High-Precision Yokogawa Eja110e Differential Pressure Transmitter for Industrial Use

Price $476.00 Compare
Min Order 1 Piece
Shipping From Shanghai, China
Popularity 233 people viewed
Quantity
+-
 

Cold Valley Intelligent Technology (Shanghai) Co., Ltd.

VIP   Audited Supplier 1 year
Profile Certified by SGS/BV
EJA110E
Medium & High Temperature Pressure Transmitter
Diffused Silicon Pressure Transmitter
Liquid
0.1G
0.001MPa~35MPa
IP67
CE
Customized
YOKOGAWA
Wooden
China
90262010
Product Description
 
Product Description
The high performance diff erential pressure transmitter EJA110E features single crystal silicon resonant sensor and is suitable to measure liquid, gas, or steam fl ow as well as liquid level, density and pressure. EJA110E outputs a 4 to 20 mA DC signal corresponding to the measured diff erential pressure. Its accurate and stable sensor can also measure the static pressure which can be shown on the integral indicator or remotely monitored via BRAIN or HART communications. Other key features include quick response, remote set-up using communications and self-diagnostics. FOUNDATION Fieldbus, PROFIBUS PA and 1 to 5 V DC with HART (Low Power) protocol types are also available.

EJA-E series models in their standard confi guration, with the exception of the Fieldbus, PROFIBUS and Low Power types, are certifi ed as complying with SIL 2 for safety requirement.
 
 
SPAN AND RANGE LIMITS
Measurement
Span/Range 
kPa inH2O
(/D1) 
mbar
(/D3) 
mmH2O
(/D4) 
F* Span 0.5 to 5 2.0 to 20 5 to 50 50 to 500 
Range -5 to 5 -20 to 20 -50 to 50 -500 to 
500 
L* Span 0.5 to 10 2.0 to 40 5 to 100 50 to 1000 
Range -10 to 10 -40 to 40 -100 to 
100 
-1000 to 
1000 
M Span 1 to 100 4 to 400 10 to 1000 100 to 
10000 
Range -100 to 
100 
-400 to 
400 
-1000 to 
1000 
-10000 to 
10000 
H Span 5 to 500 20 to 2000 50 to 5000 0.05 to 5 
kgf/cm2 
Range -500 to 
500 
-2000 to 
2000 
-5000 to 
5000 
-5 to 5 
kgf/cm2 
V Span 0.14 to 14 
MPa 
20 to 2000 
psi 
1.4 to 140 
bar 
1.4 to 140 
kgf/cm2 
Range -0.5 to 14 
MPa 
-71 to 
2000 psi 
-5 to 140 
bar 
-5 to 140 
kgf/cm2 
Ordering Information
Model Sufx Codes Description 
EJA110E . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Diferential pressure transmitter 
Output signal -D .............................
-J .............................
-F .............................
-G.............................
-Q............................. 
4 to 20 mA DC with digital communication (BRAIN protocol)
4 to 20 mA DC with digital communication (HART 5/HART 7 protocol)*1
Digital communication (FOUNDATION Fieldbus protocol, refer to GS 01C31T02-01EN)
Digital communication (PROFIBUS PA protocol, refer to GS 01C31T04-01EN)
Low Power, 1 to 5 V DC with digital communication (HART 7 protocol) 
Measurement
span (capsule) 
F............................
L............................
M ...........................
H............................
V............................ 
0.5 to 5 kPa (2.0 to 20 inH2O) (For Wetted parts material code S)
0.5 to 10 kPa (2.0 to 40 inH2O) (For Wetted parts material code M, H, T, A, D, B and W)
1 to 100 kPa (4 to 400 inH2O)
5 to 500 kPa (20 to 2000 inH2O)
0.14 to 14 MPa (20 to 2000 psi) 
Wetted parts
material *2 
¨ ........................ Refer to "Wetted Parts Material" Table. 
Process connections
See the table in the next 
page for the codes for a 
diaphragm seal system.
 
0......................
1......................
2......................
3......................
4......................
5...................... 
without process connector (Rc1/4 female on the cover fanges)
with Rc1/4 female process connector
with Rc1/2 female process connector
with 1/4 NPT female process connector
with 1/2 NPT female process connector
without process connector (1/4 NPT female on the cover fanges) 
Bolts and nuts material J....................
G....................
C.................... 
B7 carbon steel
316L SST
660 SST 
Installation
 
-7 ................
-8 ................
-9 ................
-B ................
-U ................ 
Vertical piping, left side high pressure, and process connection downside
Horizontal piping and right side high pressure
Horizontal piping and left side high pressure
Bottom Process Connection, left side high pressure*3
Universal fange*3 
Amplifer housing 1...............
3...............
2............... 
Cast aluminum alloy
Cast aluminum alloy with corrosion resistance properties*5
ASTM CF-8M stainless steel*6 
Electrical connection
 
0............
2............
4............
5............
7............
9............
A............
C............
D............ 
G1/2 female, one electrical connection without blind plugs
1/2 NPT female, two electrical connections without blind plugs
M20 female, two electrical connections without blind plugs
G1/2 female, two electrical connections and a blind plug*7
1/2 NPT female, two electrical connections and a blind plug*7
M20 female, two electrical connections and a blind plug*7
G1/2 female, two electrical connections and a SUS316 blind plug
1/2 NPT female, two electrical connections and a SUS316 blind plug
M20 female, two electrical connections and a SUS316 blind plug 
Integral indicator
 
D.........
E.........
N......... 
Digital indicator*8
Digital indicator with the range setting switch (push button)*9
None 
Mounting bracket B......
D......
J......
K......
M .....
P......
N...... 
304 SST 2-inch pipe mounting, fat type (for horizontal piping)
304 SST 2-inch pipe mounting, L type (for vertical piping)
316 SST 2-inch pipe mounting, fat type (for horizontal piping)
316 SST 2-inch pipe mounting, L type (for vertical piping)
316 SST 2-inch pipe mounting (for bottom process connection type)
316 SST 2-inch pipe mounting, position adjustable L type (for vertical piping)*10
None 
Optional Codes ¨/ Optional specifcation 
 
Table. Wetted Parts Material
Wetted parts 
material code 
Cover fange and process 
connector 
Capsule Capsule gasket Vent/Drain plug 
S # ASTM CF-8M *1*8 Hastelloy C-276 *2 (Diaphragm)
F316L SST, 316L SST (Others) 
Tefon-coated 316L SST 316 SST 
L # ASTM CF-3M *7*8 Hastelloy C-276 *2 (Diaphragm)
F316L SST, 316L SST (Others) 
Tefon-coated 316L SST 316L SST 
H # ASTM CF-8M *1*8 Hastelloy C-276 *2 PTFE Tefon 316 SST 
M # ASTM CF-8M *1*8 Monel PTFE Tefon 316 SST 
T ASTM CF-8M *1*8 Tantalum PTFE Tefon 316 SST 
A # Hastelloy C-276 equivalent *3 Hastelloy C-276 *2 PTFE Tefon Hastelloy C-276 *2 
D Hastelloy C-276 equivalent *3 Tantalum PTFE Tefon Hastelloy C-276 *2 
B # Monel equivalent *4 Monel PTFE Tefon Monel 
W # Super Duplex SST equivalent *5 Hastelloy C-276 *2 PTFE Tefon Super Duplex SST *6 
Company Profile
Cold Valley Intelligent Technology (Shanghai) Co., Ltd. is a member enterprise of Hanshan (Cold Mountain) Intelligent Technology Co;
 (hereinafter referred to as Hanshan Intelligent Technology Co., Ltd. group) was formally established in Shanghai in 2013;
Its founding team are all from top international automation companies; have over 20 years of experience in automation industry; over 20 years of experience in automation engineering; over 10 years of experience in consulting and implementation of digital solutions; aiming at providing quality automation and digitization products and services for global customers; the company's headquarter is located in Shanghai, China;
The company has been deeply cultivated in the petrochemical industry for more than 20 years; has in-depth understanding of the automation and digitalization needs of upstream, midstream, and downstream enterprises; provides professional products and solutions based on automation and digitalization and full life cycle services for petroleum, chemicals, electric power, biomedicine, APIs, food and beverage, liquor, metallurgy, and non-ferrous metals.

FAQ
You may have this questions

How do I select the right product?
A:Upon receipt of your inquiry, we will provide you with a comprehensive technical document. This will enable you to verify the detailed process parameters and technical specifications required. Based on your specific requirements, we will then recommend the most suitable model.

I would like a confirmed model. Can you provide that?
A:Certainly. Once you send us the model you require, we will first need to verify the suitability of the model. If necessary, we will provide some more cost-effective optimization suggestions. After confirmation, we can proceed with a formal quotation.

Measurement rang
Message Type
* Message Content
* Name  
* Phone
* Email
* CAPTCHA