High Frequency Online UPS HP9116c Series (6~20kVA)

Price Negotiable Compare
Min Order 100 Pieces
Shipping From Guangdong, China
Popularity 430 people viewed
Quantity
+-
 

Shenzhen SORO Electronics Co., Ltd.

VIP   Audited Supplier 18 years
Profile Certified by SGS/BV
HP9116C 6-20KVA
Single Phase
On-line
Overvoltage
Communication
Lighting/Power
Standard Machine
Sine Wave Output UPS
Large Type
Centralized Model
Emerson
0.7 or 0.8 Optional
115~300VAC
176~276VAC
50/60Hz
110%~150% for 30sec, >150% for 200ms
105%~130% for 10min, >130% for 1min
5hrs to 90% of Capacity
0ms
SOROTEC
Standard Exported Carton and Pallets
CE; RoHS; ISO9001
China
8504402000
Product Description
Hihg Frequency Online UPS HP9116C series (6~20kVA)

Key Features:
1)Large Blue Back Light LCD for Detailed Real-Time UPS Status Display

2)High frequency UPS and double conversion on-line technology

3)Fully digitized microprocessor control

4)Microprocessor control guarantees high reliability

5)Comprehensive Self-Protection Design

6)Audible Alarm Mute

7)Cold Start Funcition

8)Auto Self-Testing System whileTurning on UPS

9)Wide Input Voltage Range

10)Automatic start & inspect

12)Zero transfer time

13)Advanced battery management

14)Automatic battery charge in UPS off mode

15)Lightning and surge protection

16)Short circuit and overload protection

17)Fan speed auto control when loads varies

18)Optional extension battery pack

19)Maintenance Bypass Switch For 6-20K

20)N+X Parallel Redundancy and Capaacity Expansion For 6-20K


Applications:
Servers, Data-center, critical network devices, Sensitive electronic equipment, Telecom

Tendy&Elegant LCD Design for real-time UPS systm information:



Back Panel Description:






Technical Specifications of High Frequency Online UPS HP9116C 6-10K (1pH in/1pH out):
ModelHP9116C 6-10KVA
6KT6KT-XL10KT10KT-XL
Rated Power6KVA/4800W10KVA/8000W
Rated Voltage220/230/240VAC
Rated Frequency50/60 Hz
Input
VoltageRange176~279VAC (± 3VAC)
FrequencyRange50HZ: (46~54HZ); 60HZ: (56HZ~64HZ)
Power Factor0.98
Output
Voltage Regulation220/230/240X(1± 2%)VAC
Frequency Regulation50/60 Hz± 0.05Hz
Power factor0.7/0.8 (Optional) Standard 0.7
Voltage distortionLinear load< 3%      Non-linear load< 6%
Overload
Capability
110%~150% for 30s change to bypass model, Recover after load normal
Current Crest Ratio3; 1
Transfer time0ms (AC mode→ Battery mode)
Battery
DC Voltage240VDC
Recharge Time7hrs to 90% of capacity after full load discharge
Recharge Current2A4.2A2A4.2A
Display
LCDDisplay input/output Voltage, Frequency, Battery voltage, Battery capacity, Loading rate.
Communication
InterfaceSmart RS232, SNMP card (optional), USB (optional)
Environment
Operation Temperature0~40 º C
Humidity0~95%non-condensing
Storage Temperature-25 º C~55 º C
Sea level elevation< 1500m
Noise Level(1m)< 55dB
Physical Characteristic
Wright(KG)N. W.8135.58436
G. W.8939.59142
Dimension(D x W x H)mm570X260 X717
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA