Factory Price or Siemens Qra50m UV IR Flame Detector Sensor for Industrial Combustion Heating

Price $1796.00 Compare
Min Order 1 Piece
Shipping From Guangdong, China
Popularity 309 people viewed
Quantity
+-
 

Shenzhen YHG Heating Science & Technology Co., ltd

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
QRA50M
Industrial Gas Burner
ISO, CE
New
Ultra Quiet
Flame Detector
Control Gas
Qra50m
Siemens
Flame Detector
Normal
No
2-7days
EXW/Fob
Black and Golden
Gas Burner Accessories
Video Technical Support
Hydrogen, Nitrogen, Ng
Small
Siemens
Carton
10*9*8CM
Germany
8403900000
Product Description
Factory Price OR Siemens QRA50M UV ir Flame Detector  Sensor For Industrial Combustion Heating 

Application

This type of flame detector monitors the flame signal produced by UV radiation emitted by a gas or oil flame. The radiation detector is a UV phototube with 2 electrodes, which when illuminated by light in the 190...270 nm range of the spectrum will  initiating current in the flame detector circuit. UV does not react to hot refractory bricks in the combustion chamber, sunlight or lighting rays.
Model
  QRA50M
Brand
Siemens
  Name  Flame Detector
Usage
Gas burner accessories



Unit:mm

 Warning notice
To avoid personal injury, property damage and environmental damage, the following warning notices must be observed!
Do not open, interfere with or modify the flame detector! • All activities (installation, assembly and service work, etc.) are to be carried out by professionals
• Fully isolate the equipment from mains (all two stages disconnected) before making any wiring changes in the detector's connection area.
• Provide adequate protection to connection terminals from electrical shock.
• Check to make sure the wiring is properly connected.
• Halogen lamps, welding equipment, special lamps, or ignition sparks may generate enough radiation to cause the detector's UV Unit is lit. X-rays and gamma rays can also cause false flame signals.
• A fall or impact can affect the safety function. Such detector units do not work, even though they appear to be No damage at all. Installation Precautions
• Ensure compliance with relevant national security rules Installation Guide
• Controller unit and other cables must be installed separately from high voltage ignition cables Electrical connections for flame detectors To exclude interference, it is important to avoid losses in signal transmission:
• Do not run detector cables with other cables - Line capacitance reduces the level of the flame signal - Use a separate cable
• Observe the permissible length of the detector cable.

 



 