 GDBR-P Transformer Capacity and Load no load loss Tester


General Information



GDBR-P is mainly used to test capacity, No-load current, No-load loss, short circuit(load) loss, impedance voltage for transformers.



Features
  1. Measure the capacity of various distribution transformers, which is convenient and accurate.
  2. Measure transformer No-load current, No-load loss, short circuit voltage and short circuit(load) loss.
  3. Automatic range switching is carried out inside the instrument, which allows a wide range of voltage and current measurements and simple wiring.
  4. When making three phase transformer No-load and load test, the instrument can automatically judge whether the wiring is correct or not, and display the vector diagram of three-phase voltage and current.
  5. Finish load test under 1000kVA below distribution transformer full current for single machine. Finish 3150kVA below distribution transformer load test under 1/3 rated current (Under 1/3 rated current, the instrument can be converted to load loss parameters under rated current.)
  6. All test results are corrected automatically. The instrument automatic correction as follows, waveform correction, temperature correction, non-rated voltage correction and non-rated current correction. The test results are more accurate.
  7. 320*240 high brightness LCD screen, with brightness adjustment. Touch buttons make the operation more convenient.
  8. The instrument can preset 40 sets parameters of test objects by users, and these parameters can be deleted and increased at any time according to need, so it is very convenient to use.
  9. Real-time clock, recording test date automatically, suitable for storage and management of test results.
  10. Built-in panel-type thermal printer, fast print test results.
  11. Power down store and browse data (test object settings, measurement results, test time) functions. Store up to 500 groups test results.
  12. Allows extended range measurement for external voltage transformer and current transformer. Measure test object of any parameters.


Specifications

Environment condition
 
  1. Temperature: -5ºC-40ºC
  2. Relative humidity: <95% (at 25ºC)
  3. Altitude: <2500m
  4. No vibration, no ultra-strong electromagnetic field
  5. Power input: AC220V± 10%, 45-55Hz.

Measurement range
 
  1. Internal source:
Current output: 0-10A
Voltage measurement: 0-10V
  1. Capacity test:
30kVA-2500kVA (for 10kV oil and dry transformers)
50kVA-31500kVA (for 35kV oil transformers)
50kVA-2500kVA (for 20kV dry transformers)
50kVA-2000kVA (for 35kV dry transformers)
 
  1. Measurement range of No-load and load test(need external voltage regulator, prepared by customer)
Voltage: 0-600V, automatic switching range.
Current: 0-100A, automatic switching range
Frequency: 45-65Hz.

Testing Accuracy
 
  1. Voltage: ±0.2%FS at 2-100V; ±0.2% at 100-600V
  2. Current: ±0.2%FS at 0.5-10A; ±0.2% at 10-100A
  3. Power: ±0.5% at cosφ>0.1; ±1.0% at 0.02<cosφ<0.1

Insulation strength
 
  1. Insulation resistance of Voltage and current input terminal to shell 100MOhm 
  2. Withstand voltage between power supply and shell is 2kV RMS, 1mins.
  3. Dimension: 400*300*220mm
  4. Weight: 6kg. (accessories are not included.)