High Frequency Power Transmission Voltage Step Toroidal Split Core Current Distribution Electric Cast Epoxy Resin Insulation Oil Immersed Transformer Price

Price $3000.00 Compare
Min Order 1 Piece
Shipping From Jiangsu, China
Popularity 249 people viewed
Quantity
+-
 

Jiangsu Liyang Electric Appliances Manufacturing Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
Power, Electronic, Instrument, Lighting, Rectifier, Audio
Single
Core-type Transformer
Dry-type Transformer
Separated Winding Transformer
ISO9001-2000, ISO9001, CCC
Single-phase Transformer, Rectifier Transformer, Combined Transformer, Power Transformer, Distribution Transformer
Power Frequency
OD
ABB
12 Months
Avaliable
Avaliable
One
liyang electric
Wooden Case
as per design
China
8504330000
Product Description
 

Product Description

1.Three leg core:Made of grain oriendted low loss electrolami nations insulated on both sides.
2.Resilient spacers:To insulate core and windings from mechanical vibrations,resulting in low noise emissions.
3.HV winding:Consisting of vacuum potted single foil type aluminum or copper coils.
4.LV winding:Made of copper or aluminum strip.Turns firmly glued together by means of insulating sheet wrapper material.
5.Insulation:Mixture of epoxy resin and quatrz powder.Makes the transformer maintenance free,moistureproof,tropicalized,flame resistant and self extinguishing.
6.Clamping frame and truck:Rollers can be swung around for lengthways or sideways travel.
7.LV terminals:
Normal arrangement:top,rear.
Special version:Bottom,available on request at extra charge.
8.HV terminals:Variable arrangerments,for optimal station design.HV tapping links on low voltage side for adjust ment to system conditions,reconnectable in deenergized state.
 
 
 
Three Phase Dry Type Transformer Core UL Power Transmission Transformers Voltage Step Down up Distribution Electric Cast Epoxy Resin Insulation Dry Type Transformer Price

The core is beveled and stepped for maximum performance and minimal bulk. After the magnetic steel is produced by the cutting machine, it is continuously cut into specific lengths by the automatic stacking machine, and then automatically stacked. The correct size is ensured during the entire stacking and assembly process to ensure the high quality of the product.

Dry Type Distribution Transformer Winding

UL Power Transmission Transformers Voltage Step Down up Distribution Electric Cast Epoxy Resin Insulation Dry Type Transformer Price
The low voltage winding adopts the whole section of copper foil, which is wound on the special low-voltage foil winding machine with the F-grade insulation. The foil coil solves the outstanding problems such as low voltage, high current coil winding, high short-circuit stress, unbalanced ampere turns, poor heat dissipation effect, windingspiral angle, unstable manual welding quality and so on. At the same tim-e, the winding ends of our company aresealed with resin, cured and formed, moisture-proof and antifouling. The lead copper bar is automatically welded byargon arc welding.

Dry Type Power Transformer Accessories

All the accessories you need to customize our products to your needs.
The casing is made from bolts on a steel plate with removable panels for attachment and tape. Depending on the application and your requirements, the surface treatment can be galvanized, painted. The design is optimized to ensure the required cooling of the transformer at all levels of protection. The enclosure can be shipped assembled on the transformer or flat packed for on-site assembly.
Other Accessories
cooling fan.
Temperature monitoring unit (thermal control system)

Product Feature

1. Low loss, low noise, low partial discharge.
2. Strong anti-short circuit capability and high anti-lightning impact level.
3. Excellent moisture resistance for operation at 100% relative humidity.
4. Strong overload capability for long-term operation at 150% loading. 

Temperature control device:

The transformer adopts the BWDK series signal thermometer. The temperature measuring element is embedded in the upper half of the low-voltage coil, which can automatically detect and display the respective working temperature of the phase coil, and has the function of over temperature alarm and trip.

More Product Parameters

SCB10 10kV Epoxy-resin Insulation Dry-type Transformer 
Rated Capacity(kVA)Voltage CombinedVector-groupNo-load Loss(W)75ºC
Load Loss(W)
No-load current(%)Short-circuit Impendance(%)
High voltage(KV)Tapping RangesLow voltage(KV)
306

6.3

6.6

10

10.5

11
±5%
±2×2.5%
0.4Dyn11

Yyn0
1907102.44
5027010002.4
8037013801.8
10040015701.8
12547018501.6
16054021301.6
20062025301.4
25072027601.4
31588034701.2
40098029901.2
500116048801.2
630134058801.0
630130059601.06
800152069601.0
1000177081301.0
1250209096901.0
16002450117301.0
20006050144500.8
25003600171700.8
16002450129601.08
20003050159600.8
25003600188900.8

SCB1110kV Epoxy-resin Insulation Dry-type Transformer 
Rated Capacity(kVA)Voltage CombinedVector-groupNo-load Loss(W)75ºC
Load Loss(W)
Short-circuit Impendance(%)Size(mm)Track gauge(mm)
High voltage(KV)Tapping RangesLow voltage(KV)
306

10

10.5

11
±5%0.4Dyn11

Yyn0
1805604800x660x940400x400
50260730830x690x990400x400
803201120860x690x1020400x400
1003501370900x720x1060550x550
1254301620940x740x1080550x550
16048019001220x770x1100550x550
20054021001240x780x1170550x550
25065025601390x800x1200550x550
31576030101410x820x1230550x550
40078036901500x860x1270660x660
50084043001520x870x1520660x660
6301040516061600x890x1410660x660
800124062901660x950x1460820x820
1000143073801760x970x1500820x820
1250150088301800x1090x1620820x820
16001710105801870x1100x1700820x820
20002200128101980x1180x18001070x1070
25002650150802090x1260x19301070x1070
SCB13 10kV Epoxy-resin Insulation Dry-type Transformer
Rated Capacity(kVA)Voltage CombinedVector-groupNo-load Loss(W)Load Loss under Different Insulation and Heat Resistance LevelsNo-load current(%)Short-circuit Impendance(%)
High voltage(KV)Tapping RangesLow voltage(KV)B(100ºC)P(120ºC)H(145ºC)
306

6.3

6.6

10

10.5

11
±5%
±2×2.5%
0.4Dyn11

Yyn0
1506707107602.44.0
50215940100010702.4
802951290138014801.8
1003201480157016901.8
1253751740185019801.6
1604302000213022801.6
2004952370253027101.4
2505752590276029601.4
3157053270347037301.2
4007853750399042801.2
5009304590488052301.2
63010705530588062901.0
63010405610596064001.06.0
80012156550696074601.0
100014157650813087601.0
1250167091009690103701.0
160019601105011730125801.0
200024401445014450155600.8
250028801717017170184500.8
SCB14 10kV Epoxy-resin Insulation Dry-type Transformer 
Rated Capacity(kVA)Voltage CombinedVector-groupNo-load Loss(W)Load Loss under Different Insulation and Heat Resistance LevelsNo-load current(%)Short-circuit Impendance(%)
High voltage(KV)Tapping RangesLow voltage(KV)B(100ºC)P(120ºC)H(145ºC)
306

6.3

6.6

10

10.5

11
±5%
±2×2.5%
0.4Dyn11

Yyn0
1306056406852.44.0
501858459009652.4
802501160124013301.8
1002701330141515201.8
1253201565166517801.6
1603651800191520501.6
2004202135227524401.4
2504902330248526651.4
3156002945312533551.2
4006653375359038501.2
5007904130439047051.2
6309104975529056601.0
6308855050536557601.06.0
80010355895626567151.0
100012056885731578851.0
125014208190872093351.0
16001665994510555113201.0
200020751224013005140050.8
250024501453515445166050.8
SCB18 10kV Epoxy-resin Insulation Dry-type Transformer 
Rated Capacity(kVA)Voltage CombinedVector-groupNo-load Loss(W)Load Loss under Different Insulation and Heat Resistance LevelsNo-load current(%)Short-circuit Impendance(%)
High voltage(KV)Tapping RangesLow voltage(KV)B(100ºC)P(120ºC)H(145ºC)
306

6.3

6.6

10

10.5

11
±5%
±2×2.5%
0.4Dyn11

Yyn0
1056056406852.44.0
501558459009652.4
802101160124013301.8
1002301330141515201.8
1252701565166517801.6
1603101800191520501.6
2003602135227524401.4
2504152330248526651.4
3155102945312533551.2
4005703375359038501.2
5006704130439047051.2
6307754975529056601.0
6307505050536557601.06.0
8008755895626567151.0
100010206885731578851.0
125012058190872093351.0
16001415994510555113201.0
200017601224013002140050.8
250020801453515445166050.8

 

 


Yb-11kv 15kv 24kv 33kv 400-2000kVA Export Type European Outdoor High Voltage Box Substation Prefabricated Cabin

Yb-11kv 15kv 24kv 33kv 400-2000kVA Export Type European Outdoor High Voltage Box Substation Prefabricated Cabin


Payment Term
Payment TermsT/TEXW30% T/T in advance, the balance to be paid before dispatch
FOB
CIF30% T/T in advance, the balance to be paid against the copy of B/L
CFR (C&F)
L/CIrrevocable L/C at sight could be accepted if amount above US $50,000.00
Delivery Time7 to 10 working days after receiving advanced payment
 

FAQ



Q:what's your major products?
A: oil immersed transformer, dry type transformer, Transformer Substation, High and Low Voltage Switchgear

Q: Can your product be customized?
A: Considering differences in voltage, frequency and other special transformer product in different countries and regions, our product can be customized according to your requirements.

Q: When can I get the price?
A:Usually we quote within 24 hours after we get your inquiry.

Q: What about lead or shipping time?
A: The lead time depends on the quantity you ordered, generally within 15 days upon receipt of advance payment.

Q: What is the price of shipping?
A: Depending upon the port of delivery, prices varies.

Q: Do you offer guarantee for the products?
A: Yes. We offer at least one years guarantee for all of our transformers.

Q: Your Advantage?
A: 15 years experience, Advanced production equipment, Stable quality, Fast delivery, Professional & good & Prompt service. Also some free parts can be provided for you.

Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA