Power, as part of a Global Power Supplier initiative, provides a professional solution for the design, application and after-sales support of generators.

Strongly focused on innovation and the inherent flexibility of product design, Mecca Power has been successful in global markets with a broad and diverse range of genset power products that can operate autonomously or independently. parallel, on-site or remotely controlled.

With more than 10 years of experience in manufacturing and exporting energy products, the Mecca team will advise you on product choices. 

Product Description

Specification
Powered by  MTU                                                                                                                              50HZ  220-440 V   500-3300KVA 
ModelLTPPRPEngineFuel Cons.Cyl.Disp.Gov.
KVA / KW KVA/KW ModelOriginL/H(100%)L
MC500M500400 450360 10V1600G10FDE101.310V17.5ADEC
MC550M550440 500400 10V1600G20FDE110.910V17.5ADEC
MC660M660528 600480 12V1600G10FDE131.712V21ADEC
MC725M725580 660528 12V1600G20FDE144.912V21ADEC
MC880M880704 800640 12V2000G65CN184.012V23.9ADEC
MC1000M1000800 900720 16V2000G25CN210.016V31.8ADEC
MC1100M1100880 1000800 16V2000G65CN230.816V31.8ADEC
MC1250M12501000 1125900 18V2000G65CN264.516V31.8ADEC
MC1375M13751100 12501000 18V2000G26FCN261.118V35.8ADEC
MC1500M15001200 13501080 12V4000G23RDE307.612V57.2ADEC
MC1650M16501320 15001200 12V4000G23DE351.512V57.2ADEC
MC1800M18001440 16251300 12V4000G23DE351.512V57.2ADEC
MC2000M20001600 18121450 12V4000G63DE398.212V57.2ADEC
MC2250M22501800 20501640 16V4000G23DE452.116V76.3ADEC
MC2500M25002000 22501800 16V4000G63DE491.616V76.3ADEC
MC2750M27502200 25002000 20V4000G23DE561.820V95.4ADEC
MC3000M30002400 27502200 20V4000G63DE611.620V95.4ADEC
MC3300M33002640 30002400 20V4000G63LDE651.220V95.4ADEC
Powered by  MTU                                                                                                                            60HZ  220-480V  625-4000KVA 
ModelLTPPRPEngineFuel Cons.Cyl.Disp.Gov.DimentionWeight
KVA / KW KVA/KW ModelOriginL/H(100%)LL*W*H (MM)KGS
MC625M62550056345010V1600G20SDE114.110V17.5ADEC3225*1485*20703870
MC688M68855062550012V1600G10SDE135.512V21ADEC3387*1531*21404890
MC750M75060068855012V1600G20SDE145.212V21ADEC3387*1531*21403784
MC875M87570080064012V2000G45CN179.612V23.9ADEC4100*1810*21306100
MC1000M100080090072012V2000G85CN196.912V23.9ADEC4100*1810*21306900
MC1125M1125900102582016V2000G45CN219.216V31.8ADEC4495*2122*22957000
MC1250M12501000113891016V2000G85CN240.816V31.8ADEC4495*2122*22957150
MC1500M150012001375110018V2000G85CN281.118V35.8ADEC4840*1825*21658200
MC2000M200016001819145512V4000G43DE348.212V57.2ADEC6150*2150*250012500
MC2200M220017602000160012V4000G83DE405.712V57.2ADEC6350*2150*250013000
MC2500M250020002250180016V4000G43DE469.816V76.3ADEC7085*2250*250014500
MC2875M287523002625210016V4000G83DE535.516V76.3ADEC7085*2250*250015000
MC3125M312525002875230020V4000G43DE598.820V95.4ADEC7160*2555*293020500
MC3438M343827503125250020V4000G83DE651.720V95.4ADEC7160*2555*293021000
MC4000M400032003637.5291020V4000G83LDE693.920V95.4ADEC7160*2555*293021000
View more products click here...
Genset Workshop



FAQ

1.Q: What is your MOQ of this item?
A:1 Set

2.Q: What are your payment terms?
A:30% TT as deposit,70% TT before Shipment or 100% LC at sight

3.Q:What's the warranty time of diesel generators?
A:Global Warranty: 12months after delivery or 1000 running hours, whichever come first.

4.Q:Can you accept the customized products?
A:Yes, of course.We accept your specific order if you can provide us your special requirements or special samples

5.Q:What's the delivery time ?
A:20 to 35 days after receiving your payment in advance.

6.Q:Do you offer OEM service?
A: Yes

7.Q:What is the power range do you have?
A:Mecca Power assemble genset from 2 to 4000kva

8.Q:What's your special compare to other manufacturer?
A:We can delivery genset 1000units/month as engine and alternator OEM and Strategic partners. Especially for big quantity and big power projects, we support not only by solutions and tender documents, but also by fast delivery time and good price.


-----------------------------------------------------------------------------------------------MAITAINENCE---------------------------------------------------------------------------------------------

General Troubleshooting          

This section lists the generating set for some common fault, the reasons for the failure and determines the           
method of fault. General operators can determine their own fault and note, maintenance it according to the           
brochure. But please contact the repairing agents when meeting a special note or not listed failure of operation.           
Please remember the following suggestions before repairing:           
- Make sure that study the failure carefully before any operation.           
- Repair with the easiest way and most commonly used method.           
- Find the exact causes of failure and completely solve the fault.     
   

1. Generator Sets          
Description of this section is for reference only. If the following failure occurs please contact the repairing agents.           
(Some models of control panel installed only parts of the following warning indicator light)
IconIndicator LightReasonFault Analysis
Low oil pressure
alarm
Low oil pressure
alarm
When oil pressure does not
reduce normally, the light is on.
-General because of a lack of oil or lubrication
system failure caused by (refueling or replacing
the oil filter)
-When occurs this fault should automatically
shutdown generator sets immediately.
High water
temperature
alarm
High water
temperature
alarm
When the water temperature
has risen to a level higher than
or equal to the sensor setting,
the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Low fuel level
alarm
Low fuel level
alarm
When a fuel level has been
detected by the sensor fitted to
the daily tank, the light is on.
-General because of a lack of water or oil
shortage, or overload.
-When occurs this fault should automatically
shutdown generator sets immediately.
Battery charger
fault alarm
Battery charger
fault alarm
If the charging system has fault,
when engine running, the light is
off.
-Battery charging system fault caused.
-The light is on at the initial start, when the
charger reaches a certain speed, the light is off.
-This failure will not lead to automatic shutdown
generating units.
Crank failure
alarm
Crank failure
alarm
When the generator set failed
three times (or six times) in a
row starting, the light is on.
-Oil supply system or re-start the system failure
caused.
Overload or
breaker tripping
alarm
Overload or
breaker tripping
alarm
When overloading or Short
circuit, the light is on. Tripping
circuit breakers cause generator
set load out.
-In this fault, it need to load or unload some parts
to eliminate short-circuit, and then re-close the
circuit breaker.

Introduction of Maintenance grade(Interval) for the generator set 
A Level Maintenance Interval (Daily Maintenance)
1. Check Daily Report of Genset .
2. Check fuel level and coolant level. 
3. Check alternator for cracks or other damage, and the condition of the belts must be checked, flab or 
other damage.
4. Check the Air filter. The air filter should be replaced when necessary .
5. Release fuel tank and fuel filter's water and sediment.
6. Check the water cooling filter.
7. Check starting battery and electrolyte, add electrolyte when necessary. 
8. Check the starter, check noisy defect.
9. Use air syringe cleaner to clean the water tank, coolant system and cooled fin net.
B Level Maintenance Interval (Less than 400 hours)
1. Repeatedly check A Level Daily Maintenance steps.
2. After operating 100 to 250 hours, replace the fuel filter. All the fuel filters should not be cleaned, it 
should be replaced. 100 to 250 hours is just flexible time, actually it must be according to the practice 
and real fact. 
3. After operating 200 to 250 hours, replace the oil & oil filter. All the lube oil must fit up to the CF 
Grade of American Petroleum Institute.
4. After operating 300 to 400 hours, replace the air filter. The air filter can be cleaned with air syringe, or 
it can be replaced. The replacement must be according to the environment and real fact.
5. Replace the cooling system and add coolant concentration.
6. Clean the crankshaft and inlet, outlet air- filter net. 
C Level Maintenance Interval (2000-3000 hours), Please do as follows:
1. Repeatedly check A and B Level Daily Maintenance steps.
2. Remove the tap of valve, clean and wash oil dirt and sludge.
3. Fasten snails from each part (including running parts and fixed parts)
4. Clean and wash the crankcase, oil sludge, steel scraps and sediment with engine.
5. Check wearing of the engine turbo, clean and wash accumulation of carbon, adjust it when necessary.
6. Check and adjust valve clearance.
7. Check PT pump, quality of injection, adjust injection process, adjust it when necessary.
8. Check and adjust the tension of fan belt and water pump belt, adjust and replace it when necessary; 
clean and wash water tank radiator fins, then check the using capability of thermostat.
Current Repair (D Level Maintenance)(3000-4000 hours)
1. Check valve, valve seat and other wearing, repair or change it when necessary.
2. Check P pump, quality of injection, repair and adjust it when necessary.
3. Check and adjust connecting rod and fastening twisting torque.
4. Check and adjust valve clearance.
5. Check the trip of injector.
6. Check and adjust tension of fan and generating belt.
7. Clean and wash accumulation of carbon in inlet pipes.
8. Clean and wash the core of air cooler.
9. Clean and wash the whole oil lubrication system.
10. Clean and wash room of rocker arm, oil sludge in the sump and Metal scrap-iron.
Medium Repair (6000-8000 hours)
1. Including the items of minor repair.
2. Disassemble generator(except crankshaft)
3. Check the easy worn spare parts in pitman shaft system, gas distribution system, lubrication system, 
cooling system of cylinder, Piston, Intake and exhaust valve, replace them when necessary.
4. Check fuel supplying system, adjust oil pump and injector.
5. Repair and test the alternator, clean oil-sediment and lubricate the bearing of alternator.
Overhaul (9000-15000hours)
1. Including the items of intermediate repair.
2. Disassemble all the parts in the generator.
3. Replace cylinder, piston, piston loop, big and small bearing bushes, trusting pad of crankshaft, intake 
and exhaust valve, a whole set of tools for generator repair 
4. Adjust oil pump, injector and replace pump core, injector
5. Replace a whole set of repair tools for turbo charger and a repair set for water pump.
6. Adjust the parts of connecting rod, crankshaft and generator body,repair or replace them when necessary
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA