ESSA Series
Air-Cooled
Air-cooled
Integral
220~460V-50Hz/60Hz-3pH
1,2,4
Low
Food Processing
Brewery
CE
New
Copeland
R407c, R404A
Polyurethane Coated for Anti-Corrosion
Microcomputer Control Punp
Danfoss, Emerson
Plate, Shell Tube, Coil in Tank
Aluminum Finned Copper Tube
Blue White
Stainless Steel, Unpressurized
Centrifugal Cnp
Optional Castel, Hongsen
Axial
OEM, ODM
ESACIR
Wooden Case
Chilled liquid outlet temp.: 0, -5, -10C
Shenzhen
8418692090
Product Description
Glycol Liquid Chiller Air Cooled Chiller For Cooling Fermentation Tank

1. Eurostars air cooled glycol chiller main components

(1)Hermetic scroll compressors-Copeland
(2)Stainless steel centrifugal pump
(3)Non ferrous water piping
(4)Stainless steel chilled water insulated tank
(5)Stainless steel evaporator (housed in tank); Plate and shell tube type is optional
(6)Electronic temperature controller with full feature controls
(7)Attractive and durable steel cabinet (SS casing is optional)
(8)Oil Separator is optional
(9)Designed for ease of accessibility to components
(10)Low ambient start-up package
(11)Split system (remote condenser) also available


2. Air cooled industrial glycol chiller applications
Brewery chillers are often glycol chillers. Good beer requires good process control. The ability to produce the same beer day-in and day-out is important in brewing. A brewery's most enthusiastic customers expect the same flavor that they have come to know and love, regardless of the batch that their beer comes from. Keeping those customers happy requires the excellent temperature control that can be achieved with a brewery chiller.
Glycol Chiller ApplicationsHow Glycol Chillers are Being Used
BreweriesCooling the Wort
Controlling Fermentation
Crash Cooling Vessels
Prepackaging
Product Storage
WineriesFermentation Process
Cold Stabilization
Room Cooling
Cider MillsFermentation Control
Cold Chilling the Juice
Cold Storage of the Final Product
DistilleriesFermentation Process
Circulation Between Distillation Tanks & Stills
Heat Removal

3. Air cooled glycol chiller flow chart system


4. Eurostars air cooled industrial chiller protection devices
(1)Motor overload protection
(2)Compressor motor overheat protection
(3)Discharge temperature overhigh protection
(4)High&low pressure protection
(5)Returning water overheat protection
(6)Low water flow/level protection
(7)Phase protection
(8)Anti-freezing protection

5. Eurostars air cooled glycol chiller brief technical data 
Please ask salesman for detailed complete data or visit our website:
eurostarschiller.en.made-in-china.com
eurostarschiller.en.made-in-china.com
Air Cooled Chiller Unit(R407C,0ºC)
Model     ESSA-03ISBTY05ISBTY08ISBTY10ISBTY12ISBTY15ISBTY
Rated Cooling CapacityKW5.75 9.84 15.30 20.40 25.00 29.80 
USRT1.64 2.80 4.35 5.80 7.11 8.48 
×1000 kcal/h4.95 8.46 13.16 17.54 21.50 25.63 
Air Cooled Chiller Unit(R407C,0ºC)
Model     ESSA-20IDBTY25IDBTY30IDBTY40IQBTY50IQBTY60IQBTY
Rated Cooling CapacityKW40.80 5059.681.6100119.2
USRT11.60 14.22 16.95 23.21 28.44 33.90 
×1000 kcal/h35.09 43.00 51.26 70.18 86.00 102.51 
Remarks:
(1) Rated Cooling Capacity Based on:DB Temperature 35ºC/WB Temperature 24ºC.
(2)Chilled glycol-water liquid in/outlet temp. 5ºC/0ºC
(3)Chilled glycol-waterl iquid range: 0~10ºC; Ambient Temperature: 5ºC~43ºC.

6.Factory testing of Eurostars every chiller unit
(1)Pressurization and helium leak detection of refrigeration circuit
(2)Pressurization and leak testing of fluid circuit
(3)Chiller performance and power consumption at full load
(4)Proper operation of all controls, safety devices, and alarms
(5)Electrical tests according to standards 
 
7. How to size a glycol chiller for brewing?
These suggestions assume a decently insulated vessel (neoprene jacket or better) in a modest ambient temperature of 80F (27ºC). If your setup is uninsulated, or running in hotter ambient conditions you'll need to allow for more BTU/hr. The cold crash is figured for about 18hrs, if you want a faster crash you'll need to add more BTU/hr. When in doubt, use the suggestions for a vessel 1-2 sizes bigger than your actual size.
 
SizeFermentation Temps
(65F)
During Cold Crash
(35-45F)
Maintain Cold Temps
(35-45F)
7 gal60 BTU/hr300 BTU/hr120 BTU/hr
14 gal90 BTU/hr600 BTU/hr180 BTU/hr
1 BBL150 BTU/hr1000 BTU/hr300 BTU/hr
2 BBL300 BTU/hr2000 BTU/hr600 BTU/hr
3 BBL450 BTU/hr3000 BTU/hr900 BTU/hr
5 BBL600 BTU/hr4300 BTU/hr1125 BTU/hr
7 BBL850 BTU/hr6000 BTU/hr1600 BTU/hr
10 BBL1100 BTU/hr8650 BTU/hr1900 BTU/hr

8. Eurostars Company Ceritifcate & Customer Visiting
We, EUROSTARS, which established in year 2006, is a modern hi-tech enterprise, specializing in Heating Ventilation Air Conditioning and Industrial Refrigeration research, development, production, sales and engineering services.

Eurostars team with more than 10 years experience of HVAC equipment and system in local China and international market, has provided qualified HVAC equipment, installation and service to 30+ countries around the world.




9. Our factory view

Modern new process and assemble line, including copper tube straighten machine, aluminum fin punching machine, three dimensional copper tube bending machine, tube expander machine, sheet metal laser cutting machine, numerical control punching machine, CNC bending machine, chiller, fan coil unit and AHU assemble line,. etc..



Chiller production at our previous location as below


10. Eurostars air cooled industrial chiller package and delivery

Our standard package is plastic film with plywood case for safe delivery and easy to load/unload.




11. Eurostars industrial chiller projects

We exported chillers to Ukraine, New Zealand, Guatelmala, Peru, Chile, Norway, Serbia, Romania, Greece, France, South Africa, Australia, Uzbekistan, Sri Lanka, India, Saudi Arabia, Iran, Mexico, Argentina, etc..

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA