Dew point Analyzer
1 Year
1 Year
Brotie
Customized
Portable
FCC, CE, RoHS
O2
Electrochemical Gas Analyzer
Available
2% in Fs Range
0.01ppm
90% of Final Fs Reading in 10 Seconds
BROTIE
Carton
0-10ppm, 0-100ppm, 0-1000ppm, 0-1% O2
China
9027100090
Product Description


Features:
- New pattern, long-life, with long service life, fast response and high sensitivity;
- Sensor designed by ion current technology;
- Menu locking function provided, avoid the misoperation to change the parameters on the analyzer;
- Automatically memorizing system equipped, operation time of the analyzer will be recorded automatically ;
- Compact size, simple construction, easy on operation and after service;
It can be used in high purity oxygen production(PSA, VPSA, Cryogenic), metallurgy, health, petrochemicals, and power electronics industries.
Specifications:
Range: | 10.00%-96.00%, 10-99.00%(special model) |
Accuracy: | ±2% of FS range, ±0.2% of 80-99% |
Repeatability: | ±1% of FS range |
Principle: | Ion current technology (can service in Air and inert gases, not corrosive gases.) |
Sample gas flow speed: | 400~600ml/min |
Stability: | ±1% of FS/7d |
Response time: | 90% of FS reading in 60 seconds |
Power supply: | 220V±10%, 50/60Hz |
Signal outputs: | 4-20mA |
Expected analyzer life: | More than 5 years (in normal condition) |
Expected sensor life: | 2-3 years (in normal condition) |
Installing dimension: | W×H×D=150mm*74mm*167mm |
PUHUI High Purity Oxygen Analyzer(Professional model)
Features:
- New pattern, long-life, conversion ion current tester with fast response and high sensitivity;
- A standard RS232C interface;
- Setting alarm value and contact output value arbitrarily;
- High precision, automatic temperature compensation, eliminating the impact of environmental temperature;
- Setting upper and lower alarm values arbitrarily during the measurement range;
It can be used in high purity oxygen production, metallurgy, health, petrochemicals, and power electronics industries.
Specifications:
Range: | 10-99.99%/50-99.99%/90-99.99%/97%-99.99%O2;auto-ranging |
Accuracy: | ±0.5% of FS range, ±0.1% of 90-99.99% |
Repeatability: | Cv≤0.5% |
Preheating time: | 300s |
Sample gas flow speed: | 150~300ml/min |
Stability: | zero drift ≤0.5% of FS/7d , span drift ≤0.5% of FS/7d |
Response time: | 90% of FS reading in 15 seconds |
Sensitivity: | 0.01% O2 |
Power supply: | 85-265 VAC, 50/60Hz, power loss≤6w |
Signal outputs: | 4-20mA or 0-5V DC isolated |
Contact capacity: | 125VAC 0.3A, 110VDC 0.3A, 30VDC 1A |
Expected sensor life: | 3 years (in normal condition) |
Installing dimension: | W×H×D=92mm*92mm*110mm |