Product Description

GCS Power Distribution Switchgear Electricity Equipment

Certificates: ISO9001:2015,CE
OEM supplied.


GCS withdrawable low voltage electrical switchgear cabinet is an advanced low-voltage withdrawable switch cabinet. It has a compact structure, saves space, and is made of high-quality steel, which is sturdy and durable. It has perfect electrical performance and can realize power distribution and control. The withdrawable design is convenient for maintenance and does not affect the operation of other units. Multiple protection functions ensure safety and are a reliable choice for low-voltage power distribution systems.
Product Parameters
Rated voltage of main circuitAC380VAC/400VAC 660VAC
Rated voltage of auxiliary circuitAC24VAC,220VAC
DC24VAC,110VAC,220VAC
Rated frequency(Hz) 50/60Hz
Rated insulate voltage 660VAC/1000VAC
Rated current-horizontal busbar ≤4000A
Rated current-vertical busbar(MCC) 1000A
Rated short-time withstand current of busbar(kA/1s) 50,80
Rated peak withstand current of busbar(kA/0.1s) 105,176
Power frequency test voltageMain circuit2500
Auxiliary circuit2000
Busbar3P4WA,B,C,PEN
3P5WA,B,C,PE,N
IP rating IP30,IP40
 
Size Series
Height(mm)2200
Width(mm)6008001000
Depth(mm)800100060080010006008001000
Product Description

GCS power distribution cabinet adopts an assembled structure. The cabinet body is made of high-quality steel plate or aluminum alloy material, which has high strength and good corrosion resistance. Its structural design is compact and occupies a small area, making it suitable for installation in places with limited space. The interior adopts a partitioned structure to isolate units with different functions, improving the safety and reliability of the equipment. Each functional unit can be easily pulled out from the cabinet for inspection and maintenance without affecting the normal operation of other units.


GCS power distribution cabinet is mainly used in low-voltage power distribution system to realize the distribution, control and protection of electric energy. It has perfect electrical performance and can be installed with various electrical components, such as circuit breakers,contactors, relays, etc. to meet different power demand.It has intelligent control function, can monitor power parameters in real time, realize remote control and automatic operation.At the same time, it also has multiple protection functions such as overcurrent protection,short circuit protection,grounding protection,etc. to ensure the safety of electricity use.


GCS power distribution cabinets are widely used in various industrial and civil places, such as factories, shopping malls, hospitals, schools, residential communities, etc. They are suitable for low-voltage power distribution systems with an AC frequency of 50Hz and a rated working voltage of 380V, and can meet the needs of different loads. In some places with high space requirements, flexible configuration and easy maintenance, GCS power distribution cabinets have obvious advantages.


GCS power distribution cabinet has high reliability and stability. The selection and configuration of its electrical components have been strictly screened and tested to ensure reliable operation under various working conditions. It is easy to operate, the cabinet door is flexible to open, and the extraction and insertion of each functional unit are easy and convenient. The heat dissipation performance is good. Through reasonable ventilation design and heat dissipation devices, the internal electrical components are guaranteed to operate within the normal operating temperature range. In addition, GCS power distribution cabinet also has a good appearance design, which can be coordinated with the surrounding environment.

Enquiry

Kindly share these information when you send us enquiry:

1: The full range of product models includes the main circuit scheme number and the auxiliary circuit scheme number;
2: Main circuit system combination sequence diagram;
3: Electrical schematic diagram of auxiliary circuit;
4: List of components inside the cabinet;
5: Setting parameters such as voltage, current, and time in the circuit;
6: Other special requirements that do not comply with the normal use of the product.

Installation Instructions

The following is the installation guide for GCS withdrawable switchgear:
 
1) Preparation before installation
-Confirm that the installation site meets the environmental requirements of the switchgear, such as temperature, humidity, dust prevention, shock resistance, etc.
-Check the integrity of the switchgear and its accessories to ensure that there are no damaged or missing parts.
-Prepare the necessary installation tools and equipment, such as cranes, wrenches, screwdrivers, etc.

2) Basic installation
-Produce the foundation of the switchgear according to the design requirements, ensuring that the foundation is level and firm.
-Place the switchgear on the foundation, adjust the levelness and verticality, and fix it with bolts.

3) Connection of incoming and outgoing lines
-According to the electrical schematic, connect the incoming and outgoing cables to the corresponding terminals of the switchgear, ensuring a secure connection and good contact.
-When wiring, attention should be paid to the bending radius of the cable to avoid damaging the insulation of the cable.

4) Installation of drawer unit
-Insert the drawer unit into the guide rail of the switchgear to ensure smooth insertion and removal of the drawer.
-According to the design requirements, install electrical components in the drawer unit and wire them.

5) Grounding connection
-Ground the outer shell of the switchgear to ensure that the grounding resistance meets the requirements, in order to ensure personal safety and the normal operation of the equipment.

6) Secondary wiring
-Connect the control circuit, signal circuit, etc. according to the secondary schematic diagram.
-Check the correctness and reliability of the secondary wiring.

7) Debugging and Testing
-After installation, perform pre power on inspections, including wiring checks, insulation resistance tests, etc.
-Perform power on debugging and test various functions of the switchgear, such as opening and closing operations, protective actions, etc.

8) Acceptance
-After passing the debugging and testing, organize relevant personnel to conduct acceptance and confirm that the switchgear meets the design requirements and relevant standards.
 
During the installation process, relevant electrical safety regulations and operating procedures should be strictly followed to ensure installation quality and personnel safety. If you are unsure about certain steps during the installation process, it is recommended to consult a professional electrical engineer or technician.

Company Profile

FAQ

Q1: Are you a factory or trading company
A1: We are a factory, we can guarantee our price is first-hand, very cheap and competitive.

 
Q2: How does your factory do regarding quality control?
A2: All the products will be 100% checked before the shipment.

 
Q3: When can I get the price?
A3:Usually we quote within 24 hours after we get your inquiry.

 
Q4: What is the price of shipping?
A4: Depending upon the port of delivery, prices vary.

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA