APM-96Q three-phase multifunction power meter is a Mid-range electrical panel power meter. It is the ideal choice for monitoring and measuring 3P4W or 3P3W power systems.
This three-phase power meter can measure all of the power parameters in the power grid:
Current, Voltage, Frequency, Active power, | Reactive power, Apparent power, Energy (Active/Reactive), Power factor, | Current harmonics 2~15 times, Voltage harmonics 2~15 times, Voltage and current THD%, Multi-tariff record(TOU) |
With optional expansion modules, it can also transmit the parameter into 2*Relay output (2DO) and 4*Switch input (4DI), 1*Analog output (1AO). For transformers, generators, capacitor banks, and motors of the distributed detection, automatic control system, and online monitoring display.
It can replace the traditional analog or many digital measurement instruments (such as an ammeter, voltmeter, power meter, power factor meter, frequency meter, etc.) with the advantages of improving system reliability, making the on-site wiring convenient, and reducing system cost.
With a serial port, the BJ-194Y multifunction panel meter can connect with a PC; and use Modbus to set programming and read the data. Based on these power meters, you can simply set up a monitoring system with the IPC and central software. Optional RJ45 Ethernet port for MODBUS-TCP protocol.
- Class 0.5s for basic power parameter, according to IEC62053-22 standard
- Class 0.5s for active energy (kWh), Class 1.0s for reactive energy (kVarh),
- Panel mounting size: 96*96mm
- ITF technology: galvanic insulation protection for inputs and outputs
- Colorful TFT screen display with English characters
- Provides THD and 2-63th harmonic individual monitoring with bar graph display
- Records multi-tariff energy data
- Displays three-phase current and voltage waveforms
- Monitoring of Max demand, Grid unbalance, Voltage, and Current deviation.
- Voltage drop and flicker monitoring and recording
- 5 virtual alarms for event tracing
- Max 50 SOE records and waveform capture for fault tracing
- Optional 128MB memory for logging basic electrical parameters
- Optional 3 AO ports for electricity transmitter
- Optional 2 DO ports for remote control
- Optional 4 DI ports for data collection

ower Supply | AC / DC 85-265V, 45-65Hz DC 20-60V (Optional) Burned < 10VA |
Current Measurement | …/ 1A or …/5 A Burned < 0.1W |
Voltage Measurement | Direct measurement 18~277V ac (L-N) PT secondary …/100Vac Burned < 0.1W |
Frequency Measurement | 45~65Hz Resolution 0.01Hz |
Accuracy | U & I - 0.5S ; P &Q - 0.5S Frequency - 0.1S Active Energy - 0.5S class Reactive Energy - 1.0S class |
Communication Port | RS485 (2/3 wires half duplex) Modbus RTU mode |
Pulse Outputs | 1 channel Coupler relay |
Analog Outputs (Optional) | Max 3 channel Isolated 0 / 4 … 20 mA |
Alarms Outputs (Optional) | Max 2 channel DO & 4 channel DI 230 VAC 5 A |