Guowang Factory Medium Voltage Copper Core 185/120/95mm2 XLPE Insulated Swa Power Cable

Price $50.00 Compare
Min Order 100 Meters
Shipping From Henan, China
Popularity 351 people viewed
Quantity
+-
 

Henan Guowang Cable Group Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
Customized
Construction, Underground, Industrial, Power Station
Low and Medium Voltage Cable
XLPE
PVC
Round Wire
Red Copper Wire
ISO, CCC, CE, VDE
Steel Wire
30%+70%
EXW, Fob, CIF
Guowang Cable Group
No
Wooden Drum
50-630mm2
China
8544601290
Product Description
Guowang Factory Medium Aluminum Voltage Copper Core 185mm2 120mm2 95mm2 XLPE/PVC Insulated SWA Power Cable for Construction

Product Description

This product is suitable for fixed laying in the distribution network with AC 50Hz and rated voltage 26/35kV or industrial installations.

Occasion
It is mainly used in the underground power grid of urban building communities, the leading lines of power generation and substations (all), and the use of power supply and distribution. For example, it can be used in power distribution and other places within industrial and mining enterprises.

Product Characteristics
It has the characteristics of high normal operating temperature of conductor, simple structure, easy to use and not limited by laying drop.
This product uses steel wire armor, can withstand large mechanical tension.

Detailed Photos

Rated voltage
The rated voltage is 26/35kV, and the maximum voltage using the AC system should not exceed 40.5kV.

Operating temperature
The maximum allowable working temperature of the cable conductor for a long time is 90ºC. In the case of short circuit, the maximum temperature of the cable conductor shall not exceed 250 ° C and the duration shall not exceed 5s.

Ambient temperature
The minimum ambient temperature for cable operation is
-10 ° C.

Laying temperature
When installing and laying, the temperature should not be lower than 0ºC.
 

Product Parameters

SizeConductor Structure
(MM)
Outer Diameter of Conductor
(MM)
Insulation Thickness
(MM)
Thickness of Outer Sheath
(MM)
Reference Outside Diameter
(MM)
Reference Weight
(KG)
3 x 5010/2.588.410.53.889.511609.8
3 x 7019/2.1810.010.53.993.412767.1
3 x 9519/2.5811.610.54.197.214114.4
3 x 12024/2.5813.010.54.2100.615448.2
3 x 15030/2.5814.610.54.3104.516909.7
3 x 18537/2.5816.210.54.4108.118463.6
3 x 24048/2.5818.510.54.6113.720958.2
3 x 30060/2.5820.610.54.7118.623497.6
3 x 40061/2.9423.810.55.0126.327416.0
1 x 5010/2.588.410.52.446.63855.9
1 x 7019/2.1810.010.52.548.24180.8
1 x 9519/2.5811.610.52.549.84584.3
1 x 12024/2.5813.010.52.651.44987.0
1 x 15030/2.5814.610.52.653.25444.1
1 x 18537/2.5816.210.52.755.05948.6
1 x 24048/2.5818.510.52.757.36685.0
1 x 30060/2.5820.610.52.859.87504.8
1 x 40061/2.9423.810.52.963.28664.9