High Power Switching Power Supply Sp-15000 15000W 24V 36V 48V 60V 110V 220V AC to DC Industrial SMPS Power Supply

Price $1842.00 Compare
Min Order 1 Piece
Shipping From Zhejiang, China
Popularity 419 people viewed
Quantity
+-
 

Zhejiang Weihao Electronic Co., Ltd.

VIP   Audited Supplier 15 years
Profile Certified by SGS/BV
SP-15000
Single
15000W
Full Range
Series Switching Power Supply
Self-excited Switching Power Supply
Frequency Modulation Type
PWM
Weho
-20 - +60ºC
Current Sharingttttparallel Current Sharing
Low Than 18A
45Hz - 65Hz
95-190VAC(Output Current 50%),195-265VAC(Output Cu
PF≧0.99/230VAC(Fully Loaded)
12V 0.5A
455*345*251mm(L*W*H)
22kg
WEHO
Carton
Zhejiang
8504401400
Product Description
High Power Switching Power Supply SP-15000 15000W 24V 36V 48V 60V 110V 220V Ac to Dc Industrial Smps Power Supply

Notice:

1,Input Voltage 95V~264V

2,Protection type: short circuit/over current/over voltage/over temperature

3,Power factor PF>0.99

4,Work efficiency up to 93%

5,485 Communication Control

Detailed Photos

ModelGZN1-15000-24GZN1-15000-36GZN1-15000-48GZN1-15000-60GZN1-15000-110GZN1-15000-220
O
U
T
P
U
T
DC voltage24V    36V   48V60V110V    220V
Rated current625A    416A   312A250A   136A68A
Current  range0 -  6 2 5 A     0 - 416A     0 - 312A 0 - 250A     0 -  136A0 - 68A
Rated power15000W
Ripple &  Roise500mV  500mV  600mV    600mV   1000mV  1500mV
Constant current range12 - 24V     18 - 36V     24 - 48V 30 - 60V     55 -  110V     110 - 220V
Voltage tolerance±1.0%
Line  regulation±1.0%
Load regulation±1.0%
Setup  risetime1500mS ,700mS/ 230VAC( Full  load)
I
N
P
U
T
Voltage  range95- 190 VAC(output current 50%) , 195- 265 VAC(output current 10 0%)
Frequency range45Hz -  65Hz
Power factorPF>=0 .99/ 230VAC( Full  load)
Efficiency( MAX)    90 %  91.5 %   92 %     92 %   92.5 %     93 %
AC Current<110A
Leakage current<3 .0mA /  240VAC
PROTECTIONShort curcuitEnter the  constant  current  and  the voltage  is  less than  10%  of the  rated  voltage, turn  off  and  lock
the  output  after  1  second,  and  resume  after  restart
Over currentThe  user  can  set  a  delay  of  5  seconds  after  the  current value  is turned  off,  and the  output  can  be
restored  after  restart
Over voltageThe  user  can  set  the  overvoltage  value  to  turn  off the  output  voltage,  and  resume  after  restart
Over temperatureTurn  off the  output  and  automatically  recover  or  restart  after  the  temperature  drops
FUN
CTI
ON
Output voltage adjustment     0 -  26.4V     0 - 39.6V     0 -  52.8V 0 - 66V 0 -  121V0 - 242V
Output constant current adjustment     0 - 740A     0 - 500A     0 - 375A 0 - 300A     0 -  163.6A     0 - 81.8A
485  communicationMODBUS  Communication  protocol
Isolating auxiliary power supply12V 0.5A        ( Need to  be customized)
 Output  remote control switchDefault power on,  high power off(5V-12V)  ( Need to be customized)
Alarm outputPower  normal signal  ( Dry contact  <= 36 V , 0 . 1A )( Need to be customized)
ENV
IRO
NM
ENT
Working TEMP.-20 - +60ºC
Working humidity-20 -  90%  RHnon-condensing
Storage TEMP. and humidity-40 - +85ºC,  10 - 95%  RH  non-condensing
Vibration10 - 500Hz, 2G  10mins/T, X ,,Zaxis 60 minutes each
SAF
ETY
& E
MC
Isolation resistanceInput-output: 100 Mhms/500 VDC/ 25 ºC/70% RH
Withstand voltageI/ P-O/ P : 2KVAC  I/ P- FG:2KVAC O/ P- FG:0 . 5KVAC
OTH
ERS
Dimension455 *345 * 251mm(L*W * H)
Net weight22  KG
Remark   1 .  All  parameters NOT specially mentioned are measured at 23 0 VAC input,  rated load and 25 ºC of ambient temperature.
  2 .  Ripple &noise are measured at 20 MHz of bandwidth by using a 12 " twisted pair-wire terminated with a 0 . 1uf &47uf parallel
      capacitor.
  3. Tolerance: includes set up tolerance, line regulation and load regulation.
  4. If the input voltage is low, the output needs to be derated. For details, see the static characteristic diagram.
  5. Length of setup time is measured at cold first start,Turning ON/OFF the power supply may lead to increase of the setup time.
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA