ESSA Series
Air-Cooled
Air-cooled
Integral
220~460V-50Hz/60Hz-3pH
1,2,4
Low
Food Processing
Brewery
CE
New
Copeland
R407c, R404A
Polyurethane Coated for Anti-Corrosion
Microcomputer Control Punp
Danfoss, Emerson
Plate, Shell Tube, Coil in Tank
Aluminum Finned Copper Tube
Blue White
Stainless Steel, Unpressurized
Centrifugal Cnp
Optional Castel, Hongsen
Axial
OEM, ODM
ESACIR
Wooden Case
Chilled liquid outlet temp.: 0, -5, -10C
Shenzhen
8418692090
Product Description
Glycol Liquid Chiller Air Cooled Chiller For Cooling Fermentation Tank
1. Eurostars air cooled glycol chiller main components
(1)Hermetic scroll compressors-Copeland
(2)Stainless steel centrifugal pump
(3)Non ferrous water piping
(4)Stainless steel chilled water insulated tank
(5)Stainless steel evaporator (housed in tank); Plate and shell tube type is optional
(6)Electronic temperature controller with full feature controls
(7)Attractive and durable steel cabinet (SS casing is optional)
(8)Oil Separator is optional
(9)Designed for ease of accessibility to components
(10)Low ambient start-up package
(11)Split system (remote condenser) also available

2. Air cooled industrial glycol chiller applications
Brewery chillers are often glycol chillers. Good beer requires good process control. The ability to produce the same beer day-in and day-out is important in brewing. A brewery's most enthusiastic customers expect the same flavor that they have come to know and love, regardless of the batch that their beer comes from. Keeping those customers happy requires the excellent temperature control that can be achieved with a brewery chiller.
3. Air cooled glycol chiller flow chart system

4. Eurostars air cooled industrial chiller protection devices
(1)Motor overload protection
(2)Compressor motor overheat protection
(3)Discharge temperature overhigh protection
(4)High&low pressure protection
(5)Returning water overheat protection
(6)Low water flow/level protection
(7)Phase protection
(8)Anti-freezing protection
5. Eurostars air cooled glycol chiller brief technical data
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Remarks:
(1) Rated Cooling Capacity Based on:DB Temperature 35ºC/WB Temperature 24ºC.
(2)Chilled glycol-water liquid in/outlet temp. 5ºC/0ºC
(3)Chilled glycol-waterl iquid range: 0~10ºC; Ambient Temperature: 5ºC~43ºC.
6.Factory testing of Eurostars every chiller unit
(1)Pressurization and helium leak detection of refrigeration circuit
(2)Pressurization and leak testing of fluid circuit
(3)Chiller performance and power consumption at full load
(4)Proper operation of all controls, safety devices, and alarms
(5)Electrical tests according to standards

1. Eurostars air cooled glycol chiller main components
(1)Hermetic scroll compressors-Copeland
(2)Stainless steel centrifugal pump
(3)Non ferrous water piping
(4)Stainless steel chilled water insulated tank
(5)Stainless steel evaporator (housed in tank); Plate and shell tube type is optional
(6)Electronic temperature controller with full feature controls
(7)Attractive and durable steel cabinet (SS casing is optional)
(8)Oil Separator is optional
(9)Designed for ease of accessibility to components
(10)Low ambient start-up package
(11)Split system (remote condenser) also available

2. Air cooled industrial glycol chiller applications
Brewery chillers are often glycol chillers. Good beer requires good process control. The ability to produce the same beer day-in and day-out is important in brewing. A brewery's most enthusiastic customers expect the same flavor that they have come to know and love, regardless of the batch that their beer comes from. Keeping those customers happy requires the excellent temperature control that can be achieved with a brewery chiller.
Glycol Chiller Applications | How Glycol Chillers are Being Used |
Breweries | Cooling the Wort Controlling Fermentation Crash Cooling Vessels Prepackaging Product Storage |
Wineries | Fermentation Process Cold Stabilization Room Cooling |
Cider Mills | Fermentation Control Cold Chilling the Juice Cold Storage of the Final Product |
Distilleries | Fermentation Process Circulation Between Distillation Tanks & Stills Heat Removal |
3. Air cooled glycol chiller flow chart system

4. Eurostars air cooled industrial chiller protection devices
(1)Motor overload protection
(2)Compressor motor overheat protection
(3)Discharge temperature overhigh protection
(4)High&low pressure protection
(5)Returning water overheat protection
(6)Low water flow/level protection
(7)Phase protection
(8)Anti-freezing protection
5. Eurostars air cooled glycol chiller brief technical data
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Air Cooled Chiller Unit(R407C,0ºC) | ||||||||
Model ESSA- | 03ISBTY | 05ISBTY | 08ISBTY | 10ISBTY | 12ISBTY | 15ISBTY | ||
Rated Cooling Capacity | KW | 5.75 | 9.84 | 15.30 | 20.40 | 25.00 | 29.80 | |
USRT | 1.64 | 2.80 | 4.35 | 5.80 | 7.11 | 8.48 | ||
×1000 kcal/h | 4.95 | 8.46 | 13.16 | 17.54 | 21.50 | 25.63 |
Air Cooled Chiller Unit(R407C,0ºC) | ||||||||
Model ESSA- | 20IDBTY | 25IDBTY | 30IDBTY | 40IQBTY | 50IQBTY | 60IQBTY | ||
Rated Cooling Capacity | KW | 40.80 | 50 | 59.6 | 81.6 | 100 | 119.2 | |
USRT | 11.60 | 14.22 | 16.95 | 23.21 | 28.44 | 33.90 | ||
×1000 kcal/h | 35.09 | 43.00 | 51.26 | 70.18 | 86.00 | 102.51 |
(1) Rated Cooling Capacity Based on:DB Temperature 35ºC/WB Temperature 24ºC.
(2)Chilled glycol-water liquid in/outlet temp. 5ºC/0ºC
(3)Chilled glycol-waterl iquid range: 0~10ºC; Ambient Temperature: 5ºC~43ºC.
6.Factory testing of Eurostars every chiller unit
(1)Pressurization and helium leak detection of refrigeration circuit
(2)Pressurization and leak testing of fluid circuit
(3)Chiller performance and power consumption at full load
(4)Proper operation of all controls, safety devices, and alarms
(5)Electrical tests according to standards

7. How to size a glycol chiller for brewing?
These suggestions assume a decently insulated vessel (neoprene jacket or better) in a modest ambient temperature of 80F (27ºC). If your setup is uninsulated, or running in hotter ambient conditions you'll need to allow for more BTU/hr. The cold crash is figured for about 18hrs, if you want a faster crash you'll need to add more BTU/hr. When in doubt, use the suggestions for a vessel 1-2 sizes bigger than your actual size.
8. Eurostars Company Ceritifcate & Customer Visiting
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.


9. Our factory view
Modern new process and assemble line, including copper tube straighten machine, aluminum fin punching machine, three dimensional copper tube bending machine, tube expander machine, sheet metal laser cutting machine, numerical control punching machine, CNC bending machine, chiller, fan coil unit and AHU assemble line,. etc..


Chiller production at our previous location as below

10. Eurostars air cooled industrial chiller package and delivery
Our standard package is plastic film with plywood case for safe delivery and easy to load/unload.


11. Eurostars industrial chiller projects
We exported chillers to Ukraine, New Zealand, Guatelmala, Peru, Chile, Norway, Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Sri Lanka, India, Saudi Arabia, Iran, Mexico, Argentina, etc..


These suggestions assume a decently insulated vessel (neoprene jacket or better) in a modest ambient temperature of 80F (27ºC). If your setup is uninsulated, or running in hotter ambient conditions you'll need to allow for more BTU/hr. The cold crash is figured for about 18hrs, if you want a faster crash you'll need to add more BTU/hr. When in doubt, use the suggestions for a vessel 1-2 sizes bigger than your actual size.
Size | Fermentation Temps (65F) | During Cold Crash (35-45F) | Maintain Cold Temps (35-45F) |
7 gal | 60 BTU/hr | 300 BTU/hr | 120 BTU/hr |
14 gal | 90 BTU/hr | 600 BTU/hr | 180 BTU/hr |
1 BBL | 150 BTU/hr | 1000 BTU/hr | 300 BTU/hr |
2 BBL | 300 BTU/hr | 2000 BTU/hr | 600 BTU/hr |
3 BBL | 450 BTU/hr | 3000 BTU/hr | 900 BTU/hr |
5 BBL | 600 BTU/hr | 4300 BTU/hr | 1125 BTU/hr |
7 BBL | 850 BTU/hr | 6000 BTU/hr | 1600 BTU/hr |
10 BBL | 1100 BTU/hr | 8650 BTU/hr | 1900 BTU/hr |
8. Eurostars Company Ceritifcate & Customer Visiting
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.
Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.


9. Our factory view
Modern new process and assemble line, including copper tube straighten machine, aluminum fin punching machine, three dimensional copper tube bending machine, tube expander machine, sheet metal laser cutting machine, numerical control punching machine, CNC bending machine, chiller, fan coil unit and AHU assemble line,. etc..


Chiller production at our previous location as below

10. Eurostars air cooled industrial chiller package and delivery
Our standard package is plastic film with plywood case for safe delivery and easy to load/unload.


11. Eurostars industrial chiller projects
We exported chillers to Ukraine, New Zealand, Guatelmala, Peru, Chile, Norway, Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Sri Lanka, India, Saudi Arabia, Iran, Mexico, Argentina, etc..