Gw9-10/1250A Single-Phase Disconnector Ceramic Type

Price $75.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 279 people viewed
Quantity
+-
 

Zhejiang Maiyu Electric Co., Ltd.

VIP   Audited Supplier 2 years
Profile Certified by SGS/BV
GW9-15
High-voltage
Double-column Disconnector
Outdoor High-voltage
Manual
Not Grounding
Plug-in Type
Unipolar
Un Grounded
Single-Stage
Vertical Rotation
Single Throw-in
YR
Manual
ISO9001
Maiyu Electric
12kv
630A
14ka
25ka
Wooden Box
45*55*38mm
Yueqing City, Zhejiang Province, China
Product Description
Company Profile
Zhejiang Maiyu Electric Co. , Ltd. is a professional manufacturer, high voltage vacuum circuit breaker
series, indoor high voltage vacuum circuit breaker series, load switch series, lightning arrester series, high
voltage disconnector series, drop fuse series, grounding switch series, cable box series and other
electrical equipment companies, the company is composed of a group of people engaged in electrical
industry for many years, with professional technical research and development and product sales team,
perfect production equipment, integrity management, strict quality control.
Product Description

The "(H)GW9-12" outdoor high voltage switch equipment of single phase AC 50Hz.The product is suitable for power systems with a rated voltage of 10kV to make or break power supply under circumstances of voltage and no load. The isolator adopts an isolated hook rod to operate.
 

Service conditions
1. The altitude does not exceed 1000m.
2. The ambient air temperature: Maximum:+40ºC; Minimum:-30ºC, Paramos:-40ºC
3. The wind pressure does not exceed 700Pa. (corresponding to 34m/s wind speed).
4. The earthquake intensity does not exceed 8 degrees.
5. The working situation hasn't frequent violent vibration.
6. The installation site of an ordinary type isolator should be kept away from gas, smoke chemical deposition,salt-spray fog, dust, and other explosive and corrosive matters that affect seriously the insulation and conduction capability of the isolator.
7. Pollution-proof type isolator is applied to severe filthy conduction area; however, it shouldn't be any explosive matters and matters causing a fire.
Product Parameters
ModelRated voltage
(KA)
Current rating
(A)
The limit of the passing current
(KA)
4 seconds to heat
Stabilize the current
(KA)
peakValid values
          10
  (H)GW9-12W

          15
          DA
          24
10
12
15
24
240595
400211510
600352514
630352514
800352514
1000503524
125031.580 