Using ultrasonic transit time techniques, the is controlled by a micro-processor system which
contains a wide range of data that enables it to be used with pipes with an outside diameter ranging from 15mm up to 6000mm (depending on model) and constructed of almost any material. The instrument will also operate over a wide range of fluid temperatures.

High Accuracy measuring
Linearity: better than 0.5%, Repeatability: better than 0.2%, Accuracy: better than ±1%
Small size, Light weight
Dimensions: 200×93×33mm; Weight:390g
Non-intrusive measuring
Non-intrusive, clamp-on transducer, no pressure drop, no pipe disturbance.
Wide measuring range
Several types transducer for selection, measuring pipe size from DN15mm to DN6000mm
Large LCD display
Display instantaneous flow, accumulated flow (positive, negative and net), velocity, working status etc.
Built-in data logger
Built-in 24K data logger, store over 2000 lines measuring data
Specifications:Items | Performance and Parameter | |
Main Unit | Principle | transit-time ultrasonic flowmeter |
Accuracy | Accuracy :over 1%-2%; Repeatability: over 0.2% | |
Display | 4 line x 16 character LCD with backlight | |
Dimension | 200*93*33cm: 390g | |
Operation | Support 16 key light touch keyboard and the Simulation keyboard software | |
Data interface | Insulate RS232 serial interface, upgrade the flew meter software by computer, support the MODBUS, etc. | |
Signal Output | 1 way OCT output | |
Special Cable | Twisted-pair cable, ;Select the RS232 communication.; Generally, the standard is 5m*2, optional 10m*2 | |
Pipe Condition | Pipe Material | Steel, Stainless steel, Cast iron, Copper, Cement pipe, PVC, Aluminum, Glass steel product, liner is allowed. |
Pipe Diameter | DN 15---6000mm | |
Straight length pipe | Transducer installation should be satisfied: upstream10D, downstream 5D, 30D from the pump. | |
Measuring Medium | Type of Liquid | Water ; Ultra-pure liquids; Solvents and other liquids |
Temperature | Standard Transducer: -30--90ºC; High-temperature transducer: -40--160ºC | |
Turbidity | under 10000ppm and less bubble | |
Flow rate | 0--±10m/s | |
Flow Direction | Measuring two (plus-minis) direction of flow rate | |
Working Environment | Temperature | Main Unit: -20--60ºC |
Flow transducer: -40--160ºC; Temperature transducer: according to the customer's demands. | ||
Humidity | Main Unit: 85% RH | |
Power Supply | AC 110V-240V |
Optional Transducer:


Wide Application:
- Water, including hot water, chilled water, city water, sea water and more.
- Sewage and drainage water with small particle quantity
- Oil, including crude oil, lubricating oil, diesel oil, fuel oil, etc.
- Chemicals, including alcohol, acids and more.
- Solvents
- Beverage and food processors
- HVAC hot and cool water, water/glycol solutions
- Water and waste treatment
- Power plants (nuclear, thermal & hydropower) heat energy boiler feed water
- Energy consumption supervision and water conservation management
- Metallurgy and mining applications (e.g., acid recovery)
Package and Delivery:

CERTIFICATES: ATEX/CE/ISO9001/SIL3/SGS

PLEASE CONTACT ME FOR PRICE, THANKS