Fixed High Voltage Metal Glaze Film 1/4W 1r-3r Resistor

Price $1.10 Compare
Min Order 1 Kpcs
Shipping From Guangdong, China
Popularity 207 people viewed
Quantity
+-
 

Jiangmen Youxiang Electronics Co., Ltd

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
1/4W
Fixed Resistor
Protective Resistor, Load Resistor
DIP Resistor
Metal Film Resistor
Throught Hole
Thermal Resistor
Single Connection
Cylinder
Linear Scale
Medical Apparatus and Instruments
Hqswe
1r-3r
5% 10%
HQSWE
Carton
1/4W
Guangdong, China
Product Description
Detailed Photos



 
Package




 
Product Size Diagram

WATTSLDHd ±0.05mPULLING
(Kg)
MF1/8W /1/4WS3.5±0.31.8±0.328±2.00.382.5Kg-30S
MF1/4W / 1/2WS6.0±0.52.3±0.3s27±2.00.382.5Kg-30S
MF1/2W / 1WS9.0±1.03.5±0.526±2.00.482.5Kg-30S
MF1W / 2WS11.0±1.04.0±0.524±2.00.553Kg-30S
MF2W / 3WS15.0±1.05.0±0.533±2.00.655Kg-30S
MF3W /5WS17.0±1.06.0±0.532±2.00.75Kg-30S
MF5W24.0±1.08.0±1.028±2.00.85Kg-30S


 
Product Structure Diagram


 
Performance Test
 
ITEM (STANDARD)PERFORMANCE AND/OR
QUALIITY ACCEPTANCE
TEST METHOD

Resistance value Vs
Temperature
Characteristics




±100PPM/ºC


 
JIS-C-5202 5.2
Measure resistance (Ro ohm) at room
Temperature(To  ºC)
Measure again the same at 100ºC
Higher then room temperature
      R - RO           106
PPM =         *
       RO         (T0+100) -T0


 
ITEM (STANDARD)PERFORMANCE AND/OR
QUALIITY ACCEPTANCE
TEST METHOD

Short time overload

The resistance variation shall be
within±(0.5% + 0.05ohm) and there
Shall be no mechanical breakage




 
JIS-C-5202 5.5
Apply DC voltage 2.5times the rated
Voltage for 5 seconds
 The leave at room temperature for 30
Minutes then measure MAX overload
Voltage 0.50W - 700V (DC)

Insulation resistance

10,000M ohm or more
JIS-C-5202 5.6  in V-BLOCK
Lay the resistor on 90° angle metal V
Block apply 500VDC between resistor
Lead and V block for one Minute And
Measure

Voltage endurance

The resistance variation shall be
within±(0.5% + 0.05ohm) and there shall
Be no mechanical breakage
 
JIS-C-5202 5.7
Icy the resistor on the 90° angle metal V
Block and apply reamed AC voltage for
One Minute. Test voltage
0.25W - 500V (AC)  0.50W -700V(AC)

Intermittent overload

Resistance variation shall be
Within ±(0.50% + 0.05ohm)
JIS-C-5202 5.8
Apply AC voltage 4 times the rated voltage for 1 second and rest for 25 seconds and Repeat this cycle for 10000±200times leave resistor 30 minutes at room temperature after test and measure
Maximum voltage for intermittent
Overload.0.50W - 700V(AC)
 
Terminal strength
 
Resistance variation shall be within
±(0.5% + 0.05ohm) also there
Shall be on mechanical breakage

Pull test apply 2.5kg force to the lead in the direction of lead axisfor30±5 seconds.


Heat resistively
Against soldering


Resistance variation shall be within ± (0.25%+0.05ohm) also there
Shall be on mechanical breakage

JIS-C-5202 7.10
Dip the lead in to a solder bath having a
Temperature of 350ºC ± 10ºC up to 4±0.8mm from the body of the resistor  and hold it for 3±0.5seconds leave the resistor at room temperature 3 hours after ,then Measure

Load life test

The variation of the resistance
Shall be within ± (1.5%+0.05ohm)
Also there shall be no mechanical
Breakage

JIS-C-5202 7.10
In the constant temperature chamber having Temperature70ºC ± 2ºC,apply rated Dc voltage for 1.5hour and shut voltage for 0.5 hour and repeat this cycle for 1000 hours,leave in room temperature hour after test, then measure

EM (STANDARD)

PERFORMANCE AND/OR
QUALITY ACCEPTANCE

TEST METHOK

Solder ability

More than 95% of the surface of the lead shall be covered by new solder after the leads are dipped in the
Solder
JIS-C-5202  6.5
Dip the lead in to a solder bath having a
Temperature of 260ºC±5ºC up to 4±0.8mm from the body of the resistor and hold it for 5± 0.5seconds then inspect

Humidity load test

Resistance variation be
 Within ± (1.5% + 0.05ohm)
Also there shall be no mechanical breakage
JIS-C-5202 7.9
In temperature chamber having temperature 40ºC±2ºC,relative humidity 90 - 95%,Apply rated voltage 1.5hour and shut voltage 0.5 hour repeat this cycle for 1000 hours, leave in room temperature for hour after test, then measure
 

 
Rated Power Decline Diagram