Features

-Adopted high permeability core , high accuracy, good linear performance;
-Anti-combustion plastics case;
-Encapsulated with epoxy resin with strong insulation ability;
-it Can be applied in Electronic electricity meters.

Specification: 

Primary current 5A or 10A
Secondary Current : 2.5mA or 4.5mA
Max Current 60A
Ratio: 2000: 1
Class : 0.1 Class
DC immune
ID : 6.8mm, width: 24mm, height : 25mm 
Pins distance : Can be customized

TOPRO 120A DC immune Current transformer (DC immune CT) DCT-04 can be used in IEC electricity meters, Conform to IEC62053-21. We adopted high quality amorphous alloy and nanocrystalline core for DC immunity Current transformer, with good linearity and high accuracy up to Class 0.2, Class 0.1 and Class 0.05.

 

Product Characteristics

1. It applied for IEC meters and ANSI meters.

2. Adopted high quality amorphous alloy and nanocrystalline core, good linearity

And high precision.

3. The CT case adopted flame retardant PBT materials, with good mechanical and electrical strength.

4. Encapsulated with epoxy resin with strong insulation ability;

5. DC immune current transformers (DCT) are used in electricity meters, under the influence quantity with DC and even harmonics in AC current circuit, the accuracy class up to 0.05 or 0.1. Conform to IEC62053-21.

6. Rosh compliance, CE certificated.

 

 

Product Dimensions

120A DC immune Current transformer DCT-04

                                 Outline dimension

                                         

 

Product Datasheet

Model

120 A DC immune Current transformer DCT-04

Rated primary current

5 Amps

Maximum primary current (Imax)

120 Amps

Secondary current (Output)

2 mA

Turn ratio

1 : 2500

DC and even harmonics

Current for direct connected meters, Imax/√2 DC error   should be less than ±3% when power factor=1.0, According to IEC 62053-21

Operating temp.

-40° C - 70° C

Storage Temp

-40° C -85° C

Core material

Nano crystalline and Amorphous

Accuracy

0.1 class

ROSH compliance

Yes