SPH 4000-10000TL3 BH-UP
Yes
5 Years
Passive inverter
Three
>1000W
CE
Growatt
DC/AC Inverters
Solar Power
Push-pull Type
Sine Wave Inverter
97.4%
Fujian, China
1000V
230V/400V
6.1-15.2A
50/60Hz
28kg
Type II
<13W
Transformerless
Natural
IP65
0~100%
3000m
LCD LED
GROWATT
Wooden Box
505/453/198 mm
China
Product Description
Growatt Wholesale 10 Kw 5Kw Solar Inverter Pcb Board Three Phase Power Hybrid Inverter For Solar System Hybrid Solar Inverter
Product descriptions from the supplier
Specification | SPH4000TL3 BH-UP | SPH5000TL3 BH-UP | SPH6000TL3 BH-UP | SPH7000TL3 BH-UP | SPH8000TL3 BH-UP | SPH10000TL3 BH-UP |
Input data (PV) | ||||||
Max PV power (STC) | 6000W | 7500W | 9000W | 10500W | 12000W | 15000W |
Max DC voltage | 1000V | |||||
Start voltage | 120V | |||||
MPP Voltage range | 120V-1000V/600V | |||||
No. of MPP trackers | 2 | |||||
No. of PV strings per MPP tracker | 1 | |||||
Max. input current per MPP tracker | 13.5A | |||||
Max. short-circuit current per MPP tracker | 16.9A | |||||
Output data(AC) | ||||||
AC nominal power | 4000W | 5000W | 6000W | 7000W | 8000W | 10000W |
Max. AC apparent power | 4000VA | 5000VA | 6000VA | 7000VA | 8000VA | 10000VA |
Nominal AC voltage (range*) | 230V/400V (310~476V) | |||||
AC grid frequency (range) | 50Hz/60Hz (45Hz-55Hz/55Hz-65Hz) | |||||
Max. output current | 6.1A | 7.6A | 9.1A | 10.6A | 12.1A | 15.2A |
Adjustable power factor | 0.8leading…0.8lagging | |||||
THDi | <3% | |||||
AC grid connection type | 3W+N+PE | |||||
Battery data (DC) | ||||||
Battery voltage range | 100~550V | |||||
Max charging and discharging current | 25A | |||||
Continuous charging and discharging powe | 4000W | 5000W | 6000W | 7000W | 8000W | 10000W |
Type of battery | Lithium battery | |||||
Backup power(AC) | ||||||
Max. AC output power | 4000W | 5000W | 6000W | 7000W | 8000W | 10000W |
Max. AC apparent power | 4000VA | 5000VA | 6000VA | 7000VA | 8000VA | 10000VA |
Max. output current | 6.1A | 7.6A | 9.1A | 10.6A | 12.1A | 15.2A |
Nominal AC output voltage | 230V/400V | |||||
Nominal AC output frequency | 50/60HZ | |||||
THDv | <3% | |||||
Switch time | <10ms | |||||
Efficiency | ||||||
MAX. efficiency | 97.6% | 97.8% | 98.0% | 98.2% | 98.2% | 98.2% |
European efficiency | 97.0% | 97.2% | 97.3% | 97.4% | 97.4% | 97.5% |
Protection devices | ||||||
DC switch | Yes | |||||
DC reverse polarity protection | Yes | |||||
AC/DC surge protection | Type II | |||||
Battery reverse protection | Yes | |||||
AC short-circuit protection | Yes | |||||
Ground fault monitoring | Yes | |||||
Grid monitoring | Yes | |||||
Anti-islanding protection | Yes | |||||
Residual-current monitoring unit | Yes | |||||
Insulation resistance monitoring | Yes |




Packing Details : carton box , wooden box and wooden pallet , 1unit per carton box
Delivery Details : ship within 5days after payment