Classification of flameproof electrical equipment
 
GasCategoryRankRepresentative gasesEquipment protection level
Coal mine gas environmentI-MethaneMa (very high)
         Mb ( High)

Explosive gas atmospheres other than coal mine gas

II
APropaneGa (very high)
           Gb ( High)
Gc (General)
BEthylene
CHydrogen
Temperature groupIgnition temperature of gas or vapor (°C)Maximum surface temperature of electrical equipment (°C)
T1T > 450450
T2450 ≥ T > 300300
T3300 ≥ T > 200200
T4200 ≥ T > 135135
T5135 ≥ T > 100100
T6100 ≥ T > 8585
 
Standards
Standard nameIECENGB
Rotating electrical machines Rating and operating behaviorIEC 60034-1EN 60034-1GB/T755
Process for determining losses and efficiency of rotating electrical machines by means of testingIEC 60034-2-1EN 60034-2-1GB/T1032
Protection types of rotating electrical machines based on overall construction(IP-Code) - IntroductionIEC 60034-5EN 60034-5GB/T 4942.1
Classification of the cooling processes (IC code)IEC 60034-6EN 60034-6GB/T 1993
Classification of the design types, the installation types and the terminal box location (IM-Code)IEC 60034-7EN 60034-7GB/T 997
Terminal markings and direction of rotationIEC 60034-8EN 60034-8GB 1971
Noise emission limit valuesIEC 60034-9EN 60034-9GB/T 10069.3
Starting performance of three-phase motors with squirrel-cage rotor, except for pole-changing motorsIEC 60034-12EN 60034-12-
Mechanical vibrations of certain machines with a shaft height of 56 mm and higher;measurement, evaluation and limit values of the vibrationIEC 60034-14EN 60034-14GB/T 10068
Efficiency classification of three-phase motors with squirrel-cage rotors, except for pole- changing motors (IE code)IEC 60034-30-1EN 60034-30GB18613
Balancing valueISO 1940--
IEC standard voltages IECIEC 60038--
Evaluation and classifications of electric insulation according to its thermal behaviorIEC 60085-GB/T 11021
Three-phase induction motors for general use with standardized dimensions and powersIEC 60072-1EN 50347GB/T 4772.1
Explosive atmosphere - Part 0: Equipment General requirementsIEC 60079-0EN 60079-0GB 3836.1
Explosive atmosphere - Part 1: Equipment protection through flameproof enclosure "d"IEC 60079-1EN 60079-1GB 3836.2
Explosive atmosphere - Part 7:Equipment protection through increased safety "e"IEC 60079-7EN 60079-7GB 3836.2
Electrical equipment for use in areas with inflammable dust - protection of the housingIEC 60079-31EN 60079-31-


 


Machine base number
Synchronous speed r/min
Number of poles
300015001000750600500429375
246810121416
Power(kW)
80M10.750.550.370.18










 













-












 














 
80M21.10.750.550.25
90S1.51.10.750.37
90L2.21.51.10.55
100L1 2.2 0.75
100L3-1.5 
100L2 3 1.1
112M442.21.5
132S15.5 - 
132S 5.532.2
132S27.5 - 
132M1  4 
132M 7.5-3
132M2  5.5 
160M111 -4
160M 117.5 
160M215 -5.5
160L18.515117.5
180M2218.5- 
180L 221511
200L130 18.5 
200L 30 15
200L237 22 
225S 37 18.515
225M4545302218.5
250M555537302218.5
280S75754537302218.5
280M90905545373022
315S110110755545373022
315M132132907555453730
315L11601601109075554537
315L185185-  -- 
315L220020013211090755545
355S1185185-   - 
355S  16013290757555
355S2200200-   - 
355M1220220185 110909075
355M  -160  - 
355M2250250200 13211011090
355L1280280220185160132  
355L   -  132110
355L2315315250200185160- 
355LX1355355280220200185160132
355LX2 375315250  - 


Experience unmatched performance with our dynamic 2-pole 50Hz motor, achieving a rapid 3000rpm for high-demand applications.
 

Model
PowerRated current IN (A)Rotational speednEfficiency η (%)Power factor cos ΦRated torque TNLockdown Current/Rated CurrentBlock torque/rated torqueMaximum torque/torque ratingNoise dB(A)Moment of inertiaWeight
kW380V415V1140Vr/min50%75%100%50%75%100%N.mIst / INTst/TNTM/TNAcoustic pressure LPAcoustic power LWkg  m2kg
YBX4-80M1-20.751.61.50.5289583.283.383.50.740.80.832.57.02.32.350620.001230
YBX4-80M2-21.12.42.20.8288284.985.585.20.740.80.833.67.02.32.350620.001435
YBX4-90S-21.53.12.81.0291086.287.186.50.750.820.854.97.02.32.355670.001646
YBX4-90L-22.24.44.01.5291487.788.488.00.760.830.867.28.02.32.355670.001863
YBX4-100L-235.95.42.0290588.889.789.10.790.840.879.97.02.32.362740.005869
YBX4-112M-247.77.02.6292689.790.690.00.790.860.8813.18.52.32.365770.007670
YBX4-132S1-25.510.49.63.5293690.691.290.90.790.860.8817.98.02.22.367790.016107
YBX4-132S2-27.514.012.84.7292891.492.391.70.80.860.8824.58.02.22.367790.02130
YBX4-160M1-21120.318.66.8294592.392.992.60.790.860.8835.77.02.22.368810.055179
YBX4-160M2-21527.425.19.1294592.993.593.30.790.860.8948.68.02.22.368810.059214
YBX4-160L-218.533.730.911.2295493.494.193.70.810.870.8959.88.02.22.368810.069277
YBX4-180M-222403713296493.794.394.00.810.870.8970.97.02.22.370830.098364
YBX4-200L1-230545018297494.194.394.50.820.870.88968.02.22.371840.20456
YBX4-200L2-237676122297394.294.794.80.820.860.891199.02.22.371840.23490
YBX4-225M-245817427297894.694.995.00.830.870.891448.02.22.373860.41537
YBX4-250M-255999033298094.995.395.30.830.870.891767.02.22.375890.48811
YBX4-280S-27513412345298195.395.695.60.830.880.892407.02.02.377910.891302
YBX4-280M-29016014753298095.595.895.80.840.880.892887.02.02.377911.081281
YBX4-315S-211019317764298095.796.096.00.840.880.893537.01.92.278921.761544
YBX4-315M-213223221277298095.996.296.20.840.880.894237.51.92.278921.881681
YBX4-315L1-216027525292298196.096.396.30.850.880.895137.51.92.278922.0772049
YBX4-315L-2185325298108298396.196.496.40.850.880.895927.51.92.278922.352188
YBX4-315L2-2200340311113298196.296.596.50.850.880.896417.01.92.278922.771806
YBX4-355S1-2185315288105298996.296.596.40.870.890.895917.01.92.2851003.462770
YBX4-355S2-2200347318116298896.296.596.50.880.890.896397.01.92.2851004.382217
YBX4-355M1-2220380348127299096.296.596.50.880.890.897037.01.82.2891044.382739
YBX4-355M2-2250435398145298896.296.596.50.880.890.907997.01.82.2891044.962380
YBX4-355L1-2280485444162298796.296.596.50.880.890.908957.01.82.2891044.972485
YBX4-355L2-2315541495180298996.296.596.50.880.890.9010067.01.82.2891045.952685
YBX4-355LX1-2355607556202298896.296.596.50.880.890.9011348.61.82.2891046.72500

The 4-pole 50Hz motor delivers a robust 1500rpm, perfectly balancing efficiency and power for diverse industrial uses.
 

Model
PowerRated current IN (A)Rotational speednEfficiency η (%)Power factor cos ΦRated torque TNLockdown Current/Rated CurrentBlock torque/rated torqueMaximum torque/torque ratingNoise dB(A)Moment of inertiaWeight
kW380V415V1140Vr/min50%75%100%50%75%100%N.mIst / INTst/TNTM/TNAcoustic pressure LPAcoustic power LWkg  m2kg
YBX4-80M1-40.551.31.20.4145082.884.283.90.550.670.743.67.02.32.344560.002432
YBX4-80M2-40.751.81.60.6144784.586.185.70.550.670.745.07.02.32.344560.00337
YBX4-90S-41.12.72.50.9145386.587.687.20.560.690.757.27.02.32.347590.003642
YBX4-90L-41.53.43.11.1145287.588.588.20.600.720.769.97.02.32.347590.004545
YBX4-100L1-42.24.94.51.6146389.289.789.50.620.730.7614.48.02.32.352640.01156
YBX4-100L2-436.96.32.3146390.190.790.40.630.740.7619.68.02.32.352640.01462
YBX4-112M-448.57.82.8146590.891.491.10.670.750.8126.19.02.32.353650.0274
YBX4-132S-45.511.210.33.7146991.692.191.90.670.770.8135.78.02.02.359710.035106
YBX4-132M-47.515.414.15.1147192.392.992.60.690.790.8348.79.02.02.359710.04119
YBX4-160M-41121.719.97.2147293.093.593.30.710.810.8371.48.02.02.360730.098169
YBX4-160L-41528.426.09.5147293.694.293.90.730.810.8497.38.02.02.360730.12207
YBX4-180M-418.53632.912.0148393.994.594.20.750.820.84119.28.02.02.363760.21278
YBX4-180L-4224238.514.0148294.294.594.50.750.820.84141.88.02.02.363760.23279
YBX4-200L-4305751.818.9148594.594.994.90.760.820.841937.02.02.363760.42408
YBX4-225S-4376862.322.7148994.795.295.20.770.820.852378.02.02.365780.49483
YBX4-225M-4458275.127.3148994.995.495.40.760.830.852898.02.02.365780.55585
YBX4-250M-45510293.434.0148995.295.795.70.780.840.863537.02.02.365790.89677
YBX4-280S-475138126.446.0148895.796.096.00.780.850.874818.02.02.366801.55821
YBX4-280M-490162148.554.1148995.896.196.10.790.860.875778.02.02.366801.86916
YBX4-315S-411019617965149096.096.396.30.790.860.897058.02.02.274883.571203
YBX4-315M-413223021177149296.196.496.40.800.870.898458.02.02.274884.201275
YBX4-315L1-416028526195148996.396.696.60.850.870.8910267.52.02.274884.661331
YBX4-315L-4185323296108148996.496.796.70.850.870.8911877.52.02.274884.831436
YBX4-315L2-4200348319116148996.496.796.70.860.880.8912837.52.02.274885.421547
YBX4-355S1-4185327299109149196.496.796.70.850.870.8911857.52.02.280956.881792
YBX4-355S2-4200349320116149196.496.796.70.850.870.8912817.52.02.280957.631859
YBX4-355M1-4220393360131149396.496.796.70.850.870.8914077.52.02.280958.171846
YBX4-355M2-4250435398145149296.496.796.70.860.880.8916007.52.02.280958.571993
YBX4-355L1-4280485444162149196.596.796.70.860.880.9017937.52.02.280958.562073
YBX4-355L2-4315318291106149296.596.796.70.860.880.9020177.52.02.280959.852208
YBX4-355LX1-4355615563205149296.596.796.70.860.880.9022727.52.02.28710210.602248
YBX4-355LX2-4375644590215149196.596.796.70.860.880.9024017.52.02.28710212.432499




Discover the smooth reliability of our 6-pole 50Hz motor, offering a steady 1000rpm for precision and control.
 

Model
PowerRated current IN (A)Rotational speednEfficiency η (%)Power factor cos ΦRated torque TNLockdown Current/Rated CurrentBlock torque/rated torqueMaximum torque/torque ratingNoise dB(A)Moment of inertiaWeight
kW380V415V1140Vr/min50%75%100%50%75%100%N.mIst / INTst/TNTM/TNAcoustic pressure LPAcoustic power LWkg  m2kg
YBX4-80M1-60.371.21.10.492677.278.078.00.490.610.683.86.01.92.042540.003128
YBX4-80M2-60.551.61.50.593880.380.980.90.510.630.645.66.01.92.142540.00433
YBX4-90S-60.751.81.60.695682.482.782.70.510.630.707.56.02.12.142570.005844
YBX4-90L-61.12.62.40.995484.184.584.50.520.640.7011.06.02.12.145570.007451
YBX4-100L-61.53.73.41.296684.986.085.90.560.660.7114.86.52.12.149610.01655
YBX4-112M-62.25.55.01.896986.787.587.40.560.660.7121.76.52.12.153650.02170
YBX4-132S-637.36.72.497388.288.688.60.570.660.7129.56.52.02.157690.02984
YBX4-132M1-649.48.63.197788.989.889.50.590.670.7239.17.52.02.157690.038101
YBX4-132M2-65.513.212.14.497789.790.890.50.590.670.7253.77.52.02.157690.054118
YBX4-160M-67.517.215.75.798090.891.691.30.610.720.7673.17.52.12.160730.13201
YBX4-160L-61123.821.87.998291.792.492.30.620.730.78107.07.52.12.160730.19243
YBX4-180L-61531291098692.392.992.90.680.760.80145.27.52.02.160730.27309
YBX4-200L1-618.538341398892.993.493.40.680.760.801797.52.12.160730.41372
YBX4-200L2-62246421598993.293.793.70.700.770.802137.52.12.160730.47413
YBX4-225M-63059542098893.794.294.20.710.780.812907.52.02.161740.97470
YBX4-250M-63770642399093.994.594.50.710.780.813577.52.12.162761.29578
YBX4-280S-64592843199393.994.894.80.720.780.814338.52.12.064782.71706
YBX4-280M-655108993699294.295.195.10.730.820.845298.52.12.064783.35810
YBX4-315S-6751411294798594.795.495.40.740.820.857278.02.02.069834.121152
YBX4-315M-6901681545698694.995.695.60.740.830.858728.02.02.069834.871233
YBX4-315L1-61102071906974194.995.895.80.740.830.8514188.02.02.069835.421309
YBX4-315L2-61322452258299295.196.096.00.740.830.8612718.02.02.069836.441486
YBX4-355S-61602922679799595.796.296.20.760.840.8615358.01.92.0708510.101882
YBX4-355M1-618533130311099395.896.396.30.760.840.8617798.01.92.0708511.262002
YBX4-355M2-620035932812099495.896.396.30.760.840.8619228.01.92.0708512.452094
YBX4-355L1-622039235913199495.996.496.40.820.850.8621148.01.92.0708513.182299
YBX4-355L2-625044941115099496.096.596.50.820.850.8624028.01.92.0708514.822363
YBX4-355LX1-628049645416599396.096.596.60.820.850.8626938.51.92.0769115.522416
YBX4-355LX2-631555951218699396.096.596.60.820.850.8630298.51.92.0769115.992459

Our 8-pole 50Hz motor sets the standard for dependable performance at 750rpm, ideal for low-speed, high-torque requirements.
 

Model
PowerRated current IN (A)Rotational speednEfficiency η (%)Power factor cos ΦRated torque TNLockdown Current/Rated CurrentBlock torque/rated torqueMaximum torque/torque ratingNoise dB(A)Moment of inertiaWeight
kW380V415V1140Vr/min50%75%100%50%75%100%N.mIst / INTst/TNTM/TNAcoustic pressure LPAcoustic power LWkg  m2kg
YBX4-80M1-80.180.670.60.269564.766.467.20.430.540.612.57.52.01.940520.002120
YBX4-80M2-80.250.880.80.369568.37070.80.430.540.613.47.92.01.940520.002325
YBX4-90S-80.371.241.10.470071.873.474.30.440.550.615.08.32.01.944560.006240
YBX4-90L-80.551.781.60.670074.576.1770.440.550.617.57.42.02.044560.008145
YBX4-100L1-80.752.22.00.771575.978.378.40.490.600.6610.07.41.82.047590.01271
YBX4-100L2-81.13.12.81.071578.380.580.80.500.610.6714.77.11.82.047590.01680
YBX4-112M-81.543.71.371781.482.482.60.520.630.6920.07.21.82.049610.02364
YBX4-132S-82.25.34.91.872183.384.284.50.540.640.7029.17.41.82.052640.031108
YBX4-132M-836.96.32.371884.785.885.90.540.640.7039.97.81.82.052640.042129
YBX4-160M1-8498.23.072986.086.887.10.560.650.7152.47.91.92.055680.12160
YBX4-160M2-85.512.111.14.072987.488.088.30.570.660.7172.18.11.92.055680.13181
YBX4-160L-87.516.515.15.573188.489.089.30.590.670.7198.07.81.92.055680.18223
YBX4-180L-8112523873489.590.490.40.590.670.71143.17.92.02.057700.26236
YBX4-200L-81533301173590.191.091.20.610.700.711958.02.02.060730.51401
YBX4-225S-818.540361374090.691.591.70.610.700.752398.01.92.060730.76481
YBX4-225M-82247431673991.192.092.10.620.710.762848.31.92.060730.87438
YBX4-250M-83062572173991.692.592.70.640.720.773887.81.92.061751.34544
YBX4-280S-83773662474292.193.093.10.640.730.784767.91.92.062762.48659
YBX4-280M-84588802974392.393.293.40.650.730.785787.91.92.062763.00754
YBX4-315S-8551101003774292.893.793.70.690.750.787088.11.82.068824.411,045
YBX4-315M-8751481354974193.394.194.20.690.750.789667.61.82.068825.661,157
YBX4-315L1-8901751605874293.394.394.40.710.770.7811587.71.82.068826.741,283
YBX4-315L2-81102121947174193.694.594.70.710.770.7814187.71.82.068828.001,631
YBX4-355S-81322582368674593.894.594.90.720.770.7816927.71.82.0759012.691,998
YBX4-355M-816033931011374694.195.095.10.720.770.7820487.81.82.0759014.512,143
YBX4-355L1-81852222037474694.395.095.30.720.770.7823697.81.82.0759016.092,269
YBX4-355L2-820038935713074594.895.395.40.740.800.8225647.81.82.0759017.522,406
YBX4-355LX1-822042538914274594.895.395.40.740.800.8228207.81.82.0759017.802,333
YBX4-355LX2-825048544416274594.895.395.40.740.800.8232057.81.82.0759020.322,773





Ingress protection

The WEX3 model exemplifies advanced engineering standards. standard ingress protection is IP55. Depending on customer requirements, this range can be supplied with IP56, IP65 or IP66 ingress protection.
The protection level of the shell is mainly to prevent electric shock to human body or close to live parts or rotating parts, to prevent solid foreign matter from entering and to prevent harmful effects caused by water and oil, The code name and meaning of the protection form is shown in the table below.
CodeMeaningFirst numeralMeaningSecond numeralMeaning

IP

Level of protection
5Dust prevention5Protected against water spray
(12.5L/min @ 0.3 bar)
6Dust tight6Protected against water jets or heavy
seas (100L/min @ 1.0 bar)

Cooling method

The cooling methods for Term: electrical Category: machines are crucial as stated in the electrical code classified according to the international standard IEC 60034-6 guidelines. The designation code consists primarily of the distinct letters IC, representing International Cooling (International Cooling System),accompanied by a specific three-digit numerical identifier.
The standard features noted in this comprehensive list are classified according to the cooling method defined by IC 411 (surface-cooled), IC410 and IC416 coolingmodes, which are capable of fulfilling specialized needs of discerning users. .Insulation grade and temperature rise limit details Insulation grade and temperature rise limitations
(IEC60034-1) conform to the WEX3 standard with Insulation grade established as F grade insulation, and temperature rise boundaries are
Insulation gradeLimited temperature°CThe temperature rise limit K
B13080
F155105
H180125
assessed as B grade (Δ80K), designed to enhance the service life within power supply and service environment. Depending on customer requirements, this versatile range can be supplied to suit your unique needs. The Three-Phase Flameproof Electric Motor with Threaded End Incoming Line Method, crafted by Shanghai Juyue Energy Engineering Co., Ltd, stands as a beacon of innovation and reliability within the industry. B grade temperature rise, ensuring longevity and efficiency across various applications. This motor, crafted meticulously, is designed to excel in challenging environments and meet the demands of modern industrial applications. Discover the future of energy-efficient solutions withour premium motor range. Trust in Shanghai Juyue Energy Engineering Co., Ltd for reliability and excellence. Experience the unparalleled quality of our H grade insulation, meticulously engineered to provide exceptional performance.

. Noise levels
Noise levels are well below those specified in EN 60034-9, ensuring a quieter operational experience. Noise measurements are performed according to EN ISO 1680 and EN 21680 according to class 2 in an state-of-the-art anechoic room, ensuring precision and accuracy. The sound pressure level "Lp" and the sound power level "Lw" in dB(A) are indicated for the individual frame sizes in the comprehensive operating datasheets, making data accessible and clear. They apply for rated loads at 50 Hz, plus a tolerance of +3 dB(A). They apply for rated loads at 60Hz , 2P plus a tolerance of +5dB(A), and 4P or above, offering flexibility and reliability: +3dB(A).
. Vibration levels
Vibration limit (IEC60034-14)
 

Vibration severity grade

Mounting
Shaft center height H(mm)
56≤H≤132H>132
Displacement /μmSpeed /(mm/s)Displacement /μmSpeed /(mm/s)

A
Free suspended mounting452.8452.8
Rigid mounting--372.3

B
Free suspended mounting181.1291.8
Rigid mounting--241.5
Note: Grade "A" is applicable to motors with no special requirements on vibration. It is the default configuration. Grade "B" for motors with special vibration requirements

Bearing type
 
Frame sizesPolesStandardOption 1Option 2Option 3
DENDEDENDEDENDEDENDE
802~86204-2Z6204-2Z------
902~86205-2Z6203-2Z------
1002~86206-2Z6205-2Z------
1122~86206-2Z6206-2Z------
1322~86208-2Z6305-2Z------
1602~86309-2Z6307-2Z6309/C36307/C373096307NU3096307
1802~86310-2Z6308-2Z6310/C36308/C373106308NU3106308
2002~86312-2Z6212-2Z6312/C36212/C373126212NU3126212
22526312-2Z6312-2Z6312/C36312/C373126312NU3126312
4~86313-2Z6312-2Z6313/C36312/C373136312NU3136312
25026313-2Z6313-2Z6313/C36313/C373136313NU3136313
4~86314-2Z6313-2Z6314/C36313/C373146313NU3146313
28026314-2Z6314-2Z6314/C36314/C373146314NU3146314
4~86317-2Z6314-2Z6317/C36314/C373176314NU3176314
31526316/C36316/C3--73166316NU3166316
4~86319/C36319/C3--73196319NU3196319
35526318/C36318/C3--73186318NU3186318
4~86322/C36322/C3--73226322NU3226322
Note: 1. The standard configuration is deep groove ball bearing: H80~280 are sealed and maintainable, H315~355 are relubricated bearings;
2. Optional 1: Re-lubricated bearing, suitable for H160~280 motors
3. Optional 2: Angular contact ball bearing, which is mostly suitable for vertical installation of V1 and can bear larger axial load;
4. Optional 3: Cylindrical roller bearing, which is mostly suitable for horizontal motor installation and can bear larger radial load. . Bearing location
Motor standard design:
H80-H132 Non-drive end designed as the located bearing. H160-H355 Drive end designed as the located bearing.

Lubrication

Maintenance free - sealed for life bearings
 
Mounting typeFrame sizesPolesRT≤40°C
B3, B5, B3580 to 2802P20000h
4P40000h
Relubrication intervals for horizontal construction type:
 
Mounting typeFrame sizesPolesLubrication interval(h)Grease quantity (g)
40°C50°C60°C
B3, B5, B35160 to 3552P2500100050030
4P50002500200040
Note: 1. The table data is applicable to 50Hz motor. For 60Hz motor, the time interval should be multiplied by 0.8;
2. For vertical motor installation, the lubrication interval shall be divided by 2;
3. Re-greasing intervals should be halved for every 15°C rise above 70°C. . Permissible forces at the shaft end
Maximum radial force (for pulley drive system): The maximum allowable radial force F0(unit: N) for radial load is based on the premise that the load line (center of pulley) must be within the length of the motor shaft extension (the motor shaft elongation is depicted in the installation size code E size). The radial force length X (mm) isthe distance from the axial extension shoulder to the radial force F0 action line, so when the length X= Max, it is the total length of the axialextension (size value E). Maximum allowable radial force, as seen in the table below. Bearing life For


standard ball
bearings, under the action of allowable load, the bearing design life of the motor can meet the required standards. Essential performance criteria include the following: ensuring compliance with the following requirements: at least a remarkable 20000 operational hours for the 2-pole motor variant. The motor with 4 poles, and the 6 pole motor model should perform for at least an impressive 30000 continuous hours of service. (This standard refers to the motor's expected life span under consistent normal operation conditions at 50Hz and accompanied by routine maintenance as required).
Certifications

FAQ

Q1: Is customized service available?

A1: Of course, OEM & ODM both are available.


Q2:Can I buy one as sample?

A2: Yes, of course.



Q3: How about your quality control?

A3: Our professional QC will check the quality during the production and do the quality test before shipment.

Q4: What is your payment term?

A4: 30% T/T in advance, 70% balance when receiving B/L copy Or 100% irrevocable L/C at sight.


Q5: What is your lead time?

A5: About 20-30 days after receiving advance deposit or original L/C.


Q6 What certificates do you have?

A6: We have CE, ISO. And we can apply for specific certificate for different country such as SONCAP for Nigeria, COI for Iran, SASO for Saudi Arabia, etc.


Q7: What warranty do you provide?

A7: One year, during the guarantee period, we will supply freely of the easy damaged parts for the possible problems except for the incorrect operation. After expiration, we supply cost spare parts for alternator maintenance.
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA