Water Boiler, Steam Boilers, Hot Water Boiler, Oil Boiler, Hot Air Boiler
Oil-Fired
Bulk Boiler
Fire Tube
Steam and Water
Vertical Boiler
Pressure
Chamber Combustion Boiler
Industrial, Home, Power Station
1
30 Days
No
Light Weight
Weifu
Wooden Packaging
Customized
Jiangsu
Product Description
fully premixed low nitrogen condensing gas cast aluminum module boiler
1.Control system: The microcomputer monitors the operating status of the equipment in multiple channels in real time to ensure safe operation.
2. LCD display panel: Real-time display of boiler status, power, fault code, etc.
3. Multiple operating modes and timing functions: It has multiple functional modes such as winter and summer conversion mode, economic mode, holiday mode, and appointment timing function.
4. Full premixed combustion condensation technology: Compared with ordinary boilers, the thermal efficiency is improved by 15-20%.
5. AC variable frequency fan and zero pressure combination valve system: Quickly and accurately adjust the boiler load according to changes in heat demand, accurate and efficient energy saving.
6. Surface combustion technology: Metal fiber burner, nitrogen oxide emissions are less than 30mg/m3.
7. It has multiple safety protection functions: and the fault code is automatically displayed, indicating the fault status, which is conducive to troubleshooting.
8. Low water level protection: The water level electrode holder monitors the heating system in real time to prevent the system from lacking water.
9. Power supply voltage protection: When the main voltage is too low, the boiler cannot operate normally; gas pressure protection: When the gas pressure is abnormal, the gas proportional valve is automatically closed.
10. Flameout protection: When the burner fails to ignite or the flame goes out unexpectedly, the gas boiler is quickly shut down.
11. High temperature protection: When the water temperature in the boiler body is detected to be overheated, the gas boiler is automatically shut down.
12. Chimney abnormality protection: When the fan is abnormal or the smoke pipe is blocked, the gas boiler is automatically shut down.
13. Antifreeze protection: When the water supply temperature is lower than 7°C, the circulation pump starts to run; when the water supply temperature is lower than 3°C, the boiler will run at minimum power until the water supply temperature reaches 10°C and the return water temperature reaches 5°C. After that, the boiler stops running, but the circulation pump continues to run for 15 minutes.
2. LCD display panel: Real-time display of boiler status, power, fault code, etc.
3. Multiple operating modes and timing functions: It has multiple functional modes such as winter and summer conversion mode, economic mode, holiday mode, and appointment timing function.
4. Full premixed combustion condensation technology: Compared with ordinary boilers, the thermal efficiency is improved by 15-20%.
5. AC variable frequency fan and zero pressure combination valve system: Quickly and accurately adjust the boiler load according to changes in heat demand, accurate and efficient energy saving.
6. Surface combustion technology: Metal fiber burner, nitrogen oxide emissions are less than 30mg/m3.
7. It has multiple safety protection functions: and the fault code is automatically displayed, indicating the fault status, which is conducive to troubleshooting.
8. Low water level protection: The water level electrode holder monitors the heating system in real time to prevent the system from lacking water.
9. Power supply voltage protection: When the main voltage is too low, the boiler cannot operate normally; gas pressure protection: When the gas pressure is abnormal, the gas proportional valve is automatically closed.
10. Flameout protection: When the burner fails to ignite or the flame goes out unexpectedly, the gas boiler is quickly shut down.
11. High temperature protection: When the water temperature in the boiler body is detected to be overheated, the gas boiler is automatically shut down.
12. Chimney abnormality protection: When the fan is abnormal or the smoke pipe is blocked, the gas boiler is automatically shut down.
13. Antifreeze protection: When the water supply temperature is lower than 7°C, the circulation pump starts to run; when the water supply temperature is lower than 3°C, the boiler will run at minimum power until the water supply temperature reaches 10°C and the return water temperature reaches 5°C. After that, the boiler stops running, but the circulation pump continues to run for 15 minutes.
Fully premixed condensing commercial cast aluminum module boiler parameter table | ||||||||
Modal | Unit | WFZZ-150S | WFZZ-240M | WFZZ-350M | WFZZ-700L | WFZZ-1100L | WFZZ-1400L | |
Rated Power | KW | 150 | 240 | 350 | 700 | 1100 | 1400 | |
Maximum gas consumption | m³/h | 17.5 | 24 | 35 | 70 | 110 | 140 | |
Rated working pressure | Mpa | Normal pressure | Normal pressure | Normal pressure | Normal pressure | Normal pressure | Normal pressure | |
Gas pressure | pa | 2500 | 3000-5000 | 3000-5000 | 3000-5000 | 3000-5000 | 3000-8000 | |
Gas type (natural gas) | 12T | 12T | 12T | 12T | 12T | 12T | ||
Gas connection | ND | 32 | 40 | 40 | 40 | 50 | 65 | |
power supply | 220V/50Hz | 220V/50Hz | 220V/50Hz | 220V/50Hz | 380V/50Hz | 380V/50Hz | ||
Load adjustment range | % | 30%-100% | 30%-100% | 30%-100% | 30%-100% | 30%-100% | 30%-100% | |
Exhaust temperature maximum load | ºC | <65 | <65 | <65 | <70 | <70 | <70 | |
Maximum load 80-60ºC Thermal efficiency | % | 98% | 98% | 98% | 98% | 98% | 98% | |
Maximum load 50-30ºC Thermal efficiency | % | 103% | 103% | 103% | 103% | 103% | 103% | |
30% load 50-30ºC thermal efficiency | % | 108% | 108% | 108% | 108% | 108% | 108% | |
Maximum water outlet temperature | ºC | 85 | 85 | 85 | 90 | 90 | 90 | |
Flue interface size | mm | φ200 | φ200 | φ200 | φ250 | φ250 | φ315 | |
Water inlet and outlet interface | DN | 50 | 50 | 50 | 100 | 100 | 100 | |
Hot water supply capacity (△T=20ºC) | m³/h | 5.2 | 10 | 13.7 | 30.1 | 47.3 | 60.2 | |
Maximum circulating water flow | m³/h | 10.4 | 23.6 | 10.4 | 60.2 | 94.6 | 120.4 | |
Condensate pH | 4.8 | 4.8 | 4.8 | 4.8 | 4.8 | 4.8 | ||
noise | dB | <50 | <50 | <50 | <50 | <50 | <50 | |
Maximum power consumption | KW | 0.25 | 0.4 | 0.43 | 1.9 | 4 | 6 | |
Reference heating area (60w/m³) | M² | 800-1700 | 2800-4600 | 3200-5300 | 11000 | 18000 | 23300 | |
weight | KG | 138 | 258 | 269 | 570 | 720 | 1000 | |
Box size | Length | mm | 1000 | 1400 | 1400 | 1800 | 2300 | 2600 |
Width | mm | 800 | 800 | 800 | 1000 | 1000 | 1000 | |
Height | mm | 1340 | 1340 | 1340 | 1340 | 1340 | 1340 |






1. How to buy a good boiler?
A: Choose a good supplier.
B: Specification is clear, steam or hot water, capacity,fuel,pressure and so on
C:Price is not the only problem, quality and service also important.
2. What is your main product?
A:Steam boiler, hot water boiler and thermal oil boiler.Gas fired boiler, oil fired boiler, diesel fired boiler, coal fired boiler, biomass fired boiler,Industry boiler and so on.
3. Q: How long is your lead time?
A: Generally it is 30 days, depends on your needs and project scales.