Geteknet Intelligence 42u 600*1200*2000mm Smart Date Center Network Cabinets

Price $6999.00 Compare
Min Order 5 Pieces
Shipping From Zhejiang, China
Popularity 205 people viewed
Quantity
+-
 

Ningbo Geteknet Telecom Equipment Co., Ltd.

VIP   Audited Supplier 3 years
Profile Certified by SGS/BV
41D01
Network Cabinet
Video Surveillance Systems, Network Integration System, Remote Monitoring System, Closed-Circuit Monitoring System, Electronic Monitoring System, Wireless Monitoring System
Floor Standing
0
42u
CE, ISO, RoHS
New
SPCC Steel
42u 600*1200*2000mm
Tempered Glass Door / Solid Steel / Vented Door
Degreasing,Pickling,Phosphating,Powder Coated
OEM ODM
Dis-Assembled
1500KGS
Zhejiang Ningbo China
8537109090
Product Description

 

Product Description


Specification
*Rack-mounted 6kVA UPS customized ;
*9Ah Battery pack customized,
*Total backup time is 10-15 min;
*Rack-mounted distribution module customized
(Including C-level lightning protection, power monitoring)
*PDU customized;
*4.2KW Rack-mounted precision air conditioning customized
(including outdoor unit)
*AU Monitoring host and monitoring software
Difference
Gcabling Micro Data Center
Traditional Small Data Center
Computer Room
No need, fully enclosed with low noise, can be installed directly in the corner of office. Single cabinet occupies an area of 0.7-1.0m²
Need, occupying an area of about 10-20m²
Decoration
No need
Need
Operating Cost
Fully enclosed microenvironment, low energy consumption, with a PUE level around 1.5
Air conditioning cools the entire room, resulting in high electricity costs, with an overall energy efficiency level between 2.0 and 3.0
Management and Maintenance
One-stop service, with IT personnel available on a part-time basis
Multi vendor procurement, unclear responsibility interface, requiring maintenance and management by multiple professionals
Installation
Overall design, plug and play
UPS, Air conditioners and cabinets are independently purchased and installed
Construction Period
1-2 days
3-4 weeks
Aesthetics
Appearance of the devices is coordinated and unified
Poor consistency in appearance between devices
Cleanliness
Fully enclosed environment, cleanliness comparable to cloud computing rooms
Dependent on environmental conditions, long-term operation can easily accumulate dust, leading to device restart and downtime
Noise
Noise level of 55dB (A), with minimal impact on the environment
Noise level is 65-70dB (A), requires sound insulation treatment
UPS
Placed inside a sealed cabinet, with precision air conditioning to ensure operation
Independent UPS+battery cabinet, dependent on room temperature and cleanliness
PDU
Equipped with SPD, well-known brand switches, and intelligent monitoring of power status
Wall mounted installation, no guarantee of air switch brand, no monitoring, no SPD
Air Conditioner
Specialized precision air conditioning, 7×24 hour operation
Civil air conditioning does not match the needs of server operation, resulting in a high failure rate
Monitoring
Complete monitoring (temperature, humidity, smoke, water leakage, video, UPS, air conditioning, electricity, energy consumption,
email and SMS alerts), constantly monitoring the operating status
No monitoring or simple monitoring

 