Blue Jay GYID series Electric Vehicle DC Insulation Monitoring device is used for real-time monitoring of the insulation resistance between the high voltage components (0~1000Vdc) and the chassis (earth) of the power battery pack (pure electric or hybrid) power supply system. The measurement technology used in this product can monitor the insulation faults on the DC side, the AC side, and the motor side; The ground fault detection DC system can simultaneously monitor the positive and negative asymmetric insulation faults and symmetrical insulation faults; it can monitor the internal insulation faults of the battery pack and locate the fault point; It can monitor in the case of short circuit on the high-voltage DC side; in the case of high-intensity interference, such as acceleration, deceleration, and energy recovery, it can also reliably monitor insulation resistance.
- Monitor the insulation state of all internal Class Voltage(high voltage side)components of the 0~1000VDC DC floating system(IT system).
- Measuring battery pack DC voltage
- Continuous measurement of insulation resistance of 0~50MΩ
- Communicate using the CAN bus interface
- Monitor the positive and negative insulation resistance separately
- Monitor the total insulation resistance and report the location of the battery insulation fault
- Automatically adapt to existing system capacitor CY(CY≤4uF)
- Operatingtemperature-40~+105
- High internal resistance up to 10MQ
- injected sianalamplitude±15V
- Fault responsetime≤5s
- High and low voltage side isolation voltage 3500VDC/2500 VAC(rms)
- With CAN Bootloader, upgrade program by CAN

Accuracy | 1% |
Measurement range | 0-1000VDC |
0-750VAC | |
Power supply | 9-36VDC |
Input power | ≤ 2W |
Insulation resistance | 0 ~ 50 MΩ (Default is 50 MΩ when over 50 MΩ) |
Insulation accuracy | ±12 kΩ (@ 0~100 kΩ, CY≤ 2μF) |
±10 % (@100 kΩ~1 MΩ, CY≤ 2μF) | |
±10 % (@1MΩ~50MΩ, CY≤ 2μF) | |
Response time | 4s (@RISO≥ 500 kΩ, CY =0μF) |
5s (@RISO<500 kΩ, CY =0μF) | |
8s (@RISO=1MΩ, CY =1μF) | |
12s (@RISO=1MΩ, CY =2μF) | |
High voltage input resistance | Positive 5 MΩ,Negative 1 MΩ to ground (@Internal high voltage relay closed) |
Positive& negative poles to ground over 500 MΩ (@Internal high voltage open) | |
Pulse signal amplitude | ±15 V |
Pulse signal frequency | Adaptive |
Isolation withstand voltage | 3500VDC, 2500VAC (RMS) |
Operating temperature | -40 ~+85 |
Storage temperature | -40 ~+85 |
IP protection | IP 55 |
Weight | 0.5kg (Aluminum package) |
1. Electric Vehicle (EV) power battery high-voltage systems
2. Hybrid Electric Vehicle (HEV) high-voltage systems
3. Hydrogen Fuel Cell Electric Vehicle (FCEV) high-voltage systems
4. Energy Storage Systems (ESS)
5. Other DC floating systems
6. AC floating systems
7. Various other ground insulation monitoring applications