UIB-CMF 1
1year
1year
±0.2%~±0.15%, ±0.2-0.5%
Water, Wastewater, Diesel Fuel, Fuel Oil, Nature Gas, Corrosive Liquid/Gas
DN1.5~DN200
Tube/Flange
Industrial Production
Coriolis Mass Flow Meter
Liquid and Gas
Physical Properties Fiber Optic Sensor
Closed Pipeline
JIS, DIN, ANS, GB, CE, ISO
Liquid, Air, Solid Flow
4-20mA, Pulse, RS485,
Transient Flow+Accumulated Flow + Density + Temper
Two-Phase Flow, Three-Phase Flow
Frequency State Modulation
Digital Type
Integration
Functional
0.2%
IP65
All Industrial
U-ideal
Wooden Case or Carton
sgs, iso
Tianjin, China
90261000
Product Description
Introduction
Coriolis Mass Flow Meters' measuring principle is based on the controlled generation of Coriolis forces. The measurement would not be affected by the pressure, temperature, viscosity, density, etc. And the compensation calculation is not required. The structure contains two parts: Sensor & Transmitter. The Coriolis Mass Flow Meters are designed and manufactured based on the national standard of safe explosion proof. The Explosion- proof standard is EX d ib II C T6


UICMF series mass flow meter sensor consists of measurement tube, driving
device, position detector, support structure, the temperature sensor, housing, etc.
1.Supporting structure: the measuring tube fixed on the supporting structure as the vibrating axis.
2.The measuring tube (Vibrating tube): consist of two parallel tubes.
3.Position detector: used for the measurement of measuring tube distortion.
4.Drive device: generate electromagnetic force to drive measuring tube to make it vibrate close to resonance frequency.
5.Housing: Protect the measuring tube, driving unit and detector.
device, position detector, support structure, the temperature sensor, housing, etc.
1.Supporting structure: the measuring tube fixed on the supporting structure as the vibrating axis.
2.The measuring tube (Vibrating tube): consist of two parallel tubes.
3.Position detector: used for the measurement of measuring tube distortion.
4.Drive device: generate electromagnetic force to drive measuring tube to make it vibrate close to resonance frequency.
5.Housing: Protect the measuring tube, driving unit and detector.
Size | A | B | C | D | E | NW(only sensor) |
mm | mm | mm | mm | mm | kg | |
20 | 540 | 478 | 468 | 108 | 245 | 17 |
25 | 540 | 492 | 468 | 108 | 245 | 17.5 |
32 | 544 | 517 | 468 | 108 | 245 | 24 |
40 | 600 | 635 | 500 | 140 | 267 | 32 |
50 | 606 | 653 | 500 | 140 | 267 | 36 |
80 | 866 | 857 | 779 | 219 | 316 | 87.5 |
100 | 950 | 977 | 833 | 273 | 340 | 165 |



Aside from the size of the meter, the type of data provided depends on the complexity of the meter though most meters supply the same data but have different methods for setting the meter. Some of the settings of a Coriolis flow meter include:
- Flow direction
- Maximum mass flow - set up at pounds per hour
- Volume flow - measured in gallons per minute
- Density - measured by the meter in kilograms or pounds per hour
- Temperature - maximum load temperature
- Fraction Totalizer - totalizer values can be in volume flow, mass flow,
Specification | DN (mm) | Flow range(kg/h) | Zero Stability, kg/h | Rated Pressure (MPa) | NW (kg) | GW (kg) | ||
0.2% | 0.15% | 0.1% | ||||||
UICMF-003 | 3 | 0~96 | 0.018 | 0.012 | 0.012 | 40 | 8 | 19 |
UICMF-006 | 6 | 0~540 | 0.099 | 0.066 | 0.066 | 20 | 12 | 22 |
UICMF-008 | 8 | 0~960 | 0.18 | 0.12 | 0.12 | 20 | 12 | 23 |
UICMF-010 | 10 | 0~ 1500 | 0.27 | 0.18 | 0.18 | 20 | 11 | 24 |
UICMF-015 | 15 | 0~3000 | 0.63 | 0.42 | 0.42 | 20 | 12 | 25 |
UICMF-020 | 20 | 0~6000 | 1.17 | 0.78 | 0.78 | 16 | 20 | 34 |
UICMF-025 | 25 | 0~9600 | 2.025 | 1.35 | 1.35 | 16 | 21 | 35 |
UICMF-032 | 32 | 0~ 18 000 | 3.6 | 2.4 | 2.4 | 16 | 27 | 45 |
UICMF-040 | 40 | 0~30 000 | 5.4 | 3.6 | 3.6 | 12 | 35 | 55 |
UICMF-050 | 50 | 0~48 000 | 9 | 6 | 6 | 12 | 40 | 60 |
UICMF-080 | 80 | 0~ 120 000 | 24 | 16 | 16 | 8 | 90 | 150 |
UICMF-100 | 100 | 0~ 192 000 | 40.5 | 27 | 27 | 8 | 170 | 245 |
UICMF-150 | 150 | 0~360 000 | 90 | 60 | 60 | 6 | 255 | 350 |
Coriolis flowmeter is a mass flowmeter to directly and continuously measure the "mass", the only characteristic of fluid that is not affected by the change in temperature, pressure, viscosity, and density of it. Based on a unique principle utilizing Coriolis force, wide range of mass flowrate based system can be configured by detecting the mass flowrate in high accuracy and sensitivity and converting it to analog or frequency output. In addition to general liquids, flowrate of foods, chemicals, slurry, high-density gas, etc. can be measured. A major feature of the Coriolis flowmeter is a complex sensor that can measure temperature and density simultaneously with flowrate.