Description
The loose tube are made of high modulus plastics(PBT), which are filled with water resistant gel. High strength glass yarn or aramid yarn wrapped which used for increasing crush resistance. Two FRP(Kevlar) strength member provide high tensile resistance. Outer sheath is made of UV resistance PE jacket.All dielectric cable construction allows hanging on electric poles and power lines with up to 12 KV.
Feature
1, All-dielectric cable construction
2, Unitube design. Up to 24fibers.
3, Suitable for outdoor and indoor usage
4, Compact structure, small size and light weight.
5, Water blocking, UV resistance, High and low temperature resistance.
6, Adopt strict process and raw materials control guarantee the lifespan more than 30 years.
Application:
For laying inside buildings, in risers, attics, basements, sewers and pipelines.
It's a good choise for last mile FTTX project.
Mechanical Performance:
Max Tension Performance: IEC 60794-1-2-E
Max. Operation Tension: IEC 60794-1-2-E1
Crush Test: IEC 6079 -1-2-E3
Impact Test: IEC 60794-1-2-E4
Repeated Bending: IEC 60794-1-2-E6
Torsion Test: IEC 60794-1-2-E7
Cable bend: IEC 60794-1-2-E11A
Attenuation Coefficient: ITU-T G. 652
Structural Test: IEC-60793-1-20
Environmental Performance
Temperature Cycling: IEC 60794-1-2-F1
Water Penetration: IEC 60794-1-2-F5B
Filing Compound Flow: IEC 60794-1-E14
Technical Parameters
Fiber Count | 2-8 | 10-12 | 14-24 | |
Diameter of Strengthen member (FRP) | 2x0.5mm | |||
Reinforcing material | F i ber glass yarn/Kevlar yarn | |||
Diameter of Loose tube(mm) | 2.4 | 2.4 | 2.8 | |
Diameter of Cable(mm) | 5.8 | 5.8 | 6.3 | |
Gross weight(Kg/Km) | 28 | 28 | 36 | |
Min. bending radius | Static 10xD Dynamic 20xD | |||
Max. tensile force, N | Short term/ Long term 1000N/300N | |||
Max Crush Resistance(N/100mm) | Short term/ Long term 500N/200N | |||
Allowable T emperatures | operation | -40°C - +60°C | ||
storage | -50°C - +70°C | |||
install. | -20°C - +50°C |
Features
Embedded strength member provide desirable tensile strength.
Compact, easy to install.
UV and moisture-resistant design
Applications
Installed in duct, direct burial.
FTTx.
Optical Charateristics
Fiber Type | G.652 | G.655 | 50/125^m | 62.5/125^m | |
Attenuation (+20X) | 850 nm |
|
| <3.0 dB/km | <3.3 dB/km |
1300 nm |
|
| <1.0 dB/km | <1.0 dB/km | |
1310 nm | <0.36 dB/km | <0.40 dB/km |
|
| |
1550 nm | <0.22 dB/km | <0.23 dB/km |
|
| |
Bandwidth | 850 nm |
|
| >500 MHz-km | >200 Mhz-km |
1300 nm |
|
| >500 MHz-km | >500 Mhz-km | |
Numerical Aperture |
|
| 0.200±0.015 NA | 0.275±0.015 NA | |
Cable Cut-off Wavelength cc | <1260 nm | <1450 nm |
|
|
Structure and Technical Specifications GYXY
Fiber Count | Nominal Diameter (mm) | Nominal Weight (kg/km) | Allowable Tensile Load (N) | Allowable Crush Resistance | ||
Short Term | Long Term | Short Term | Long Term | |||
2~12 | 6.2 | 52 | 1000 | 400 | 1000 | 1000 |
14~24 | 7.0 | 64 | 1200 | 500 | 1000 | 1000 |
Note : This datasheet can only be a reference, but not a supplement to the contract. Please contact our sales people for more detailed information.