Foundation Pile Dynamic Detector

Price $4685.00 Compare
Min Order 1 Set
Shipping From Beijing, China
Popularity 463 people viewed
Quantity
+-
 

Beijing ZBL Science and Technology CO., LTD.

VIP   Audited Supplier 3 years
Profile Certified by SGS/BV
ZBL-P8100
Factory Supply Service
Three Years
ZBL
Carton Box Outside, Protect Box Inside
7 kg /43*16*36 cm
Beijing, China
9031809090
Product Description
ZBL-P8100 Foundation Pile Dynamic Detector
Field of Use
  • The P8100 Foundation Pile Dynamic Detector is used to assess the integrity of concrete pile and identify the extent and location of the pile defects by using reflected wave method.
  • It can be used for testing bored concrete pile and hammer pile and also for testing the structures with exposed top surface such as pillars.
Basic Principle

Hit the top of pile with testing hammer to produce stress wave, and the wave may reflect when it meets defect (pile bottom, crack, or soil middle layer) while it run downward through the concrete. The probe placed on the top of the pile receives the reflected signal. The instrument digitally processes the signal in order to judge the quality of foundation pile. According to the time interval between the arrival of the direct wave and first reflected wave, or time interval between the two continuous reflected waves, the depth of foundation pile can be determined by the following equation: D= VP×TP/2

(D - depth of foundation pile, VP - compression wave speed, TP - compression wave spread time)



Features
  • Two-channel design can measure reflected wave speed accurately, and it can collect reflected wave at two places.
  • True 24 bit A/D data acquisition provides high resolution waveform avoiding the noise and signal distortion.
  • 1MHz high-speed data acquisition makes the minimum sampling time resolution reach 1us, providing more useful information and contributing to the discovery of shallow defects.
  • High Brightness and TFT colorful LCD screen.
  • Store waveform images for each tested pile.
  • New wavelet processing method can effectively judge the integrity of foundation pile in complex situation.
  • Water-proof; protection class reaches IP65.
  • Key and touch screen

Technical parameters
 
ItemSpecifications
ModelZBL-P8100
Control ModeA8 Embedded platform
Screen5.7 inch,High brightness, TFT color LCD screen
Data Storage≥4GB
Operation Modekey+touch screen
Sentinel magnify (time)1,2,5,10,20,50,100 adjustable
A/D resolution (bit)true 24 bits A/D
Sampling time intervals(μs)1~64000 adjustable
Max length of sampling4096
TriggerSignal trigger,
Noise voltage of the system (mV)≤1
Dynamic range(dB) ≥184
Amplifier frequency range(Hz)10~10k
Max storage length4096
Amplitude nonlinear degree≤10%
Time value error≤1%
Time resolving power(us)1
Gain error(dB)≤1
Continuous working time(h)>5
Number of channels2
Interference between the channels≤1%
Transducer/Probe Sensitivity
(acceleration mode)(mv/g)
≥100
Frequency range of Probe
(Acceleration probe) (Hz)
0.5 ~ 9000
Transmission portdouble USB
Wi-fiyes
PowerBuilt-inbattery
Outside220V AC/DC
Weight(kg)1.3(lithium battery included)
Size(mm)210×149×60
Operational
evvironment
Temperature(ºC)-10 ~+50
Humidity(RH)< 90%
 