Fpv, Fpvx, Fpvr, AC Voltage Transducers

Price Negotiable Compare
Min Order 4 Pieces
Shipping From Zhejiang, China
Popularity 287 people viewed
Quantity
+-
 

Haiyan Jinhan Import-Export Co., Ltd.

VIP   Audited Supplier 11 years
Profile Certified by SGS/BV
FPV, FPVX, FPVR
AC Voltage
AC Voltage Transmitter
Analog Output
Single
0.2G
ISO
Customized
Haiyan Jinhan Electronic Technology Co.,Ltd
Jinhan
1 Piece
Fpv-Vn-Fn-Pn-on
Global
Integration
Iron-Shell
About 0.5kg
by Air
Screws
JINGAN
Independent Package
SGS
Zhejiang, China
9030390000
Product Description
Applied Standards&Rules

     Measuring and conversion IEC 688 / 1992 - 04
     Dielectrical strength IEC 688 2KVac / 1 min.
     Surge and Impulse test ANSI C37.90 / 1989
     IEC 255-3 (1989) 4KV 1.2 x 50 us
 
Models

       FPV      1 unit of avg. to rms conversion
       FPVX   3 unit of avg. to rms conversion
      FPVR   Ture rms conversion

 
Order form

Input &Output parameters


Py : DC24 / 48 / 125 V ± 20% or other range under specified

Note:
  1. External power mode suitably for all output types
  2. Internal power mode, only suitably for 0-1mA / 0-20mA / 0-1V / 0-5V / 0-10V output
 
Specification

Accuracy ( 23±3°C )         0.2% RO .......... FPA, FPAX, FPV, FPVX                             
                                             0.2% RO .......... FPAR, FPVR                                    
Maximum output load              DC current mode : maximum 10V drop                             
                                             DC voltage mode : maximum 5mA drive                             
Dielectric strength                  AC 2KV 1 minute between terminals; AC 2.6KV 1 minute / terminals to case
Surge and impulse test           ANSI C37.90 / 1989, IEC 255-3 (1989) 4 KV 1.2 x 50 us
Maximum input over              Current related input                                               Voltage related input
                                                    1A / 5A                                10A                                                            
                                            4 x rated / continuous       2 x rated / continuous              1.5 x rated / continuous
                                           10 x rated / 10 seconds     25 x rated / 1 second               2 x rated / 10 seconds
                                            50 x rated / 1 second        50 x rated / 0.5 second       
                                            80 x rated / 0.5 second                                                                  
Input burden             Current less 0.2 VA; voltage less 0.1 VA                             
Response time & ripple     Ø400 ms for step change 0-99%               ripple less 0.5% ro peak to peak
Frequency                            45 ~ 400 Hz                                                                
Stability                              Temperature range ( 20 to 30°C )             long term stability / year
                                          Maximum 60 ppm / °C     less 0.2% draft / year typically
Storage condition              Temperature range -25 to 70°C, RH 20 to 95% non condensed
Operating condition          Temperature range -20 to 65°C, RH 0 to 99% non condensed
Magnetic field effect          < 0.01% under 100 ampere turns at 1M center           
Power dissipation            Maximum 3.5 VA for FPA / FPAR / FPV / FPVR; 8 VA for FPAX / FPVX

 
Terminal Connection



Model and Ordering
 FPV-Vn-Fn-Pn-On

Example:
 
1. FPV-V1-F1-P2-03

Input:120V
Auxiliary Frequency:50Hz
Power:AC 220V
Output:4-20mA

If you have any questions about this,welcome to contact us.
We are all at service.


We can provide the product model and specifications:
 
ProductModel No.
AC current transducerJD194-BS4I-N
AC voltage transducerJD194-BS4U-N
AC current transducerJD194-BS4I
DC current transducerJD194-BS5I
AC voltage transducerJD194-BS4U
DC voltage transducerJD194-BS5U
Power transmitterJD194-BS4P
Power transmitterJD194-BS4Q
Power factor transducerJD194-BS4H7
Frequency transmitterJD194-BS4F7
Integrated transmitterJD194-BS4Z6
Integrated transmitterJD194-BS4Z8
Integrated transmitterJD194-BS4Z-S
Temperature transmitterBS6T
Resistance transducerBS6R
Intelligent signal conditionerBS6M
AC current transducerRPA
AC voltage transducerRPV
AC current transducerRPAT
AC voltage transducerRPVT
AC current transducerRPAX
AC voltage transducerRPVX
Power transmitterRPW
Power transmitterRPK
Power transmitterRPWK
Power factor transducerRPPF
Frequency transmitterRPF
Frequency transmitterRPFT
AC current transducerCPA
AC voltage transducerCPV
AC current transducerCPAT
AC voltage transducerCPVT
AC current transducerCPAX
AC voltage transducerCPVX
Power transmitterCPW
Power transmitterCPK
Power transmitterCPWK
Power factor transducerCPPF
Frequency transmitterCPF
Frequency transmitterCPFT
Power transmitterFPW
Power transmitterFPK
Power transmitterFPWT
Power transmitterFPKT
Power transmitterFPWK
DC transducerFPD-1H
DC transducerFPD-2H
DC transducerFPDH-1H
DC transducerFPDH-2H
AC current transducerFPA
AC voltage transducerFPV
AC current transducerFPA2
AC voltage transducerFPV2
AC current transducerFPAR
AC voltage transducerFPVR
AC current transducerFPAT
AC voltage transducerFPVT
AC current transducerFPAX
AC voltage transducerFPVX
AC current transducerFPAX2
AC voltage transducerFPVX2
AC current transducerGPA
AC voltage transducerGPV
AC current transducerGPA2
AC voltage transducerGPV2
AC current transducerEPA
AC voltage transducerEPV
AC current transducerGPAT
AC voltage transducerGPVT
AC current transducerGPAX
AC voltage transducerGPVX
AC current transducerGPAX2
AC voltage transducerGPVX2
AC current transducerGPAS
AC voltage transducerGPVS
Generator negative sequence current meterFPFX-100
Temperature transmitterFT3
Temperature transmitterFT2
Temperature transmitterFT2-C
Temperature transmitterGPT
Temperature transmitterEPT
Shift transmitterFPB

Share This Story, Choose Your Platform!

Detailed Photos

 



Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA