HD-8000A Biphasic Defibrillator Manual External Asynchronous Defibrillation Portable

Price $1250.00 Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 326 people viewed
Quantity
+-
 

Nanjing Foinoe Co., Ltd.

VIP   Audited Supplier 18 years
Profile Certified by SGS/BV
HD-8000A
Metal, Plastic, Steel
Travel, Hospital, Vehicle, Factory, Office
Defibrillator
Medium
CE, FDA, ISO13485
Medium
Simple
Customized
Everyone
Reusable
Manual Synchronized Asynchronized
100V-240V 50Hz/60Hz
Foinoe
Wooden Carton
Package Size: 54*45*37cm
China
Product Description
Product Description

 

HD-8000A Biphasic Defibrillator Automated External AED Portable
Technical Specifications
Defibrillator 
Defibrillator TypeManual, Synchronized, Asynchronized
Charging TimeMaximum 10 Seconds To 360 Joules

DEFIBRILLATOR
(1)Defibrillator Type:Manual,Synchronized,Asynchronized
  1. Energy accuracy:<+1%
  2. Energy selection:0.3.5.7.10.20.30.50.100.200.300.360joules(nominal at a resistance of 50)
  3. Charging Time:Maximum 10 Seconds To 360 Joules
  4. Standard adult/pediatric paddles:reusable external adult paddles (pediatric paddles integrated)

Power requirements
  1. AC Power supply :100v-240v,50hz/60hz
  2. Vehicle voltage(option):dc 12v

Internal battery backup
  1. battery type: rechargeable lead-acid battery(12v 2.0ah *2)
(2)Charing time:time-minimum of 4 hours for full charging
(3)battery charging:during ac power supply operation of the device
(4)charing/low battery indication:red led
(5)battery capacity:100% of the battery will provide 120-min monitoring;and 35discharges at 360 joules

Display
Lcd dimensions 7-inch
Type:high resolution true-color graphic
Resolution:480*234

HD-8000C Defi-monitor
HD-9000C Defi-Monitor

Physical characteristics
Main unit: portable
Dimensions:L320*W205*H410
Weight:9.8kg

ECG
ECG lead: I.II. III AVR AVL AVF V1-V6
S-T segment analysis: -2.0-2.0mv
Arrhythmia analysis: yes
Protection: With stand 4000VAC/50HZ voltage in
isolation and work against electrosurgical knife and
defibrillation

Respiration
Measurement method.:Thoracic impedance
NIBP
Working mode: Manual/Automatic/stat(5 minutes)
Method Automatic oscillation
Cuff type standard Adult, optional Pediatric/Neonatal

Temperature
Measurement range 20-45ºC
Resolution 0.1ºC

Pulse Oximetry(SPO2)
Display: spo2 value, pulse histogram, waveform, Pulse
Range: 0-99%for adult, pediatric and neonatal patients
Probe: standard adult finger clip
optional pediatric Y-type clip and neonatal wrap
Pulse range
Pulse range: 0-255bpm
Standard parameter &configuration
ECG/ RESP/SPO2/TEMP/PR/NIBP/DEFIBRILLATOR
Optional parameter
Recorder Liion battery (11. 1V 4AH X2)

 
Detailed Photos

 


Specifications

 


Other Model

 

HD-8000C 

HD-8000D

Defi 5S
HD-9000A

Customer Photo

 


Send your message to us and click "Send" now 
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA