GF6019d 1000V 100A 0.05% High Precision DC Energy Meter Test Equipment

Price $30000.00 Compare
Min Order 1 Set
Shipping From Beijing, China
Popularity 372 people viewed
Quantity
+-
 

Beijing GFUVE Electronics Co., Ltd.

VIP   Audited Supplier 12 years
Profile Certified by SGS/BV
GF6019D
24 Hour Service
3 Years
DC Energy Meter Test Equipment
Electricity
FDA, CE, IAF, CCC, Ilac.Mra
1000V
100A
None
None
With LCD Display
Customized
High Precision DC Energy Meter Test Equipment
0.05%, 0.1%
12kg
Touch TFT Color LCD
Yes
Yes
Yes
Yes
GFUVE
Standard Wooden Case
Dimensions (W× D× H) (mm) 495x390x195
China
Product Description

GF6019D 1000V 100A 0.05% HIGH PRECISION DC ENERGY METER TEST EQUIPMENT

The GF6019D high precision DC energy meter test equipment consists of an DC voltage standard source, DC current standard source and DC power source. (up to 1150V/600A) and built-in DC electronic reference standard of accuracy class 0.05%. Characteristic features of the GF6019D are its wide measuring range, high accuracy and high tolerance to unwanted external influences. The equipment offers high functionality combined with an excellent menu guided operation via built-in keyboards and colored 8" LCD-display. It can test DC energy meter basic error, starting test, creep test, error of time of day.

FEATURES

  • 0-100A/0-1150V;

    8 inch TFT touch screen;

    DC power source integrated;

    Test by automatic or manual;

    Accuracy class 0.05 or 0.02;

    Start testing and creep testing;

    Recorder 10000 sets energy meter data;

    Overload, short circuit, open circuit protection;

PARAMETERS

Electrical parameters
Accuracy0.05%; 0.02%
Power SupplyOne Phase AC 180-265V or 85-150V, frequency 50/60Hz.
DC Voltage Output
Range100V, 350V, 500V, 700V (max 800V);
65V, 250V, 500V, 750V, 1000V (max 1150V)
Adjustment range(0-120)%RG(1)
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability0.01%/120s
Distortion0.1% (Non-capacitive load)
Output load20VA or 50VA
Full load regulation rate≤±0.01%RG
Accuracy±(0.03%RD+0.02%RG)
DC Current Output
Range75mV, 2A, 20A, 50A, 100A;
0.001A, 0.005A, 0.02A, 0.05A, 0.2A, 1A, 3A, 10A, 20A, 50A, 100A, 500A (max 600A)
small signal 2.5mV, 20mV, 100mV, 1V, 5V
Adjustment range(0-120)%RG
Adjustment fineness0.01%RG, 0.1%RG, 1%RG, 10%RG as optional.
Stability<0.01%/120s
Distortion≤0.1% (Non-capacitive load)
Output load150VA or 1200VA
Full load regulation rate≤±0.01%RG
Accuracy±(0.03%RD+0.02%RG)
Externally attached shunt100mV
Accuracy±(0.06%RD+0.04%RG)
DC Power Output
power output stability<0.01%RG/120s
power accuracy±(0.03%RD+0.02%RG)
DC Power Energy Measurement Error
power energy±(0.03%RD+0.02%RG)
Power Pulse Output
Power Pulse Output20KHz (Full-Range)
Power Pulse Input
Energy pulse input20KHz
Ripple output20-500Hz ripple output
Communication portUSB port, RS232, 10/100M LAN
Mechanical parameters
Dimensions (W×D×H) (mm)460x460x175; 630x600x450
Weight (kg)22kg, 55kg
Environmental conditions
Ambient temperature-10°C to +40°C
Relative humidity35%-85%
(1) RG means range, the same as below;
(2) RD means the setted harmonic content, harmonic can be a single output, also multiple output.
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA