CN8902
on Line
1year
Mechanical Instrument, Electromagnetic Instrument
Electricity
220V
40A
With LCD Display
Non-Customized
45-65Hz
0.1-1.0
RS232c
6kg
Changniu Technology
Cardboard Box
350*310*105
Hangzhou, China
Product Description
High-precision intelligent power tester for motor, pump industry
CN8902 Three-phase electrical parameter measuring instrument
The three-phase electrical parameter tester is suitable for the true RMS detection of three-phase voltage, current, power, power factor, frequency and other parameters in motors, pumps, transformers, electric power and other industries, and can be wired according to two wiring modes of three-phase three-wire system and three-phase four-wire system, and can also be used as a single-phase meter. The accuracy is 0.5 and 0.2 grades.
Tester measurement range and accuracy:

Instrument safety indicators:
1,Insulation resistance: The shell and power input are greater than 5MΩ between each other.
2,Withstand voltage: 1800V and 10mA leakage current for 2 seconds between the power input terminal and the shell.
3,Grounding: The power supply is grounded, and the resistance between the shells is less than 0.2Ω.








CN8902 Three-phase electrical parameter measuring instrument
The three-phase electrical parameter tester is suitable for the true RMS detection of three-phase voltage, current, power, power factor, frequency and other parameters in motors, pumps, transformers, electric power and other industries, and can be wired according to two wiring modes of three-phase three-wire system and three-phase four-wire system, and can also be used as a single-phase meter. The accuracy is 0.5 and 0.2 grades.
Tester measurement range and accuracy:
Measurement | Parameters | Measurement | Range | Measurement |
voltage | (10.0~500.0)V | ±(0.25%reading +0.25%range) | 0.1V | 600V |
current | (0.030~40.00)A | <10A 0.001A ≥10A 0.01 | 50A | |
Active power | It depends on the voltage current range | Factor =1.0: ±(0.25% reading +0.25%range) Factor =0.5: 0.5:±(0.5% reading +0.5%range) | <1000W 0.1W ≥1kw 10W | |
Factor | 0.20~1.00 | ±0.02 | 0.01 | |
frequency | (45~65)Hz | ±0.2 Hz | 0.1Hz |
Working conditions:
1. Temperature conditions to ensure measurement accuracy: 20°C±5°C.
2. Working temperature range: 0~40°C, air relative humidity: 30%~90%.
3. There is no corrosive and explosive gas in the room.
4. Power supply: AC220V/50Hz.
5. Fuse: 0.5A.
1. Temperature conditions to ensure measurement accuracy: 20°C±5°C.
2. Working temperature range: 0~40°C, air relative humidity: 30%~90%.
3. There is no corrosive and explosive gas in the room.
4. Power supply: AC220V/50Hz.
5. Fuse: 0.5A.

Instrument safety indicators:
1,Insulation resistance: The shell and power input are greater than 5MΩ between each other.
2,Withstand voltage: 1800V and 10mA leakage current for 2 seconds between the power input terminal and the shell.
3,Grounding: The power supply is grounded, and the resistance between the shells is less than 0.2Ω.