HPS30-150
Support
5 Years
Active Inverter
Three
30-150kw
SAA, CE, ROHS, ISO9001, CCC
Atess
DC/AC Inverters
Solar Power
Full-Bridge Type
Sine Wave Inverter
Forced-Air
Triple
43~217A
352V-600V
355~1230kg
99.5%
Atess Hybrid Inverter
-25 °c~+55°c
360V-440V
Commercial
IP20
50/60Hz
CE&TUV
Touch Screen
RS485/Can
ATESS
Wooden Box Packaging
120X190X80cm
Anhui, China
8504409990
Product Description
High efficiency Atess HPS 30kw 50kw 100kw 120kw 150kw on/off Grid Hybrid Solar Inverter







Model | HPS30 | HPS50 | HPS100 | HPS120 | HPS150 |
AC(On Grid/Grid Connect) | |||||
Apparent Power | 33KVA | 55KVA | 110KVA | 132KVA | 165KVA |
Rated Power | 30KW | 50KW | 100KW | 120KW | 150KW |
Rated Voltage | 400V | 400V | 400V | 400V | 400V |
Rated Current | 43A | 72A | 144A | 173A | 217A |
Voltage Range | 360V~440V | 360V~440V | 360V~440V | 360V~440V | 360V~440V |
Rated Frequency | 50HZ(45-55) 60HZ(55-65) | 50HZ(45-55) 60HZ(55-65) | 50HZ(45-55) 60HZ(55-65) | 50HZ(45-55) 60HZ(55-65) | 50HZ(45-55) 60HZ(55-65) |
THDI | <3% | <3% | <3% | <3% | <3% |
PF | 0.8lagging-0.8leading | 0.8lagging-0.8leading | 0.8lagging-0.8leading | 0.8lagging-0.8leading | 0.8lagging-0.8leading |
AC Connection | 3L/N/PE | 3L/N/PE | 3L/N/PE | 3L/N/PE | 3L/N/PE |
AC Input | 60KVA | 100KVA | 200KVA | 240KVA | 240KVA |
AC(Off Grid) | |||||
Apparent Power | 33KVA | 55KVA | 110KVA | 132KVA | 165KVA |
Rated Power | 30KW | 50KW | 100KW | 120KW | 150KW |
Rated Voltage | 400V | 400V | 400V | 400V | 400V |
Rated Current | 43A | 72A | 144A | 173A | 217A |
THDU | ≤2% linear | ≤2% linear | ≤2% linear | ≤2% linear | ≤2% linear |
Rated Frequency | 50/60HZ | 50/60HZ | 50/60HZ | 50/60HZ | 50/60HZ |
Overload Capability | 110%-10mins 120%-1mins | 110%-10mins 120%-1mins | 110%-10mins 120%-1mins | 110%-10mins 120%-1mins | 110%-10mins 120%-1mins |
DC(Battery&PV) | |||||
Max Input PV Voltage | 1000VDC | 1000VDC | 1000VDC | 1000VDC | 1000VDC |
Max PV Power | 45kWp | 75kWp | 150kWp | 180kWp | 225kWp |
PV Mppt Voltage | 480V~800V | 480V~800V | 480V~800V | 480V~800V | 480V~800V |
Battery Voltage Range at Max Charge Power | 450V-600V | 500V~600V | 500V~600V | 517V~600V | 500V~600V |
Battery Voltage Range | 352V~600V | 352V~600V | 352V~600V | 352V~600V | 352V~600V |
Max Charge Power | 45KW | 75KW | 150KW | 180KW | 225KW |
Max Discharge Power | 33KW | 55KW | 110KW | 132KW | 165KW |
Max Charge Current | 100A | 150A | 300A | 350A | 450A |
Max Discharge Current | 93A | 156A | 313A | 374A | 467A |
General Information | |||||
Protection Degree | IP20 | ||||
Noise Emission | <65dB(A)@1m | ||||
Operation Temp. | -25ºC ~ +55ºC | ||||
Cooling | Forced-air | ||||
Relative Humidity | 0-95% non condensing | ||||
Max. Altitude | 6000m(derate over 3000m) | ||||
Dimension W*H*D | 700*1660*600mm | 950*1860*750mm | 1200*1900*800mm | 1200*1900*800mm | 1200*1900*800mm |
Weight | 355kg | 610kg | 948kg | 1025kg | 1230kg |
Transformer | Build in | ||||
Transfer time | Automatic transfer between ON/OFF Grid≤10ms | ||||
Self consumption | Standby Consumption<30W | ||||
Communication | |||||
Display | Touch Screen | ||||
Communication | RS485/CAN | ||||
Certificate | CE , MEA , PEA , AS 4777.2,EN 61000-6-4:2007+A1:2011 , EN61000-6-2:2005 , EN62109-1:2010 , EN62109-2:2011 , EN 50549-1:2019 , IEC62109.1 , IEC62109.2, NRS 097-2-1:2017, G99, VDE-AR-N 4105:2018,DIN VDE V 0124-100:2020-06 | ||||
Mark: * Battery voltage is determined by the following equation: Vmin = 352 x Vn/V1 , VMax= (Vmpp - 100)*Vn/V2 , VMax<600VDC V1 is battery cell discharge cut-off voltage, V2 is battery cell boost charge voltage, Vn is battery cell nominal voltage. |

ATESS HPS bidirectional battery inverter is designed for energy storage system, it converts DC current generated by battery bank into AC current and feed it into the load/grid, also it can take power from solar inverter or grid to charge battery to ensure uninterrupted power supply to the load.

* Open station supports one-click installation and registration
* Problem support one-click dispatch and navigation
* Safe operation, traceable logs, etc
* Support full lifecycle data storage to ensure data security and reliability



