High-Frequency Field Intensity Meter Emf829)

Price $115.00 Compare
Min Order 2 Pieces
Shipping From Guangdong, China
Popularity 409 people viewed
Quantity
+-
 

Shenzhen Bestone Industrial Co. Ltd.

VIP   Audited Supplier 16 years
Profile Certified by SGS/BV
EMF829
During The Warranty Period, Free Repair
One Year
50MHz to 3.5 GHz
20mv/M to 108.0V/M
About 65dB
± 1.0dB(For1.93GHz)
± 3.0dB (50MHz~800MHz)
BESTONE
Carrying Case
CE, ROHS
China
Product Description
Product Description

This meter is designed as wide frequency to supervise high frequency transmission of range from 50MHz to 3.5GHz. It has the non-directional measurement feature and high sensitivity. It can be used to measure electromagnetic field intense of the transverse electromagnetic wave cell and Absorber rooms.

Feature:
* Metrical ways:digit display, measuring with three axes
* Characteristic of directivity : isotropic, three axes
* Metrical gear: one continuous gear
* Resolution displayed:  0.1mV/m,0.1uA/m,0.1uW/m²,mW/m²,uW/cm²
* Reaction time: about 1 second (the measurement value is from 0 to 90% )
* Refresh rate displayed: about 0.5 second
* Display format: LCD, 4 digits
* Alarm: buzzer
* Units: mV/m,V/m,uA/m,mA/m,uW/m²,mW/m²,uW/cm²
* Displayed value:  the instantaneous measurement value, the MAX measurement value, average measurement value and the maximum averaging value
* Warning function:  you can adjust the setting value and you also can open the function or close it.
* Correction factor(CAL):  it can be adjusted
* Manual memory and reading data content: 70 groups(only recall by meter)
* battery: 4 batteries of 1.5V
* Battery life: about 15 hours
* Power off automatically: 15 min
* The range of the operation temperature: from  0°C  to  +50°C
* The range of the operation humidity:  from 25% to 75%RH
* The range of the stored temperature: from -10°C to +60°C
* The range of the stored humidity: from 0% to 80%RH
* Size: 261cm(length)* 73cm(width)*38cm(height)
* Weight( include the batteries): about 220g
Product Parameters

Specification:

*  The following specification all adapt for the following conditions except for some special explanation:the meter locate the far-field region of the radiation source and the inductor aim at emissive source.
* ambient temperature:+23°C±3°C
* relative air humidity: 25% to 75%
* inductive mode: electric field(E)
* frequency range: 50MHz to3.5GHz
* measuring range: continuous (CW)signal(f>50MHz): 20mV/m to 108.0V/m;
                                       53uA/m to 286.4mA/m;
                                       1uW/m² to 30.93W/m²;
                                       0uW/cm² to 3.093mW/cm²
* dynamic range:  about 75dB
* absolute error(lower than 1V/m and 50MHz): ±1.0dB
* frequency response:   

Taking into account the sensor CAL factor:

± 3.0dB (50MHz~800MHz) ;

±2.0dB(800MHz ~2.9GHz) ;

± 3.0dB (2.9GHz~ 3.5GHz) ;


Isotropic windage: about ±1.0dB(f>50MHz)
overloading limit: 0.42mW/cm2(40V/m)
* temperature response: (0 to 50°C): ±0.2dB
Detailed Photos

 

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA