FPW201, FPK201, FPW301, FPK301
New-Type Transmitter
AC Transmitter
Three
Three-wire Transmitter
0.2G
ISO
Customized
Haiyan Jinhan Electronic Technology Co.,Ltd
1 Piece
Global
Integration
Iron-Shell
172.5*126*89
About 2kg
by Air
2 Weeks
Screws
JINHAN
Independent Carton Package
SGS
China
9030390000
Product Description
                      WATT & VAR TRANSDUCER
 
Applied Standards&Rules

         Measuring and conversion IEC 688 / 1992 - 04
         Dielectrical strength IEC 688 2KVac / 1 min.
         Surge and Impulse test ANSI C37.90 / 1989
         IEC 255-3 (1989) 4KV 1.2 x 50 us

 
Models

Order form


Note
1.Standard output calibration

   bipolar 0 to ± 1mA for 0 to ± D Watts or Vars 4-12-20mA for -D to 0 to +D Watts or Vars
2. External power mode suitably for all output types

Internal power mode, only suitably for 0-1mA / 0-20mA / 0-1V / 0-5V / 0-10V output








Main functions and Characteristics
Transforms the measured signal to a voltage, after HCNR200 linearity photodiode transforms to DC output which has extremely good linear relations with the measured signal, uses the computer aided designed, the principle is simply, circuitry designed concisely, reliability is highly and installment is conveniently.
Notice
  Operating environment should not have the electric dust and gas of corrosive metal and destruction insulation existence, the altitude should less than 2,500 meters.
  The Zero and SPAN have been adjusted when products left factory. Please don't adjust at will.
 
 Technical Specification  
Reference Standard   
 
GB/T 13850-1998(IEC688-1992) 
 
Accuracy 
Long Term stability ≤±0.2%/year.No accumulation error
Temperature influence≤ 100ppm/oC
Response Time
 
  <400ms
 
Output Ripple<0.4%(peak-peak value)
 
Input burdenCurrent less 0.2VA;voltage less 0.1VA
 
 Frequency Nominal frequency ±10%
 
Maximum output loadCurrent output Max10V pressure drop
 
 Auxiliary power Ratedvoltage80%-120%,rated current 90%-110% 
Auxiliary load effect 
 
 <± 0.1% 
 
Allow excessive input Current 3rate continuous 10rate 30 secs voltageMax 2ratecontinuous 
 
Dielectric strengthInput /output /power/between the crust 2KV AC 1 minIEC866 
 
Impact testANSIC37.90a/1973,IEC255-4 (5kV1.2/50us PulsedVoltage) 
Calibration amplitudeFull scale least±3%,zero least±1%
 
Magnetic field effect0.4KA/m magnetic field strength change <0.05%
 
Operating condition Temperature -10~55oC relative humidity≤95%RHnoncondensing 
Storage condition Temperature -40~70oC relative humidity ≤95% RHnoncondensing 
 

Parameters:Customized
Input Voltage/Inout Current/Input Frequency/Auxiliary Power/Outout/Power Correction

We can provide the product model and specifications:
 
ProductModel No.
AC current transducerJD194-BS4I-N
AC voltage transducerJD194-BS4U-N
AC current transducerJD194-BS4I
DC current transducerJD194-BS5I
AC voltage transducerJD194-BS4U
DC voltage transducerJD194-BS5U
Power transmitterJD194-BS4P
Power transmitterJD194-BS4Q
Power factor transducerJD194-BS4H7
Frequency transmitterJD194-BS4F7
Integrated transmitterJD194-BS4Z6
Integrated transmitterJD194-BS4Z8
Integrated transmitterJD194-BS4Z-S
Temperature transmitterBS6T
Resistance transducerBS6R
Intelligent signal conditionerBS6M
AC current transducerRPA
AC voltage transducerRPV
AC current transducerRPAT
AC voltage transducerRPVT
AC current transducerRPAX
AC voltage transducerRPVX
Power transmitterRPW
Power transmitterRPK
Power transmitterRPWK
Power factor transducerRPPF
Frequency transmitterRPF
Frequency transmitterRPFT
AC current transducerCPA
AC voltage transducerCPV
AC current transducerCPAT
AC voltage transducerCPVT
AC current transducerCPAX
AC voltage transducerCPVX
Power transmitterCPW
Power transmitterCPK
Power transmitterCPWK
Power factor transducerCPPF
Frequency transmitterCPF
Frequency transmitterCPFT
Power transmitterFPW
Power transmitterFPK
Power transmitterFPWT
Power transmitterFPKT
Power transmitterFPWK
DC transducerFPD-1H
DC transducerFPD-2H
DC transducerFPDH-1H
DC transducerFPDH-2H
AC current transducerFPA
AC voltage transducerFPV
AC current transducerFPA2
AC voltage transducerFPV2
AC current transducerFPAR
AC voltage transducerFPVR
AC current transducerFPAT
AC voltage transducerFPVT
AC current transducerFPAX
AC voltage transducerFPVX
AC current transducerFPAX2
AC voltage transducerFPVX2
AC current transducerGPA
AC voltage transducerGPV
AC current transducerGPA2
AC voltage transducerGPV2
AC current transducerEPA
AC voltage transducerEPV
AC current transducerGPAT
AC voltage transducerGPVT
AC current transducerGPAX
AC voltage transducerGPVX
AC current transducerGPAX2
AC voltage transducerGPVX2
AC current transducerGPAS
AC voltage transducerGPVS
Generator negative sequence current meterFPFX-100
Temperature transmitterFT3
Temperature transmitterFT2
Temperature transmitterFT2-C
Temperature transmitterGPT
Temperature transmitterEPT
Shift transmitterFPB